A flow-through potentiometric sensor for an integrated microdialysis system

被引:12
|
作者
Pijanowska, DG
Sprenkels, A
van der Linden, H
Olthuis, W
Bergveld, P
van den Berg, A
机构
[1] Univ Twente, MESA, Res Inst, NL-7500 AE Enschede, Netherlands
[2] Polish Acad Sci, Inst Biocybernet & Biomed Engn, PL-02109 Warsaw, Poland
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 103卷 / 1-2期
关键词
potentiometric sensor; flow-through system; potassium sensor; microdialysis; lab-on-a-chip; mu TAS;
D O I
10.1016/j.snb.2004.04.108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the performance of a flow-through potentiometric sensor based on a semi-permeable dialysis tubing implemented in silicon, is presented. The sensor is designed as part of a lab-on-a-chip system and has been successfully incorporated into an integrated microdialysis system. Results of a potassium sensor, operating stand-alone, and as part of the integrated system are presented. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 50 条
  • [21] Electrochemical cell lysis on a miniaturized flow-through device
    Jha, Sandeep Kumar
    Ra, Gyu-Sik
    Joo, Gi-Sung
    Kim, Yong-Sang
    CURRENT APPLIED PHYSICS, 2009, 9 (04) : E301 - E303
  • [22] Evaluation and Optimization of Factors Affecting the Performance of a Flow-through System Based on Immobilized Acetylcholineesterase as a Biosensor
    Ebrahimi, Bahman
    Shojaosadati, Seyed Abbas
    Mousavi, Seyyed Mohammad
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2010, 15 (03) : 383 - 391
  • [23] Evaluation and optimization of factors affecting the performance of a flow-through system based on immobilized acetylcholineesterase as a biosensor
    Bahman Ebrahimi
    Seyed Abbas Shojaosadati
    Seyyed Mohammad Mousavi
    Biotechnology and Bioprocess Engineering, 2010, 15 : 383 - 391
  • [24] A wearable potentiometric sensor with integrated salt bridge for sweat chloride measurement
    Choi, Dong-Hoon
    Li, Yi
    Cutting, Garry R.
    Searson, Peter C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 250 : 673 - 678
  • [25] Applying heat and mass balance theory to determine the flow rate for the measurement of benthic material flux in a flow-through system
    Yamamoto, T
    Ikeda, H
    Hara, T
    Takeoka, H
    HYDROBIOLOGIA, 2000, 435 (1-3) : 135 - 142
  • [26] Applying heat and mass balance theory to determine the flow rate for the measurement of benthic material flux in a flow-through system
    Tamiji Yamamoto
    Hiroyuki Ikeda
    Tamotsu Hara
    Hidetaka Takeoka
    Hydrobiologia, 2000, 435 : 135 - 142
  • [27] Characteristics of bioconcentration and depuration of endocrine disruption chemicals in the flounder,Paralichthys olivaceus, under flow-through system
    Lee J.-H.
    Cho C.
    Kim H.-Y.
    Cho H.-S.
    Toxicology and Environmental Health Sciences, 2010, 2 (4) : 221 - 230
  • [28] Functional morphology and performance of New Zealand geoduck clam (Panopea zelandica) larvae reared in a flow-through system
    Le, Dung V.
    Alfaro, Andrea C.
    Ragg, Norman L. C.
    Hilton, Zoe
    Watts, Ellie
    King, Nick
    AQUACULTURE, 2017, 468 : 32 - 44
  • [29] Remediating sulfadimethoxine-contaminated aquaculture wastewater using ZVI-activated persulfate in a flow-through system
    Chokejaroenrat, Chanat
    Sakulthaew, Chainarong
    Angkaew, Athaphon
    Satapanajaru, Tunlawit
    Poapolathep, Amnart
    Chirasatienpon, Tharisara
    AQUACULTURAL ENGINEERING, 2019, 84 : 99 - 105
  • [30] Survival and development of five species of cyclopoid copepods in relation to food supply: experiments with algal food in a flow-through system
    Hopp, U
    Maier, G
    FRESHWATER BIOLOGY, 2005, 50 (09) : 1454 - 1463