High-order multibland encoding in the heart

被引:13
作者
Cunningham, CH
Wright, GA
Wood, ML
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] ASL W, GE Med Syst, Menlo Pk, CA USA
[4] GE Med Syst, Waukesha, WI USA
[5] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
关键词
selective excitation; Hadamard encoding; RF pulse; cardiac imaging; coronary artery;
D O I
10.1002/mrm.10277
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spatial encoding with multiband selective excitation (e.g., Hadamard encoding) has been restricted to a small number of slices because the RF pulse becomes unacceptably long when more than about eight slices are encoded. In this work, techniques to shorten multiband RF pulses, and thus allow larger numbers of slices, are investigated. A method for applying the techniques while retaining the capability of adaptive slice thickness is outlined. A tradeoff between slice thickness and pulse duration is shown. Simulations and experiments with the shortened pulses confirmed that motion-induced excitation profile blurring and phase accrual were reduced. The connection between gradient hardware limitations, slice thickness, and flow sensitivity is shown. Excitation profiles for encoding 32 contiguous slices of 1-mm thickness were measured experimentally, and the artifact resulting from errors in timing of RF pulse relative to gradient was investigated. A multiband technique for imaging 32 contiguous 2-mm slices, with adaptive slice thickness, was developed and demonstrated for coronary artery imaging in healthy subjects. With the ability to image high numbers of contiguous slices, using relatively short (1-2 ms) RF pulses, multiband encoding has been advanced further toward practical application. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:689 / 698
页数:10
相关论文
共 29 条
  • [1] Bracewell R. N., 1986, FOURIER TRANSFORM IT, V31999
  • [2] EFFECTS OF RF AMPLIFIER DISTORTION ON SELECTIVE EXCITATION AND THEIR CORRECTION BY PREWARPING
    CHAN, F
    PAULY, J
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) : 224 - 238
  • [3] VARIABLE-RATE SELECTIVE EXCITATION
    CONOLLY, S
    NISHIMURA, D
    MACOVSKI, A
    GLOVER, G
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03): : 440 - 458
  • [4] Cunningham CH, 2001, MAGNET RESON MED, V45, P118, DOI 10.1002/1522-2594(200101)45:1<118::AID-MRM1016>3.0.CO
  • [5] 2-S
  • [6] Cunningham CH, 1999, MAGNET RESON MED, V42, P577, DOI 10.1002/(SICI)1522-2594(199909)42:3<577::AID-MRM21>3.0.CO
  • [7] 2-E
  • [8] CUNNINGHAM CH, 2002, P 10 ANN M ISMRM HON, P298
  • [9] CUNNINGHAM CH, 2001, P 9 ANN M ISMRM GLAS, P1861
  • [10] METHODS FOR RECONSTRUCTING PHASE-SENSITIVE SLICE PROFILES IN MAGNETIC-RESONANCE-IMAGING
    DEVOULON, P
    EMSLEY, L
    WEBER, P
    MEULI, R
    DECORPS, M
    BODENHAUSEN, G
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) : 178 - 183