Mammographic screening of TRAM flap breast reconstructions for detection of nonpalpable recurrent cancer

被引:47
|
作者
Helvie, MA
Bailey, JE
Roubidoux, MA
Pass, HA
Chang, AE
Pierce, LJ
Wilkins, EG
机构
[1] Univ Michigan, Dept Radiol, Taubman Ctr 2910N, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Surg, Taubman Ctr 2910N, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Radiat Oncol, Taubman Ctr 2910N, Ann Arbor, MI 48109 USA
关键词
breast neoplasms; postoperative; radiography; breast radiography;
D O I
10.1148/radiol.2241010061
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate findings from routine mammographic screenings in patients with transverse rectus abdominis musculocutaneous (TRAM) flap reconstructions. MATERIALS AND METHODS: During a 25-month study period, 214 consecutive screening mammograms in 113 asymptomatic women (mean age, 51 years) with TRAM flap reconstructions were obtained. Mastectomies were performed for cancer in 106 (94%) of the 113 women and for prophylaxis in seven (6%). Prospectively, a Breast Imaging Reporting and Data System (BI-RADS) assessment category 1-5 was assigned to each mammogram. Surgical, medical, pathologic, and radiographic records were retrospectively reviewed. CIs were determined by the normal approximation to the binomial distribution. RESULTS: Seven (3%) of 214 examinations were BI-RADS category 4 or 5. Six (86%) of seven patients underwent biopsy. Two (33%) of these six biopsies demonstrated invasive ductal carcinoma. Cancer detection rate for mammography was 1.9% (two of 106) (95% Cl: 0.33%, 7.32%) for women with reconstruction for breast cancer during the 2-year period. One (6%) of 16 BI-RADS category 3 examinations later proved to be invasive ductal carcinoma at follow-up. No interval cancer was discovered in 171 cases of BI-RADS category 1 or 2 examinations with 1-year follow-up. No cancers occurred in women who underwent prophylactic mastectomy. A biopsy positive predictive value of 33% (95% Cl: 6%, 76%) was observed. CONCLUSION: Screening mammography of TRAM flap-reconstructed breasts enables detection of nonpalpable cancer before clinical examination. (C) RSNA 2002.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
  • [41] An analysis of 11.3 million screening tests examining the association between recall and cancer detection rates in the English NHS breast cancer screening programme
    Blanks, R. G.
    Given-Wilson, R. M.
    Cohen, S. L.
    Patnick, J.
    Alison, R. J.
    Wallis, M. G.
    EUROPEAN RADIOLOGY, 2019, 29 (07) : 3812 - 3819
  • [42] Diagnostic Accuracy of 18F-FES PET/CT for the Detection of Recurrent and Metastatic Breast Cancer
    Shin, Eonwoo
    Han, Sangwon
    Ryu, Jeongryul
    Eom, Hye-Joung
    Choi, Woo Jung
    Ahn, Jin-Hee
    Son, Byung Ho
    Ahn, Seung Do
    Gong, Gyungyub
    Moon, Dae Hyuk
    CLINICAL NUCLEAR MEDICINE, 2025, 50 (01) : 31 - 37
  • [43] Promoting Breast Cancer Awareness and Screening Practices for Early Detection in Low-Resource Settings
    Wu, Tsu-Yin
    Lee, Joohyun
    EUROPEAN JOURNAL OF BREAST HEALTH, 2019, 15 (01) : 18 - 25
  • [44] Imaging procedures in an intensified high-risk screening program for early detection of hereditary breast cancer: Evaluation by the German Consortium for Breast and Ovarian Cancer
    Fallenberg E.M.
    Schreer I.
    Der Gynäkologe, 2018, 51 (5): : 380 - 390
  • [45] Single reading with computer-aided detection performed by selected radiologists in a breast cancer screening program
    Bargallo, Xavier
    Santamaria, Gorane
    del Amo, Montse
    Arguis, Pedro
    Rios, Jose
    Grau, Jaume
    Burrel, Marta
    Cores, Enrique
    Velasco, Martin
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (11) : 2019 - 2023
  • [46] Early detection breast cancer: role of circulating plasma miRNA-21 expression as a potential screening biomarker
    Diansyah, Muhammad Noor
    Prayogo, Ami Ashariati
    Sedana, Made Putra
    Savitri, Merlyna
    Romadhon, Pradana Zaky
    Amrita, Putu Niken Ayu
    Wijaya, Andi Yasmin
    Hendrata, Winona May
    Bintoro, Ugroseno Yudho
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2021, 51 (02) : 562 - 569
  • [47] Computer-aided detection output on 172 subtle findings on normal mammograms previously obtained in women with breast cancer detected at follow-up screening mammography
    Ikeda, DM
    Birdwell, RL
    O'Shaughnessy, KF
    Sickles, EA
    Brenner, RJ
    RADIOLOGY, 2004, 230 (03) : 811 - 819
  • [48] The effect of changing from one to two views at incident (subsequent) screens in the NHS breast screening programme in England: impact on cancer detection and recall rates
    Blanks, RG
    Bennett, RL
    Patnick, J
    Cush, S
    Davison, C
    Moss, SM
    CLINICAL RADIOLOGY, 2005, 60 (06) : 674 - 680
  • [49] Digital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis
    Sylvia H. Heywang-Köbrunner
    Alexander Jänsch
    Astrid Hacker
    Sina Weinand
    Tobias Vogelmann
    European Radiology, 2022, 32 : 2301 - 2312
  • [50] S3-Leitlinie Mammakarzinom: Aktuelles zur Früherkennung und zum Mammographie-ScreeningS3 guideline breast cancer: update on early detection, and mammography screening
    Ute-Susann Albert
    Ingrid Schreer
    Der Gynäkologe, 2018, 51 (7): : 514 - 520