New multilayer coating using quaternary ammonium chitosan and κ-carrageenan in capillary electrophoresis: Application in fast analysis of betaine and methionine

被引:25
作者
Vitali, Luciano [1 ]
Della Betta, Fabiana [1 ]
Costa, Ana Carolina O. [1 ]
Simas Vaz, Fernando Antonio [2 ]
Leal Oliveira, Marcone Augusto [2 ]
Vistuba, Jacqueline Pereira [3 ]
Favere, Valfredo T. [3 ]
Micke, Gustavo A. [3 ]
机构
[1] Univ Fed Santa Catarina, Dept Sci & Food Technol, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Juiz de Fora, Dept Chem, Juiz De Fora, MG, Brazil
[3] Univ Fed Santa Catarina, Dept Chem, BR-88040900 Florianopolis, SC, Brazil
关键词
Capillary electrophoresis; Multilayer coating; Betaine; Methionine; Pharmaceutical formulations; Fast method; BILAYER-COATED CAPILLARIES; TANDEM MASS-SPECTROMETRY; AMINO-ACIDS; ZONE-ELECTROPHORESIS; CHROMATOGRAPHY; SEPARATIONS; PROTEINS; PLASMA; QUANTITATION; INJECTION;
D O I
10.1016/j.talanta.2014.01.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study was to develop a new multilayer coating with crosslinked quaternary ammonium chitosan (hydroxypropyltrimethyl ammonium chloride chitosan; HACC) and ic-carrageenan for use in capillary electrophoresis. A new semi-permanent multilayer coating was formed using the procedure developed and the method does not require the presence of polymers in the background electrolyte (BGE). The new capillary multilayer coating showed a cathodic electroosmotic flow (EOF) of around 30 x 10(-9) m(2) V-1 s(-1) which is pH-independent in the range of pH 2 to 10. The enhanced EOF at low pH obtained contributed significantly to the development of a fast method of separation. The multilayer coating was then applied in the development of a fast separation method to determine betaine and methionine in pharmaceutical formulations by capillary zone electrophoresis (CZE). The BGE used to determine the betaine and methionine concentrations was composed of 10 mmol L-1 tris(hydroxymethyl) aminomethane, 40 mmol L-1 phosphoric acid and 10% (v/v) ethanol, at pH 2.1. A fused-silica capillary of 32 cm (50 gm ID x 375 pm OD) was used in the experiments and samples and standards were analyzed employing the short-end injection procedure (8.5 cm effective length). The instrumental analysis time of the optimized method was 1.53 min (approx. 39 runs per hour). The validation of the proposed method for the determination of betaine and methionine showed good linearity (R-2 > 0.999), adequate limit of detection (LOD <8 mg L-1) for the concentration in the samples and inter-day precision values lower than 3.5% (peak area and time migration). The results for the quantification of the amino acids in the samples determined by the CZE-UV method developed were statistically equal to those obtained with the comparative LC-MS/MS method according to the paired t-test with a confidence level of 95%. (c) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 52 条
  • [1] Capillary electrophoresis for the analysis of small-molecule pharmaceuticals
    Altria, Kevin
    Marsh, Alex
    Sanger-van de Griend, Carl
    [J]. ELECTROPHORESIS, 2006, 27 (12) : 2263 - 2282
  • [2] [Anonymous], 2005, INT C HARM TECHN REQ
  • [3] Betaine, ethanol, and the liver: A review
    Barak, AJ
    Beckenhauer, HC
    Tuma, DJ
    [J]. ALCOHOL, 1996, 13 (04) : 395 - 398
  • [4] Bendahl L, 2001, ELECTROPHORESIS, V22, P2565, DOI 10.1002/1522-2683(200107)22:12<2565::AID-ELPS2565>3.0.CO
  • [5] 2-I
  • [6] Carrageenans: Biological properties, chemical modifications and structural analysis - A review
    Campo, Vanessa Leiria
    Kawano, Daniel Fabio
    da Silva, Dilson Braz, Jr.
    Carvalho, Ivone
    [J]. CARBOHYDRATE POLYMERS, 2009, 77 (02) : 167 - 180
  • [7] Analysis of recombinant human growth hormone by capillary electrophoresis with bilayer-coated capillaries using UV and MS detection
    Catai, Jonatan R.
    Torano, Javier Sastre
    Jongen, Peter M. J. M.
    de Jong, Gerhardus J.
    Somsen, Govert W.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 160 - 166
  • [8] Noncovalently bilayer-coated capillaries for efficient and reproducible analysis of proteins by capillary electrophoresis
    Catai, JR
    Tervahauta, HA
    de Jong, GJ
    Somsen, GW
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1083 (1-2) : 185 - 192
  • [9] Rapid analysis of essential and branched-chain amino acids in nutraceutical products by micellar electrokinetic capillary chromatography
    Cavazza, A
    Corradini, C
    Lauria, A
    Nicoletti, I
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (08) : 3324 - 3329
  • [10] Guidelines for calibration in analytical chemistry - Part 1. Fundamentals and single component calibration (IUPAC recommendations 1998)
    Danzer, K
    Currie, LA
    [J]. PURE AND APPLIED CHEMISTRY, 1998, 70 (04) : 993 - 1014