PROGRESS TOWARD A PROTON COMPUTED TOMOGRAPHY APPARATUS

被引:0
作者
Menichelli, D. [1 ]
Valentini, S. [1 ]
Bruzzi, M. [1 ]
Bucciolini, M. [1 ]
Capineri, L. [1 ]
Marrazzo, L. [1 ]
Talamonti, C. [1 ]
Tesi, M. [1 ]
Brianzi, M. [2 ]
Civinini, C. [2 ]
Lo Presti, D. [3 ]
Candiano, G.
Cirrone, G. A. P. [4 ]
Cuttone, G. [4 ]
Randazzo, N. [4 ,5 ]
Russo, M. [5 ]
Fucile, A. [5 ]
Sipala, V. [5 ]
机构
[1] Univ Florence, I-50121 Florence, Italy
[2] Ist Nazl Fis Nucl, Sezione Firenze, Florence, Italy
[3] Univ Degli Studi Catania, Catania, Italy
[4] Ist Nazl Fis Nucl, Lab Nazl Sud, Catania, Italy
[5] Ist Nazl Fis Nucl, Sezione Catania, Catania, Italy
来源
PROCEEDINGS OF THE 13TH ITALIAN CONFERENCE ON SENSORS AND MICROSYSTEMS | 2009年
关键词
RADIOGRAPHY; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There is today a growing up interest in proton therapy for tumors treatment, because these particles permit to tightly shape the dose to the target. Anyway, the spatial accuracy of proton therapy is limited by the uncertainty in stopping power distribution, which is calculated from the photon attenuation coefficients measured by X-ray tomography. A proton computed tomography apparatus (pCT) could be used to directly measure stopping power and reduce this uncertainty. Single proton tracking is a promising way to face difficulties due to multiple Coulomb scattering. The design of a proton radiography (pCR) prototype and its practical realization are described in this paper. The prototype is based on a silicon microstrip tracker to characterize particle trajectory and on a segmented YAG:Ce calorimeter to measure their residual energy. The aim is to detect protons with initial kinetic energy K=250-270 MeV and with a particle rate of similar to 1MHz. This prototype is the first step toward the design of a complete pCT system to measure tissue electron density with an accuracy better than 1% and with a spatial resolution better than 1 mm.
引用
收藏
页码:271 / +
页数:2
相关论文
共 50 条
[21]   Total variation superiorization schemes in proton computed tomography image reconstruction [J].
Penfold, S. N. ;
Schulte, R. W. ;
Censor, Y. ;
Rosenfeld, A. B. .
MEDICAL PHYSICS, 2010, 37 (11) :5887-5895
[22]   Characterization of a Silicon Strip Detector and a YAG:Ce Calorimeter for a Proton Computed Radiography Apparatus [J].
Menichelli, David ;
Bruzzi, Mara ;
Bucciolini, Marta ;
Candiano, Giuliana ;
Cirrone, Giuseppe A. Pablo ;
Capineri, Lorenzo ;
Civinini, Carlo ;
Cuttone, Giacomo ;
Lo Presti, Domenico ;
Marrazzo, Livia ;
Pallotta, Stefania ;
Randazzo, Nunzio ;
Sipala, Valeria ;
Talamonti, Cinzia ;
Valentini, Samuela ;
Pieri, Stefano ;
Reggioli, Valentina ;
Brianzi, Mirko ;
Tesi, Mauro .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) :8-16
[23]   A reconstruction approach for proton computed tomography by modeling the integral depth dose of the scanning proton pencil beam [J].
Chen, Xinyuan ;
Medrano, Maria ;
Sun, Baozhou ;
Hao, Yao ;
Reynoso, Francisco J. ;
Darafsheh, Arash ;
Yang, Deshan ;
Zhang, Tiezhi ;
Zhao, Tianyu .
MEDICAL PHYSICS, 2022, 49 (04) :2602-2620
[24]   Proton computed tomography using a 1D silicon diode array [J].
Wang, Peng ;
Cammin, Jochen ;
Bisello, Francesca ;
Solberg, Timothy D. ;
McDonough, James E. ;
Zhu, Timothy C. ;
Menichelli, David ;
Teo, Boon-Keng Kevin .
MEDICAL PHYSICS, 2016, 43 (10) :5758-5766
[25]   Comparative accuracy and resolution assessment of two prototype proton computed tomography scanners [J].
Dedes, George ;
Drosten, Hubertus ;
Goetz, Stefanie ;
Dickmann, Jannis ;
Sarosiek, Christina ;
Pankuch, Mark ;
Krah, Nils ;
Rit, Simon ;
Bashkirov, Vladimir ;
Schulte, Reinhard W. ;
Johnson, Robert P. ;
Parodi, Katia ;
DeJongh, Ethan ;
Landry, Guillaume .
MEDICAL PHYSICS, 2022, 49 (07) :4671-4681
[26]   CMOS Active Pixel Sensors as energy-range detectors for proton Computed Tomography [J].
Esposito, M. ;
Anaxagoras, T. ;
Evans, P. M. ;
Green, S. ;
Manolopoulos, S. ;
Nieto-Camero, J. ;
Parker, D. J. ;
Poludniowski, G. ;
Price, T. ;
Waltham, C. ;
Allinson, N. M. .
JOURNAL OF INSTRUMENTATION, 2015, 10
[27]   An experimental demonstration of a new type of proton computed tomography using a novel silicon tracking detector [J].
Taylor, J. T. ;
Poludniowski, G. ;
Price, T. ;
Waltham, C. ;
Allport, P. P. ;
Casse, G. L. ;
Esposito, M. ;
Evans, P. M. ;
Green, S. ;
Manger, S. ;
Manolopoulos, S. ;
Nieto-Camero, J. ;
Parker, D. J. ;
Symons, J. ;
Allinson, N. M. .
MEDICAL PHYSICS, 2016, 43 (11) :6129-6136
[28]   Colonography by computed tomography [J].
Florie, J ;
van Gelder, RE ;
Stoker, J .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2005, 17 (08) :809-813
[29]   A novel design of proton computed tomography detected by multiple-layer ionization chamber with strip chambers: A feasibility study with Monte Carlo simulation [J].
Chen, Xinyuan ;
Liu, Ruirui ;
Zhou, Shuang ;
Sun, Baozhou ;
Reynoso, Francisco J. ;
Mutic, Sasa ;
Zhang, Tiezhi ;
Zhao, Tianyu .
MEDICAL PHYSICS, 2020, 47 (02) :614-625
[30]   Calibrated uncertainty estimation for interpretable proton computed tomography image correction using Bayesian deep learning [J].
Nomura, Yusuke ;
Tanaka, Sodai ;
Wang, Jeff ;
Shirato, Hiroki ;
Shimizu, Shinichi ;
Xing, Lei .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06)