A flow-through potentiometric sensor for an integrated microdialysis system

被引:12
|
作者
Pijanowska, DG
Sprenkels, A
van der Linden, H
Olthuis, W
Bergveld, P
van den Berg, A
机构
[1] Univ Twente, MESA, Res Inst, NL-7500 AE Enschede, Netherlands
[2] Polish Acad Sci, Inst Biocybernet & Biomed Engn, PL-02109 Warsaw, Poland
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 103卷 / 1-2期
关键词
potentiometric sensor; flow-through system; potassium sensor; microdialysis; lab-on-a-chip; mu TAS;
D O I
10.1016/j.snb.2004.04.108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the performance of a flow-through potentiometric sensor based on a semi-permeable dialysis tubing implemented in silicon, is presented. The sensor is designed as part of a lab-on-a-chip system and has been successfully incorporated into an integrated microdialysis system. Results of a potassium sensor, operating stand-alone, and as part of the integrated system are presented. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 50 条
  • [31] Water Renewal Simulation in Two Flow-Through Water Bodies in Western Greece
    Fourniotis, Nikolaos Th.
    Leftheriotis, Georgios A.
    WATER, 2023, 15 (15)
  • [32] Immobilized Luminescent Bacteria for the Detection of Mycotoxins under Discrete and Flow-Through Conditions
    Senko, Olga
    Stepanov, Nikolay
    Maslova, Olga
    Akhundov, Rashid
    Ismailov, Anvar
    Efremenko, Elena
    BIOSENSORS-BASEL, 2019, 9 (02):
  • [33] Technical concept of a flow-through microreactor for in-situ RT-PCR
    Felbel, J.
    Reichert, A.
    Kielpinski, M.
    Urban, M.
    Haefner, N.
    Duerst, M.
    Koehler, J. M.
    Weber, J.
    Henkel, T.
    ENGINEERING IN LIFE SCIENCES, 2008, 8 (01): : 68 - 72
  • [34] An integrated electronic meniscus sensor for measurement of evaporative flow
    Gazzola, D.
    Iafelice, B.
    Jung, E.
    Scarselli, E. Franchi
    Guerrieri, R.
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 145 : 194 - 200
  • [35] Chemiluminescence flow sensor for in vivo on-line monitoring of glucose in awake rabbit by microdialysis sampling
    Li, BX
    Zhang, ZJ
    Jin, Y
    ANALYTICA CHIMICA ACTA, 2001, 432 (01) : 95 - 100
  • [36] An integrated electronic meniscus sensor for measurement of evaporative flow
    Gazzola, D.
    Iafelice, B.
    Jung, E.
    Franchi, E.
    Guerrieri, R.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [37] Inactivation of Escherichia coli K-12 in Liquid Egg White by a Flow-Through Pulsed UV Light Treatment System
    Ouyang, Beining
    Demirci, Ali
    Patterson, Paul H.
    JOURNAL OF FOOD PROTECTION, 2020, 83 (03) : 418 - 425
  • [38] Comparative study of the culturable microbiota present in two different rearing systems, flow-through system (FTS) and recirculation system (RAS), in a great scallop hatchery
    Dieguez, Ana L.
    Balboa, Sabela
    Magnesen, Thorolf
    Jacobsen, Anita
    Lema, Alberto
    Romalde, Jesus L.
    AQUACULTURE RESEARCH, 2020, 51 (02) : 542 - 556
  • [39] Dynamic flow-through approach to evaluate readily bioaccessible antioxidants in solid food samples
    Maia, Miguel A.
    Soares, Tania R. P.
    Mota, Ana I. P.
    Rosende, Maria
    Magalhaes, Luis M.
    Miro, Manuel
    Segundo, Marcela A.
    TALANTA, 2017, 166 : 162 - 168
  • [40] Lateral porous silicon interferometric transducer for on-chip flow-through sensing applications
    He, Yingning
    Vasconcellos, Douglas Silva de
    Bourrier, David
    Hajdu, Kata
    Durand, Jean-Olivier
    Cunin, Frederique
    Bardinal, Veronique
    Leichle, Thierry
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 332