Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

被引:20
|
作者
Kang, Sung Yong [1 ]
Hong, Samin [1 ]
Bin Won, Jung [1 ]
Seong, Gong Je [1 ]
Kim, Chan Yun [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul 120752, South Korea
关键词
Angle-closure; cataract; glaucoma; intraocular lens; OCULAR DIMENSIONS; EYES; TRABECULECTOMY; DEPTH;
D O I
10.3349/ymj.2009.50.2.206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To assess the accuracy of intraocular lens (IOL) power predictions for cataract surgery in eyes with primary angle-closure glaucoma (ACG). Because of shifting of the capsular bag apparatus and shortening of the axial length, preoperative calculation of IOL power may be inaccurate for eyes with ACG. Materials and Methods: This retrospective comparative case series comprised of 42 eyes from 42 patients with primary ACG and 45 eyes from 45 subjects with normal open-angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, lens thickness, and axial length were compared. Using the SRK-II formula, the powers of the implanted IOL and the actual postoperative spherical equivalent (SE) refractive errors were compared between the two groups. Also, the absolute values of differences between predicted and residual SE refractive errors were also analyzed for each group. Results: In ACG patients, anterior chamber depth and axial length were shorter and the lens was thicker than normal controls (all p < 0.001). Even though residual SE refractive error was not significantly different (p = 0.290), the absolute value of the difference between predicted and residual SE refractive error was 0.64 +/- 0.50 diopters in AGC patients and 0.39 +/- 0.36 diopters in control subjects (p = 0.012). The number of eyes that resulted in inaccurate IOL power predictions of more than 0.5 diopters were 21 (50.00%) in the ACG group, but only 12 (26.67%) in the control group (p = 0.043). Conclusion: IOL power predictions for cataract surgery in ACG patients can be inaccurate, and it may be associated with their unique anterior segment anatomy.
引用
收藏
页码:206 / 210
页数:5
相关论文
共 50 条
  • [1] Risk Factors of Disease Progression After Cataract Surgery in Chronic Angle-closure Glaucoma Patients
    Lee, Chang Kyu
    Lee, Na Eun
    Hong, Samin
    Kang, Eunmin
    Rho, Seung Soo
    Seong, Gong Je
    Hong, Young Jae
    Kim, Chan Yun
    JOURNAL OF GLAUCOMA, 2016, 25 (04) : E372 - E376
  • [2] Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial
    Rhiu, Soolienah
    Lee, Eun Suk
    Kim, Tae-im
    Lee, Hye Sun
    Kim, Chan Yun
    ACTA OPHTHALMOLOGICA, 2012, 90 (08) : e580 - e585
  • [3] Cataract Surgery (Phacoemulsification with Intraocular Lens Implantation) Combined with Endoscopic Goniosynechialysis for Advanced Primary Angle-Closure Glaucoma
    Qian, Zhenbin
    Huang, Jinhai
    Song, Benhao
    Wei, Liqing
    Fu, Lin
    Austin, W. Michael
    Spaeth, L. George
    Pan, Weihua
    McAlinden, Colm
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (04): : 365 - 372
  • [4] Clear lens extraction in angle-closure glaucoma patients
    Barbosa, Diego T. Q.
    Levison, Ashleigh L.
    Lin, Shan C.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (03) : 406 - 408
  • [5] Endoscope-assisted goniosynechialysis combined with phacoemulsification and intraocular lens implantation to manage primary angle-closure glaucoma
    Chen, Jing
    Zou, Yu-Ping
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (02) : 174 - 177
  • [6] Verification of a formula developed to predict the postoperative intraocular pressure after cataract surgery in primary angle-closure glaucoma
    Chang, Yu-Fan
    Ko, Yu-Chieh
    Lau, Ling-Ing
    Liu, Catherine Jui-Ling
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2016, 79 (12) : 672 - 677
  • [7] Effects of phacoemulsification and intraocular lens implantation combined with ciliarotomy in the treatment of angle-closure glaucoma with cataract
    Li, Bo
    Wang, Feng-Yun
    Lv, Tai-Liang
    Zhu, Yu
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (04) : 2501 - 2504
  • [8] Angle-closure glaucoma after piggyback intraocular lens implantation
    Garcia-Feijoo, J.
    Saenz-Frances, F.
    Martinez-De-La-Casa, J. M.
    Mendez-Hernandez, C.
    Fernandez-Vidal, A.
    Elias-De-Tejada, M.
    Reche-Frutos, J.
    Garcia-Sanchez, J.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (05) : 822 - 826
  • [9] Comparison of Combined Phacoemulsification, Intraocular Lens Implantation, and Goniosynechialysis With Phacotrabeculectomy in the Treatment of Primary Angle-Closure Glaucoma and Cataract
    Zhao, Xiao-jing
    Yang, Xiu-xia
    Fan, Yun-ping
    Li, Bin-hui
    Li, Qin
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2013, 2 (05): : 286 - 290
  • [10] Comparison of two formulas for calculating intraocular lens in patients with angle-closure glaucoma
    Ji, Zhen
    Ma, Jing
    Sun, Zhonghua
    Zhang, Miaomiao
    MEDICINE, 2024, 103 (45) : e40387