PROGRESS TOWARD A PROTON COMPUTED TOMOGRAPHY APPARATUS

被引:0
作者
Menichelli, D. [1 ]
Valentini, S. [1 ]
Bruzzi, M. [1 ]
Bucciolini, M. [1 ]
Capineri, L. [1 ]
Marrazzo, L. [1 ]
Talamonti, C. [1 ]
Tesi, M. [1 ]
Brianzi, M. [2 ]
Civinini, C. [2 ]
Lo Presti, D. [3 ]
Candiano, G.
Cirrone, G. A. P. [4 ]
Cuttone, G. [4 ]
Randazzo, N. [4 ,5 ]
Russo, M. [5 ]
Fucile, A. [5 ]
Sipala, V. [5 ]
机构
[1] Univ Florence, I-50121 Florence, Italy
[2] Ist Nazl Fis Nucl, Sezione Firenze, Florence, Italy
[3] Univ Degli Studi Catania, Catania, Italy
[4] Ist Nazl Fis Nucl, Lab Nazl Sud, Catania, Italy
[5] Ist Nazl Fis Nucl, Sezione Catania, Catania, Italy
来源
PROCEEDINGS OF THE 13TH ITALIAN CONFERENCE ON SENSORS AND MICROSYSTEMS | 2009年
关键词
RADIOGRAPHY; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There is today a growing up interest in proton therapy for tumors treatment, because these particles permit to tightly shape the dose to the target. Anyway, the spatial accuracy of proton therapy is limited by the uncertainty in stopping power distribution, which is calculated from the photon attenuation coefficients measured by X-ray tomography. A proton computed tomography apparatus (pCT) could be used to directly measure stopping power and reduce this uncertainty. Single proton tracking is a promising way to face difficulties due to multiple Coulomb scattering. The design of a proton radiography (pCR) prototype and its practical realization are described in this paper. The prototype is based on a silicon microstrip tracker to characterize particle trajectory and on a segmented YAG:Ce calorimeter to measure their residual energy. The aim is to detect protons with initial kinetic energy K=250-270 MeV and with a particle rate of similar to 1MHz. This prototype is the first step toward the design of a complete pCT system to measure tissue electron density with an accuracy better than 1% and with a spatial resolution better than 1 mm.
引用
收藏
页码:271 / +
页数:2
相关论文
共 50 条
  • [1] The PRIMA (PRoton IMAging) collaboration: Development of a proton Computed Tomography apparatus
    Scaringella, M.
    Brianzi, M.
    Bruzzi, M.
    Bucciolini, M.
    Carpinelli, M.
    Cirrone, G. A. P.
    Civinini, C.
    Cuttone, G.
    Lo Presti, D.
    Pallotta, S.
    Pugliatti, C.
    Randazzo, N.
    Romano, F.
    Sipala, V.
    Stancampiano, C.
    Talamonti, C.
    Tesi, M.
    Vanzi, E.
    Zani, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 730 : 178 - 183
  • [2] Proton computed tomography
    Bucciantonio, Martina
    Sauli, Fabio
    MODERN PHYSICS LETTERS A, 2015, 30 (17)
  • [3] Development of a Proton Computed Radiography Apparatus
    Menichelli, David
    Bruzzi, Mara
    Bucciolini, Marta
    Candiano, Giuliana
    Cirrone, Giulio A. P.
    Cuttone, Giacomo
    Capineri, Lorenzo
    Civinini, Carlo
    Lo Presti, Domenico
    Marrazzo, Livia
    Randazzo, Nunzio
    Sipala, Valeria
    Talamonti, Cinzia
    Valentini, Samuela
    Pieri, Stefano
    Reggioli, Valentina
    Brianzi, Mirko
    Tesi, Mauro
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5551 - +
  • [4] Advanced proton imaging in computed tomography
    Mattiazzo, S.
    Bisello, D.
    Giubilato, P.
    Pantano, D.
    Pozzobon, N.
    Snoeys, W.
    Wyss, J.
    RADIATION PROTECTION DOSIMETRY, 2015, 166 (1-4) : 388 - 392
  • [5] ON SOME ERRORS AND BIAS IN PROTON COMPUTED TOMOGRAPHY
    Erdelyi, Bela
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2011, 26 (10-11): : 1761 - 1774
  • [6] Proton computed tomography images with algebraic reconstruction
    Bruzzi, M.
    Civinini, C.
    Scaringella, M.
    Bonanno, D.
    Brianzi, M.
    Carpinelli, M.
    Cirrone, G. A. P.
    Cuttone, G.
    Lo Presti, D.
    Maccioni, G.
    Pallotta, S.
    Randazzo, N.
    Romano, F.
    Sipala, V.
    Talamonti, C.
    Vanzi, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 : 652 - 655
  • [7] Electron density uncertainties in proton computed tomography
    Erdelyi, B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23) : 7121 - 7134
  • [8] Development of a proton Computed Tomography detector system
    Naimuddin, Md.
    Coutrakon, G.
    Blazey, G.
    Boi, S.
    Dyshkant, A.
    Erdelyi, B.
    Hedin, D.
    Johnson, E.
    Krider, J.
    Rukalin, V.
    Uzunyan, S. A.
    Zutshi, V.
    Fordt, R.
    Sellberg, G.
    Rauch, J. E.
    Roman, M.
    Rubinov, P.
    Wilson, P.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [9] Meeting the detector challenges for pre-clinical proton and ion computed tomography
    Johnson, Robert P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11)
  • [10] Exploration of differentiability in a proton computed tomography simulation framework
    Aehle, Max
    Alme, Johan
    Barnafoldi, Gergely Gabor
    Bluehdorn, Johannes
    Bodova, Tea
    Borshchov, Vyacheslav
    van den Brink, Anthony
    Eikeland, Viljar
    Feofilov, Gregory
    Garth, Christoph
    Gauger, Nicolas R.
    Grottvik, Ola
    Helstrup, Havard
    Igolkin, Sergey
    Keidel, Ralf
    Kobdaj, Chinorat
    Kortus, Tobias
    Kusch, Lisa
    Leonhardt, Viktor
    Mehendale, Shruti
    Mulawade, Raju Ningappa
    Odland, Odd Harald
    O'Neill, George
    Papp, Gabor
    Peitzmann, Thomas
    Pettersen, Helge Egil Seime
    Piersimoni, Pierluigi
    Pochampalli, Rohit
    Protsenko, Maksym
    Rauch, Max
    Rehman, Attiq Ur
    Richter, Matthias
    Roehrich, Dieter
    Sagebaum, Max
    Santana, Joshua
    Schilling, Alexander
    Seco, Joao
    Songmoolnak, Arnon
    Sudar, Akos
    Tambave, Ganesh
    Tymchuk, Ihor
    Ullaland, Kjetil
    Varga-Kofarago, Monika
    Volz, Lennart
    Wagner, Boris
    Wendzel, Steffen
    Wiebel, Alexander
    Xiao, Renzheng
    Yang, Shiming
    Zillien, Sebastian
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (24)