Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography A Feasibility Animal Study

被引:25
作者
Ren, Liqiang [1 ]
Rajendran, Kishore [1 ]
Fletcher, Joel G. [1 ]
McCollough, Cynthia H. [1 ]
Yu, Lifeng [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 1st St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
contrast materials; photon-counting-detector (PCD); multi-energy CT (MECT); material decomposition; ENERGY CT; AGENTS; MEDIA;
D O I
10.1097/RLI.0000000000000687
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Dual-energy and multienergy computed tomography (DECT/MECT) has the potential to simultaneously visualize two contrast agents in the small bowel: arterial enhancement of iodine in the bowel wall and enteric enhancement of bismuth in the bowel lumen. The purpose of this study was to explore its feasibility in a swine study using a research whole-body photon-counting-detector (PCD) computed tomography (CT) system. Materials and Methods A phantom study was initially performed to evaluate the quantification accuracy of iodine and bismuth separation from a single PCD-CT scan, which also served as the calibration reference for material decomposition of in vivo swine PCD-CT data. In the animal study, a test bolus scan was first performed to determine the time-attenuation curve for the arterial enhancement, based on which the timing of the PCD-CT dual-contrast scan was determined. A 600 mL homogeneous bismuth-saline solution (180 mL Pepto-Bismol + 420 mL normal saline) was orally administered to the pig using esophageal intubation. Approximately 1 hour after bismuth administration, 40 mL iodine contrast (Omnipaque 350, 5 mL/s) was injected intravenously. A PCD-CT scan was performed 13 seconds after the initiation of the contrast injection to simultaneously capture the arterial enhancement of iodine and the enteric enhancement of bismuth. To provide optimal material separation and quantification, all PCD-CT scans in both phantom and animal studies were operated at 140 kV with 4 energy thresholds of 25, 50, 75, and 90 keV. Results Using a generic image-based material decomposition method, the iodine and bismuth samples were successfully delineated and quantified in the phantom images with a root-mean-square-error of 1.32 mg/mL in iodine measurement and 0.64 mg/mL in bismuth measurement. In the pig study, the enhancing bowel wall containing iodine and the small bowel loop containing bismuth were not differentiable in the original PCD-CT images. However, they were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. In addition, quantitative analysis showed that the misclassification between the two contrast materials was less than 1.0 mg/mL. Conclusions Our study demonstrated the feasibility of simultaneous imaging of iodine and bismuth in small bowel of swine using PCD-CT.
引用
收藏
页码:688 / 694
页数:7
相关论文
共 45 条
  • [1] Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners
    Almeida, Isabel P.
    Schyns, Lotte E. J. R.
    Ollers, Michel C.
    van Elmpt, Wouter
    Parodi, Katia
    Landry, Guillaume
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2017, 44 (01) : 171 - 179
  • [2] Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE
    Anderson, N. G.
    Butler, A. P.
    Scott, N. J. A.
    Cook, N. J.
    Butzer, J. S.
    Schleich, N.
    Firsching, M.
    Grasset, R.
    de Ruiter, N.
    Campbell, M.
    Butler, P. H.
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (09) : 2126 - 2134
  • [3] BIERER DW, 1990, REV INFECT DIS, V12, pS3
  • [4] Dead-time correction for spectroscopic photon-counting pixel detectors
    Blaj, Gabriel
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1621 - 1630
  • [5] EPILEPTIC PHENOMENA IN BISMUTH TOXIC ENCEPHALOPATHY
    BUGE, A
    SUPINOVITERBO, V
    RANCUREL, G
    PONTES, C
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1981, 44 (01) : 62 - 67
  • [6] REVERSIBLE ENCEPHALOPATHY POSSIBLY ASSOCIATED WITH BISMUTH SUBGALLATE INGESTION
    BURNS, R
    THOMAS, DW
    BARRON, VJ
    [J]. BRITISH MEDICAL JOURNAL, 1974, 1 (5901) : 220 - 223
  • [7] Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair
    Dangelmaier, Julia
    Bar-Ness, Daniel
    Daerr, Heiner
    Muenzel, Daniela
    Si-Mohamed, Salim
    Ehn, Sebastian
    Fingerle, Alexander A.
    Kimm, Melanie A.
    Kopp, Felix K.
    Boussel, Loic
    Roessl, Ewald
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Proksa, Roland
    Douek, Philippe
    Noel, Peter B.
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (08) : 3318 - 3325
  • [8] Bismuth Toxicity Presenting as Declining Mobility and Falls
    Hogan, David B.
    Harbidge, Cathy
    Duncan, Amy
    [J]. CANADIAN GERIATRICS JOURNAL, 2018, 21 (04): : 307 - 309
  • [9] Predicting Strangulated Small Bowel Obstruction: An Old Problem Revisited
    Jancelewicz, Tim
    Vu, Lan T.
    Shawo, Alexandra E.
    Yeh, Benjamin
    Gasper, Warren J.
    Harris, Hobart W.
    [J]. JOURNAL OF GASTROINTESTINAL SURGERY, 2009, 13 (01) : 93 - 99
  • [10] Assessment of candidate elements for development of spectral photon-counting CT specific contrast agents
    Kim, Johoon
    Bar-Ness, Daniel
    Si-Mohamed, Salim
    Coulon, Philippe
    Blevis, Ira
    Douek, Philippe
    Cormode, David P.
    [J]. SCIENTIFIC REPORTS, 2018, 8