A flow-through potentiometric sensor for an integrated microdialysis system

被引:12
|
作者
Pijanowska, DG
Sprenkels, A
van der Linden, H
Olthuis, W
Bergveld, P
van den Berg, A
机构
[1] Univ Twente, MESA, Res Inst, NL-7500 AE Enschede, Netherlands
[2] Polish Acad Sci, Inst Biocybernet & Biomed Engn, PL-02109 Warsaw, Poland
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 103卷 / 1-2期
关键词
potentiometric sensor; flow-through system; potassium sensor; microdialysis; lab-on-a-chip; mu TAS;
D O I
10.1016/j.snb.2004.04.108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the performance of a flow-through potentiometric sensor based on a semi-permeable dialysis tubing implemented in silicon, is presented. The sensor is designed as part of a lab-on-a-chip system and has been successfully incorporated into an integrated microdialysis system. Results of a potassium sensor, operating stand-alone, and as part of the integrated system are presented. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 50 条
  • [1] Novel design of a planar flow-through potentiometric sensor
    Guagneli, Luca
    Mousavi, Zekra
    Sokalski, Tomasz
    Leito, Ivo
    Bobacka, Johan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 923
  • [2] On-chip microdialysis system with flow-through sensing components
    Hsieh, Yi-Cheng
    Zahn, Jeffrey D.
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) : 2422 - 2428
  • [3] A flow-through amperometric sensor for micro-analytical systems
    Pijanowska, DG
    Sprenkels, AJ
    Olthuis, W
    Bergveld, P
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3): : 98 - 102
  • [4] Amperometric biosensor-based flow-through microdetector for microdialysis applications
    Gáspár, S
    Wang, XW
    Suzuki, H
    Csöregi, E
    ANALYTICA CHIMICA ACTA, 2004, 525 (01) : 75 - 82
  • [5] A FLOW-THROUGH SYSTEM FOR THE DETERMINATION OF SALICYLATE IN BLOOD
    BERTOCCHI, P
    DOTTAVIO, D
    EVANGELISTI, ME
    MASCINI, M
    PALLESCHI, G
    CLINICA CHIMICA ACTA, 1992, 207 (03) : 205 - 213
  • [6] A simple flow-through system for toxicity testing with daphnids
    Tisler, T
    Zagorc-Koncan, J
    WATER AIR AND SOIL POLLUTION, 1999, 111 (1-4) : 327 - 336
  • [7] A Simple Flow-through System for Toxicity Testing with Daphnids
    Tatjana Tišler
    Jana Zagorc-končan
    Water, Air, and Soil Pollution, 1999, 111 : 327 - 336
  • [8] Fiber-optic flow-through sensor for online monitoring of glucose
    Pasic, Alen
    Koehler, Hans
    Schaupp, Lukas
    Pieber, Thomas R.
    Klimant, Ingo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (05) : 1293 - 1302
  • [9] Fiber-optic flow-through sensor for online monitoring of glucose
    Alen Pasic
    Hans Koehler
    Lukas Schaupp
    Thomas R. Pieber
    Ingo Klimant
    Analytical and Bioanalytical Chemistry, 2006, 386 : 1293 - 1302
  • [10] Sequential Fractionation of Spruce Bark in a Continuous Flow-through System
    Ramazanova, Lala
    Reimund, Lena
    Lebedeva, Daria
    Muangmeesri, Suthawan
    Jaworski, Aleksander
    Samec, Joseph S. M.
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2024, 12 (36): : 13409 - 13414