Mechanical properties of anterior lens capsule assessed with AFM and nanoindenter in relation to human aging, pseudoexfoliation syndrome, and trypan blue staining

被引:10
|
作者
Efremov, Yuri M. [1 ]
Bakhchieva, Natalia A. [2 ]
Shavkuta, Boris S. [1 ,3 ]
Frolova, Anastasia A. [1 ]
Kotova, Svetlana L. [1 ,4 ]
Novikov, Ivan A. [2 ]
Akovantseva, Anastasia A. [1 ]
Avetisov, Konstantin S. [2 ]
Avetisov, Sergei E. [2 ,5 ]
Timashev, Peter S. [1 ,3 ,4 ,6 ]
机构
[1] Sechenov Univ, Inst Regenerat Med, 8 Trubetskaya St, Moscow 119991, Russia
[2] Res Inst Eye Dis, 11 Rossolimo St, Moscow 119021, Russia
[3] Russian Acad Sci, Fed Sci Res Ctr Crystallog & Photon, Inst Photon Technol, Pionerskaya 2, Moscow 108840, Russia
[4] NN Semenov Inst Chem Phys, 4 Kosygin St, Moscow 119991, Russia
[5] Sechenov Univ, 2 Bolshaya Pirogovskaya St,Bldg 4, Moscow 119991, Russia
[6] Lomonosov Moscow State Univ, Chem Dept, Leninskiye Gory 1-3, Moscow 119991, Russia
基金
俄罗斯科学基金会;
关键词
Lens capsule; Biomechanics; Young's modulus; Atomic force microscopy; Capsulorhexis; Cataract; Pseudoexfoliation syndrome (PEX); Trypan blue staining; ATOMIC-FORCE MICROSCOPY; ELASTIC-MODULUS; CATARACT-SURGERY; STIFFNESS; RESISTANCE;
D O I
10.1016/j.jmbbm.2020.104081
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is the mechanical characterization of the mid-to- old-age human anterior lens capsules (ALCs) obtained by capsulorhexis using Atomic Force Microscopy (AFM) and a nanoindenter at different spatial scales. The dependencies on the human age, presence or absence of pseudoexfoliation syndrome (PEX), and application of trypan blue staining during the surgery were analyzed. The measurements on both the anterior (AS) and epithelial (ES) sides of the ALC were conducted and the effect of cells present on the epithelial side was carefully accounted for. The ES of the ALC had a homogenous distribution of the Young's modulus over the surface as shown by the macroscale mapping with the nanoindenter and local AFM indentations, while the AS was more heterogeneous. Age-related changes were assessed in groups ranging from the mid-age (from 48 years) to old-age (up to 93 years). We found that the ES was always stiffer than the AS, and this difference decreased with age due to a gradual decrease in the Young's modulus of the ES and an increase in the modulus of the AS. No significant changes were found in the mechanical properties of ALCs of PEX patients versus the PEX-free group, as well as in the properties of the ALC with and without trypan blue staining.
引用
收藏
页数:8
相关论文
共 10 条
  • [1] Comparison of the mechanical properties of the anterior lens capsule in senile cataract, senile cataract with trypan blue application, and pseudoexfoliation syndrome
    Simsek, Cem
    Oto, Sibel
    Yilmaz, Gursel
    Altinors, Dilek Dursun
    Akman, Ahmet
    Gungor, Sirel Gur
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (08): : 1054 - 1061
  • [2] Evaluation of mechanical resistance to tearing of the anterior lens capsule after staining with different concentrations of trypan blue
    Sandor, Gabor L.
    Kiss, Zoltan
    Bocskai, Zoltan I.
    Toth, Gabor
    Temesi, Tamas
    Nagy, Zoltan Z.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 293 - 297
  • [3] Anterior lens capsule has more affinity to trypan blue in patients with pseudoexfoliation
    Hosseini, H.
    Nowroozzadeh, M. H.
    Razeghinejad, M. R.
    Ashraf, H.
    Salouti, R.
    Ashraf, M. J.
    EYE, 2011, 25 (09) : 1245 - 1246
  • [4] Staining of anterior lens capsule with Trypan blue for better visualization of capsulorhexis in surgery of mature cataracts
    Melles, GRJ
    de Waard, PWT
    Pameijer, JH
    Beekhuis, WH
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 215 (06) : 342 - 344
  • [5] The effects of vital dyes on mechanical properties of the human anterior lens capsule
    Simsek, Cem
    Gokmen, Onur
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (01) : 66 - 70
  • [6] Regional mechanical properties and stress analysis of the human anterior lens capsule
    Pedrigi, R. M.
    David, G.
    Dziezyc, J.
    Humphrey, J. D.
    VISION RESEARCH, 2007, 47 (13) : 1781 - 1789
  • [7] Comparison of trypan blue and Brilliant Blue G for staining of the anterior lens capsule during cataract surgery: short-term results
    Nagashima, Takamitsu
    Yuda, Kentaro
    Hayashi, Takahiko
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (01) : 33 - 39
  • [8] Comparison of trypan blue and Brilliant Blue G for staining of the anterior lens capsule during cataract surgery: short-term results
    Takamitsu Nagashima
    Kentaro Yuda
    Takahiko Hayashi
    International Ophthalmology, 2019, 39 : 33 - 39
  • [9] Altered mechanical behavior and properties of the human anterior lens capsule after cataract surgery
    Pedrigi, R. M.
    Dziezyc, J.
    Humphrey, J. D.
    EXPERIMENTAL EYE RESEARCH, 2009, 89 (04) : 575 - 580
  • [10] Methyl blue and aniline blue versus patent blue and trypan blue as vital dyes in cataract surgery: Capsule staining properties and cytotoxicity to human cultured corneal endothelial cells
    Thaler, Sebastian
    Hofmann, Johanna
    Bartz-Schmidt, Karl-Ulrich
    Schuettauf, Frank
    Haritoglou, Christos
    Yoeruek, Efdal
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1147 - 1153