Comparison of different contactless conductivity detectors for the determination of small inorganic ions by capillary electrophoresis

被引:31
|
作者
Kuban, Pavel
Evenhuis, Christopher J.
Macka, Mirek
Haddad, Paul R.
Hauser, Peter C.
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
[2] Univ Tasmania, Fac Sci Engn & Technol, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
capillary electrophoresis; contactless conductivity detection; detectors; inorganic ions;
D O I
10.1002/elan.200603528
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical performance parameters of four different contactless conductivity detectors for capillary electrophoresis were determined. These detectors were designed either with a miniature cell for versatility, with high voltage excitation for high sensitivity or with a battery power supply for field application. One of the units is commercially available. The plate numbers and reproducibility of peak areas (typically about 2%) were very similar, indicating that these parameters are generally limited by the separation and injection procedures rather than the detectors. The linear dynamic ranges are better than 2 orders of magnitude for all detectors and the correlation coefficients were also almost identical. Significant differences were found with regard to the detection limits. For the detector with a miniature cell, which lacks an in-cell amplifier, the detection limit was typically 1.5 mu M for the inorganic ions tested (K+, Ca2+, Na+, Mg2+, Li+, Cl-, NO3 and SO42-), while with the other 3 detectors this parameter was as low as about 0.1 mu M. The use of buffer solutions with relatively high background conductivity was found to lead to detection limits which were up to one order of magnitude higher. The extent of deterioration of this parameter with buffer conductivity was found to be related to the excitation voltage and was most pronounced for the high voltage detector.
引用
收藏
页码:1289 / 1296
页数:8
相关论文
共 50 条
  • [31] Considerations on contactless conductivity detection in capillary electrophoresis
    Baltussen, E
    Guijt, RM
    van der Steen, G
    Laugere, F
    Baltussen, S
    van Dedem, GWK
    ELECTROPHORESIS, 2002, 23 (17) : 2888 - 2893
  • [32] Application of a contactless conductivity detector to the determination of inorganic ions in ion chromatography
    Kubán, P
    Müri, MA
    Hauser, PC
    ANALYST, 2004, 129 (01) : 82 - 86
  • [33] Detection of inorganic ions on a capillary electrophoresis microchip using a conductivity technique
    Petkovic-Duran, K.
    Zhu, Y.
    Swallow, A.
    Noui-Mehidi, N.
    Leech, P.
    Glenn, F.
    BIOMEDICAL APPLICATIONS OF MICRO- AND NANOENGINEERING III, 2007, 6416
  • [34] Capillary electrophoresis with contactless conductivity detection for the determination of carnitine and acylcarnitines in clinical samples
    Pormsila, Worapan
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 921 - 926
  • [35] Determination of inorganic ions in explosive residues by capillary zone electrophoresis
    Feng Junhe
    Guo Baoyuan
    Lin Jin-Ming
    Xu Jianzhong
    Zhou Hong
    Sun Yuyou
    Liu Yao
    Quan Yangke
    Lu Xiaoming
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (06) : 667 - 671
  • [36] Determination of carnitine in food and food supplements by capillary electrophoresis with contactless conductivity detection
    Pormsila, Worapan
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    ELECTROPHORESIS, 2010, 31 (13) : 2186 - 2191
  • [37] Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector
    Shen, Dazhong
    Li, Yaolong
    Zhang, Zhenli
    Zhang, Ping
    Kang, Qi
    TALANTA, 2013, 104 : 39 - 43
  • [38] Capillary electrophoresis with contactless conductivity detection for uric acid determination in biological fluids
    Pormsila, Worapan
    Krahenbuehl, Stephan
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2009, 636 (02) : 224 - 228
  • [39] Analysis of inorganic and small organic ions with the capillary electrophoresis microchip
    Willauer, HD
    Collins, GE
    ELECTROPHORESIS, 2003, 24 (12-13) : 2193 - 2207
  • [40] Determination of heavy metal ions by capillary electrophoresis with contactless conductivity detection after field-amplified sample injection
    Tan, F
    Yang, BC
    Guan, YF
    ANALYTICAL SCIENCES, 2005, 21 (08) : 955 - 958