Experimental study on two-phase condensation heat transfer and pressure drop of R-134a flowing in a dimpled tube

被引:83
作者
Aroonrat, Kanit [1 ]
Wongwises, Somchai [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Fac Engn, Dept Mech Engn, Fluid Mech Thermal Engn & Multiphase Flow Res Lab, Bangkok, Thailand
关键词
Condensation; Heat transfer; Pressure drop; Dimpled tube; HORIZONTAL SMOOTH; TRANSFER COEFFICIENTS; NUMERICAL CORRELATION; TRANSFER ENHANCEMENT; TURBULENT PIPE; EVAPORATION; HFC-134A; MODEL; R134A;
D O I
10.1016/j.ijheatmasstransfer.2016.08.046
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates the heat transfer and pressure drop of R-134a during condensation inside a dimpled tube. The test section is a horizontal counter-flow double-tube heat exchanger with refrigerant flowing in the inner tube and cold water flowing in the annulus. The inner tubes consist of one smooth tube and one dimpled tube, which are made from copper. The length and inner diameter of the test tube are 1500 mm and 8.1 mm, respectively. The test runs are performed at saturation temperatures of 40, 45, and 50 degrees C, heat fluxes of 10, 15, and 20 kW/m(2), and mass fluxes of 300, 400, and 500 kg/m(2)s. The effects of heat flux, mass flux, and saturation temperature on the heat transfer coefficient and frictional pressure drop are examined. Comparisons between smooth and dimpled tubes on the heat transfer and frictional pressure drop are also discussed. It is observed that the heat transfer coefficient and frictional pressure drop obtained from a dimpled tube are higher than that of the smooth tube. In addition, as the equivalent Reynolds number increases, the dimpled tube enhances the Nusselt number around 1.3-1.4 times in comparison to the smooth tube. Whereas, when the equivalent Reynolds number decreases, the twophase friction factor rises around 2.8-4.1 times as compared to the smooth tube. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:437 / 448
页数:12
相关论文
共 34 条
[11]   The influence of artificial roughness shape on heat transfer enhancement: Corrugated tubes, dimpled tubes and wire coils [J].
Garcia, A. ;
Solano, J. P. ;
Vicente, P. G. ;
Viedma, A. .
APPLIED THERMAL ENGINEERING, 2012, 35 :196-201
[12]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[13]   Condensation and evaporation heat transfer characteristics in horizontal smooth, herringbone and enhanced surface EHT tubes [J].
Guo, Si-pu ;
Wu, Zan ;
Li, Wei ;
Kukulka, David ;
Sunden, Bengt ;
Zhou, Xiao-peng ;
Wei, Jin-jia ;
Simon, Terrence .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 85 :281-291
[14]   Condensation of R-134a inside a helically coiled tube-in-shell heat exchanger [J].
Gupta, Abhinav ;
Kumar, Ravi ;
Gupta, Akhilesh .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 54 :279-289
[15]   SIMPLE AND EXPLICIT FORMULAS FOR THE FRICTION FACTOR IN TURBULENT PIPE-FLOW [J].
HAALAND, SE .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (01) :89-90
[16]   Flow condensation heat transfer coefficients of pure refrigerants [J].
Jung, D ;
Song, KH ;
Cho, Y ;
Kim, SJ .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01) :4-11
[17]   Comparison of tubeside condensation and evaporation characteristics of smooth and enhanced heat transfer 1EHT tubes [J].
Kukulka, David J. ;
Smith, Rick ;
Li, Wei .
APPLIED THERMAL ENGINEERING, 2015, 89 :1079-1086
[18]   Development and evaluation of enhanced heat transfer tubes [J].
Kukulka, David J. ;
Smith, Rick ;
Fuller, Kevin G. .
APPLIED THERMAL ENGINEERING, 2011, 31 (13) :2141-2145
[19]   Condensation heat transfer and flow characteristics of R-134a flowing through corrugated tubes [J].
Laohalertdecha, Suriyan ;
Wongwises, Somchai .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (11-12) :2673-2682
[20]   The effects of corrugation pitch on the condensation heat transfer coefficient and pressure drop of R-134a inside horizontal corrugated tube [J].
Laohalertdecha, Suriyan ;
Wongwises, Somchai .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (13-14) :2924-2931