A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Branemark system implants

被引:60
|
作者
Turkyilmaz, I.
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Univ Gothenburg, Inst Surg Sci, Dept Biomat, Gothenburg, Sweden
关键词
dental implant; insertion torque; resonance frequency; correlation; early loading;
D O I
10.1111/j.1365-2842.2006.01631.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine primary stability and insertion torque of Branemark System implants placed in the anterior mandible, and to evaluate a possible correlation between primary stability and insertion torque. Thirty edentulous patients were treated with 60 Branemark System implants using a one-stage technique. The insertion torque values of all implants were recorded with the Osseocare equipment. Immediately after implant placement, each implant was connected to the transducer of an Osstell machine to measure the primary implant stability. The average insertion torque and resonance frequency values were 41.5 +/- 5.8 and 74.1 +/- 3.8 for 30 implants. The correlation between insertion torque and resonance frequency values indicated a statistical significance (P < 0.001). The difference between mean insertion torque values for female and male patients was statistically significant (P < 0.001). No significant difference (P > 0.05) was found between younger and older patients with mean insertion torque values of 43.1 +/- 4.7 and 40.1 +/- 6.5 respectively. The results of this study showed a strong correlation between the primary stability and insertion torque values of Branemark System TiUnite MKIII implants at the time of implant placement.
引用
收藏
页码:754 / 759
页数:6
相关论文
共 50 条
  • [31] Meta-Analysis of Correlations Between Marginal Bone Resorption and High Insertion Torque of Dental Implants
    Li, Haoyan
    Liang, Yongqiang
    Zheng, Qiang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (04) : 767 - 772
  • [32] Correlation of Fractal Dimension Values with Implant Insertion Torque and Resonance Frequency Values at Implant Recipient Sites
    Suer, Berkay Tolga
    Yaman, Zekai
    Buyuksarac, Bora
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (01) : 55 - 62
  • [33] Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study
    Romanec, Cristian Liviu
    Panaite, Tinela
    Zetu, Irina Nicoleta
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)
  • [34] Resonance Frequency Analysis, Insertion Torque, and Bone to Implant Contact of 4 Implant Surfaces: Comparison and Correlation Study in Sheep
    Dagher, Maroun
    Mokbel, Nadim
    Jabbour, Gabriel
    Naaman, Nada
    IMPLANT DENTISTRY, 2014, 23 (06) : 672 - 678
  • [35] Influence of Defect Depth on Resonance Frequency Analysis and Insertion Torque Values for Implants Placed in Fresh Extraction Sockets: A Human Cadaver Study
    Turkyilmaz, Ilser
    Sennerby, Lars
    Yilmaz, Burak
    Bilecenoglu, Burak
    Ozbek, Esma Nida
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (01) : 52 - 58
  • [36] Correlation between ISQ and Insertion Torque values using double acid-etched implants
    Gallardo, Sebastian
    Constanza Ibanez, Maria
    Carlos Ibanez, Juan
    JOURNAL OF OSSEOINTEGRATION, 2016, 8 (03) : 29 - 36
  • [37] Correlation Between Insertion Torque and Survival Rates in Immediately Loaded Implants in the Maxilla: A Retrospective Study
    Rizkallah, Nadia
    Fischer, Scott
    Kraut, Richard A.
    IMPLANT DENTISTRY, 2013, 22 (03) : 250 - 254
  • [38] Does the manual insertion torque of smartpegs affect the outcome of implant stability quotients (ISQ) during resonance frequency analysis (RFA)?
    Kaestel, Ingrid
    de Quincey, Giles
    Neugebauer, Joerg
    Sader, Robert
    Gehrke, Peter
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2019, 5 (01)
  • [39] Does the manual insertion torque of smartpegs affect the outcome of implant stability quotients (ISQ) during resonance frequency analysis (RFA)?
    Ingrid Kästel
    Giles de Quincey
    Jörg Neugebauer
    Robert Sader
    Peter Gehrke
    International Journal of Implant Dentistry, 5
  • [40] Assessment of the Primary Stability of Dental Implants in Artificial Bone Using Resonance Frequency and Percussion Analyses
    Ahmad, Omaid K.
    Kelly, Robert
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 89 - 95