Extending immunofluorescence detection limits in whole paraffin-embedded formalin fixed tissues using hyperspectral confocal fluorescence imaging

被引:13
作者
Constantinou, P. [1 ]
Dacosta, R. S. [1 ]
Wilson, B. C. [1 ]
机构
[1] Univ Toronto, Ontario Canc Inst, Dept Med Phys, Toronto, ON, Canada
关键词
Autofluorescence; confocal; flavin; fluorescence; hyperspectral; linear unmixing; AUTOFLUORESCENCE; CONSTRUCTION; MICROSCOPY;
D O I
10.1111/j.1365-2818.2009.03155.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A major problem in microscopic imaging of ex vivo tissue sections stained with fluorescent agents (e.g. antibodies, peptides) is the confounding presence of background tissue autofluorescence. Autofluorescence limits (1) the accuracy of differentiating background signals from single and multiple fluorescence labels and (2) reliable quantification of fluorescent signals. Advanced techniques such as hyperspectral imaging and spectral unmixing can be applied to essentially remove this autofluorescent signal contribution, and this work attempts to quantify the effectiveness of autofluorescence spectral unmixing in a tumour xenograft model. Whole-specimen single-channel fluorescence images were acquired using excitation wavelengths of 488 nm (producing high autofluorescence) and 568 nm (producing negligible autofluorescence). These single-channel data sets are quantified against hyperspectral images acquired at 488 nm using a prototype whole-slide hyperspectral fluorescence scanner developed in our facility. The development and further refinement of this instrument will improve the quantification of weak fluorescent signals in fluorescence microscopy studies of ex vivo tissues in both preclinical and clinical applications.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 17 条
[1]   CELLULAR AUTOFLUORESCENCE - IS IT DUE TO FLAVINS [J].
BENSON, RC ;
MEYER, RA ;
ZARUBA, ME ;
MCKHANN, GM .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) :44-48
[2]   Imaging of whole tumor cut sections using a novel scanning beam confocal fluorescence MACROscope® [J].
Constantinou, P ;
Vukovic, V ;
Haugland, HK ;
Nicklee, T ;
Hedley, DW ;
Wilson, BC .
JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (03) :326-331
[3]  
CONSTANTINOU P, 2005, J SELECT TOPICS QUAN, V4, P766
[4]  
DaCosta RS, 2003, PHOTOCHEM PHOTOBIOL, V78, P384, DOI 10.1562/0031-8655(2003)078<0384:MFEMRT>2.0.CO
[5]  
2
[6]  
Dixon A E, 2001, Methods Mol Biol, V170, P237
[7]   Application of spectral imaging microscopy in cytomics and fluorescence resonance energy transfer (FRET) analysis [J].
Ecker, RC ;
de Martin, R ;
Steiner, GE ;
Schmid, JA .
CYTOMETRY PART A, 2004, 59A (02) :172-181
[8]   The histological basis of detection of adenoma and cancer in the colon by autofluorescence endoscopic imaging [J].
Izuishi, K ;
Tajiri, H ;
Fujii, T ;
Boku, N ;
Ohtsu, A ;
Ohnishi, T ;
Ryu, M ;
Kinoshita, T ;
Yoshida, S .
ENDOSCOPY, 1999, 31 (07) :511-516
[9]   A phase II trial with pharmacodynamic endpoints of the proteasome inhibitor bortezomib in patients with metastatic colorectal cancer [J].
Mackay, H ;
Hedley, D ;
Major, P ;
Townsley, C ;
Mackenzie, M ;
Vincent, M ;
Degendorfer, P ;
Tsao, MS ;
Nicklee, T ;
Birle, D ;
Wright, J ;
Siu, L ;
Moore, M ;
Oza, A .
CLINICAL CANCER RESEARCH, 2005, 11 (15) :5526-5533
[10]  
Safavy A, 1999, CLIN CANCER RES, V5, p2994S