Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

被引:20
|
作者
Kang, Sung Yong [1 ]
Hong, Samin [1 ]
Bin Won, Jung [1 ]
Seong, Gong Je [1 ]
Kim, Chan Yun [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul 120752, South Korea
关键词
Angle-closure; cataract; glaucoma; intraocular lens; OCULAR DIMENSIONS; EYES; TRABECULECTOMY; DEPTH;
D O I
10.3349/ymj.2009.50.2.206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To assess the accuracy of intraocular lens (IOL) power predictions for cataract surgery in eyes with primary angle-closure glaucoma (ACG). Because of shifting of the capsular bag apparatus and shortening of the axial length, preoperative calculation of IOL power may be inaccurate for eyes with ACG. Materials and Methods: This retrospective comparative case series comprised of 42 eyes from 42 patients with primary ACG and 45 eyes from 45 subjects with normal open-angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, lens thickness, and axial length were compared. Using the SRK-II formula, the powers of the implanted IOL and the actual postoperative spherical equivalent (SE) refractive errors were compared between the two groups. Also, the absolute values of differences between predicted and residual SE refractive errors were also analyzed for each group. Results: In ACG patients, anterior chamber depth and axial length were shorter and the lens was thicker than normal controls (all p < 0.001). Even though residual SE refractive error was not significantly different (p = 0.290), the absolute value of the difference between predicted and residual SE refractive error was 0.64 +/- 0.50 diopters in AGC patients and 0.39 +/- 0.36 diopters in control subjects (p = 0.012). The number of eyes that resulted in inaccurate IOL power predictions of more than 0.5 diopters were 21 (50.00%) in the ACG group, but only 12 (26.67%) in the control group (p = 0.043). Conclusion: IOL power predictions for cataract surgery in ACG patients can be inaccurate, and it may be associated with their unique anterior segment anatomy.
引用
收藏
页码:206 / 210
页数:5
相关论文
共 50 条
  • [21] Accuracy of intraocular lens power calculation in primary angle-closure disease: comparison of 7 formulas
    Hou, Min
    Ding, Yujie
    Liu, Liangping
    Li, Jianbing
    Liu, Xing
    Wu, Mingxing
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (12) : 3739 - 3747
  • [22] Comparison of phacotrabeculectomy and sequential surgery in the treatment of chronic angle-closure glaucoma coexisted with cataract
    Li, Hai-Jun
    Xuan, Jie
    Zhu, Xiao-Min
    Xie, Lin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (05) : 687 - 692
  • [23] Ultrasound Biomicroscopic Diagnosis of Angle-closure Mechanisms in Vietnamese Subjects With Unilateral Angle-closure Glaucoma
    Tan Do
    Hiep Nguyen Xuan
    Huong Dao Lam
    Dat Tran Tien
    Giang Nguyen Thi Thuy
    Hien Nguyen Do Ngoc
    Verma, Sushma
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2018, 27 (02) : 115 - 120
  • [24] Endoscope-assisted goniosynechialysis combined with phacoemulsification and intraocular lens implantation to manage primary angle-closure glaucoma
    Jing Chen
    Yu-Ping Zou
    International Journal of Ophthalmology, 2013, (02) : 174 - 177
  • [25] New Management of Angle-closure Glaucoma by Phacoemulsification with Foldable Posterior Chamber Intraocular Lens Implantation
    Jian Ge Yan Guo Yizhi Liu Mingkai Lin Yehong Zhuo Bing Chen Xiuqi ChenZhongshan Ophthalmic Center Sun Yatsen University of Medical Sciences Guangzhou China
    眼科学报, 2000, (01) : 22 - 28
  • [26] Preliminary outcomes of primary phacoemulsification plus intraocular lens implantation for primary angle-closure glaucoma
    Hata, Hiroko
    Yamane, Shinta
    Hata, So
    Shiota, Hiroshi
    JOURNAL OF MEDICAL INVESTIGATION, 2008, 55 (3-4) : 287 - 291
  • [27] The Impact of Lens Vault on Visual Acuity and Refractive Error: Implications for Management of Primary Angle-closure Glaucoma
    Nongpiur, Monisha E.
    Singhal, Shweta
    Stewart, Stephen
    Htoon, Hla M.
    Narayanaswamy, Arun K.
    Wong, Tien Y.
    Perera, Shamira A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2016, 25 (03) : E236 - E240
  • [28] Angle-closure Glaucoma
    Nuessle, Simone
    Lubke, Jan
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023, 240 (08) : 1017 - 1032
  • [29] The efficacy of ultrasonic emulsification with IOL implantation in patients with primary angle-closure glaucoma combined with cataract
    Tang, Liqin
    Zhang, Miaoying
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (07): : 7874 - 7881
  • [30] Clear lens extraction in eyes with primary angle closure and primary angle-closure glaucoma
    Costa, Vital P.
    Leung, Christopher K. S.
    Kook, Michael S.
    Lin, Shan C.
    SURVEY OF OPHTHALMOLOGY, 2020, 65 (06) : 662 - 674