A graphical approach to the unipolar point-to-plane corona

被引:5
|
作者
Amoruso, V [1 ]
Lattarulo, F [1 ]
机构
[1] POLITECN BARI,DIPARTIMENTO ELETTROTECN & ELETTRON,I-70125 BARI,ITALY
关键词
corona; point-to-plane geometry; ion flow; unipolar corona; Warburg law; Deutsch law;
D O I
10.1016/S0304-3886(96)00037-X
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new method based on a simple geometrical construction is proposed to describe the asymptotic ion flow arrangement for the rod-plane assembly. This procedure leads to a generalised formula for the planar current which represents a valid option to the empirical Warburg law. Some validation criteria involving available experimental data are also presented. Finally, a Deutsch hypothesis-based formulation is discussed for calculating the corona ionized electric field.
引用
收藏
页码:41 / 51
页数:11
相关论文
共 45 条
  • [1] A semi-analytical stationary model of a point-to-plane corona discharge
    Yanallah, K.
    Pontiga, F.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2012, 21 (04)
  • [2] Current density distribution measurement of negative point-to-plane corona discharge
    Madani, MR
    Miller, TA
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (04) : 907 - 913
  • [3] A Comparison of SF6 Decomposition Characteristics under Corona with Point-to-plane Electrode Defect and Spark with Floating Potential Defect
    Ding, Weidong
    Li, Guojun
    Ren, Xiang
    Yan, Xianglian
    Li, Feng
    Zhou, Wenwu
    Wang, Feng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) : 3278 - 3289
  • [4] Simulation of corona discharge in point-plane configuration
    Adamiak, K
    Atten, P
    JOURNAL OF ELECTROSTATICS, 2004, 61 (02) : 85 - 98
  • [5] Analysis of Frequencies Radiated by the Point-to-Plane Electrode Configuration under DC and AC Voltages
    Bhangaonkar, Avinash S.
    Dudani, Kalpesh K.
    Kulkarni, Shrikrishna V.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2009, 10 (03):
  • [6] Decomposition Characteristics of SF6 under Partial Discharges with Point-to-plane Electrode Defect
    Ding Weidong
    Zhou Wenwu
    Ren Xiang
    Li Guojun
    Fan Chuan
    Duan Wei
    Song Gao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (05) : 1727 - 1736
  • [7] Study of the Effects of Alternating Magnetic Field on Point-plane Corona
    Bhangaonkar, Avinash S.
    Kulkarni, S. V.
    Shevgaonkar, R. K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (06) : 1813 - 1820
  • [8] The Different Stages of PRPD Pattern for Positive Point to Plane Corona Driven by a DC Voltage Containing Ripple
    Dezenzo, Tobias
    Betz, Thomas
    Schwarzbacher, Andreas
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (01) : 30 - 37
  • [9] The Different Stages of PRPD Pattern for Negative Point to Plane Corona Driven by a DC Voltage Containing a Ripple
    Dezenzo, Tobias
    Betz, Thomas
    Schwarzbacher, Andreas
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) : 47 - 53
  • [10] An approach for unipolar corona discharge in N2/O2 gas mixture by considering townsend conditions
    Alisoy, Hafiz Z.
    Yesil, Ali
    Koseoglu, Murat
    Unal, Ibrahim
    JOURNAL OF ELECTROSTATICS, 2011, 69 (04) : 284 - 290