A flow-through potentiometric sensor for an integrated microdialysis system

被引:12
|
作者
Pijanowska, DG
Sprenkels, A
van der Linden, H
Olthuis, W
Bergveld, P
van den Berg, A
机构
[1] Univ Twente, MESA, Res Inst, NL-7500 AE Enschede, Netherlands
[2] Polish Acad Sci, Inst Biocybernet & Biomed Engn, PL-02109 Warsaw, Poland
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 103卷 / 1-2期
关键词
potentiometric sensor; flow-through system; potassium sensor; microdialysis; lab-on-a-chip; mu TAS;
D O I
10.1016/j.snb.2004.04.108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the performance of a flow-through potentiometric sensor based on a semi-permeable dialysis tubing implemented in silicon, is presented. The sensor is designed as part of a lab-on-a-chip system and has been successfully incorporated into an integrated microdialysis system. Results of a potassium sensor, operating stand-alone, and as part of the integrated system are presented. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 50 条
  • [41] A novel glucose sensor system with Au nanoparticles based on microdialysis and coenzymes for continuous glucose monitoring
    Pan, M
    Guo, XS
    Cai, Q
    Li, G
    Chen, YQ
    SENSORS AND ACTUATORS A-PHYSICAL, 2003, 108 (1-3) : 258 - 262
  • [42] Recovery of shale oil condensate from different oil shales using a flow-through apparatus
    Amer, Mohammad W.
    Fei, Yi
    Marshall, Marc
    Jackson, W. Roy
    Gorbaty, Martin
    Chaffee, Alan L.
    FUEL PROCESSING TECHNOLOGY, 2015, 133 : 167 - 172
  • [43] High temporal resolution monitoring of fermentations using an on-line amperometric flow-through microdetector
    Zor, Kinga
    Gaspar, Szilveszter
    Hashimoto, Masatoshi
    Suzuki, Hiroaki
    Csoregi, Elisabeth
    ELECTROANALYSIS, 2007, 19 (01) : 43 - 48
  • [44] Flow-Through Microvial Facilitating Interface of Capillary Isoelectric Focusing and Electrospray Ionization Mass Spectrometry
    Zhong, Xuefei
    Maxwell, E. Jane
    Ratnayake, Chitra
    Mack, Scott
    Chen, David D. Y.
    ANALYTICAL CHEMISTRY, 2011, 83 (22) : 8748 - 8755
  • [45] Replication quality of flow-through microfilters in microfluidic lab-on-a-chip for blood typing by Microinjection molding
    Lee, Bong-Kee
    Hwang, Chul Jin
    Kim, Dong Sung
    Kwon, Tai Hun
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (02): : 0210101 - 0210108
  • [46] Continuous flow-through steady state system for in vitro characterization of CYP11B2 inhibitors-Impact on enzyme kinetics of steroidogenesis
    Froebel, Dennis
    Hahner, Stefanie
    Heinze, Britta
    Dieterich, Peter
    Constantinescu, Georgiana
    Mir-Bashiri, Sanas
    Williams, Tracy Ann
    Peitzsch, Mirko
    Eisenhofer, Graeme
    Schirbel, Andreas
    Bechmann, Nicole
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2025, 250
  • [47] Measuring the metabolism of marine organisms in continuous flow-through systems: A mathematical justification and practical implementation of a method
    Cherbadgy, I. I.
    Zvalinsky, V. I.
    RUSSIAN JOURNAL OF MARINE BIOLOGY, 2013, 39 (04) : 295 - 300
  • [48] New design of a flow-through permeation cell for studying in vitro permeation studies across biological membranes
    Tanojo, H
    Roemele, PEH
    vanVeen, GH
    Stieltjes, H
    Junginger, HE
    Bodde, HE
    JOURNAL OF CONTROLLED RELEASE, 1997, 45 (01) : 41 - 47
  • [49] Measuring the metabolism of marine organisms in continuous flow-through systems: A mathematical justification and practical implementation of a method
    I. I. Cherbadgy
    V. I. Zvalinsky
    Russian Journal of Marine Biology, 2013, 39 : 295 - 300
  • [50] A stopped-flow microdialysis sampling-flow injection system for automated multivessel high resolution drug dissolution testing
    Fang, Q
    Liu, SS
    Wu, JF
    Sun, YQ
    Fang, ZL
    TALANTA, 1999, 49 (02) : 403 - 414