共 77 条
Automated and semi-automated extraction methods for GC-MS determination of pesticides in environmental samples
被引:37
作者:
Dominguez, Irene
[1
]
Romero Gonzalez, Roberto
[1
]
Arrebola Liebanas, F. Javier
[1
]
Martinez Vidal, Jose L.
[1
]
Garrido Frenich, Antonia
[1
]
机构:
[1] Univ Almeria, Ctr Assessment & Monitoring Global Change CAESCG, Dept Chem & Phys, Analyt Chem Contaminants Res Grp, Agrifood Campus Int Excellence,ceiA3, E-04120 Almeria, Spain
关键词:
Pesticides;
Automated extraction;
Semi-automated extraction;
GC-MS;
Environmental samples;
SOLID-PHASE MICROEXTRACTION;
BAR SORPTIVE EXTRACTION;
CHROMATOGRAPHY-MASS-SPECTROMETRY;
PRIORITY SEMIVOLATILE COMPOUNDS;
PERSISTENT ORGANIC POLLUTANTS;
GAS-CHROMATOGRAPHY;
WATER SAMPLES;
ORGANOCHLORINE PESTICIDES;
THERMAL-DESORPTION;
RESIDUE ANALYSIS;
D O I:
10.1016/j.teac.2016.09.001
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
A highly efficient extraction of analytes is crucial for the determination of pesticides in environmental samples at ultra-trace levels. In order to reduce sample handling and improve analysis productivity, extraction methods should be automated. However, fully automation is not always possible. In the present review, the use of automated and semi-automated extraction procedures coupled to gas chromatography mass spectrometry (GG-MS) for the determination of pesticides in environmental samples are revised, highlighting their advantages as well as their disadvantages. Among automated or semi-automated extraction techniques, solid phase microextraction (SPME) is the most widely used methodology for the determination of pesticides in environmental samples. In addition, analytical methods based on automated solid phase extraction (SPE) or extraction procedures requiring minimal sample handling, such as stir bar sorptive extraction (SBSE) and liquid phase microextraction (LPME) procedures, have also been coupled to GC-MS and applied for the determination of pesticides in environmental samples. Therefore, methodologies based on these extraction techniques are also considered in this paper. The combination of these procedures with GC-MS has allowed the determination of pesticides with acceptable relative recoveries (>70% in most cases) and low limits of detection (LOD), in the range of few mu g L (1)-ng L (1). Nevertheless, increased efforts aimed at achieving the highest possible recoveries and lowest LOD values, as well as the complete automation of the analytical techniques, are still required. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文