A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources

被引:119
|
作者
Ding, L [1 ]
Sudakov, M [1 ]
Brancia, FL [1 ]
Giles, R [1 ]
Kumashiro, S [1 ]
机构
[1] Shimadzu Res Lab Europe Ltd, Manchester M17 1GP, Lancs, England
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 05期
关键词
quadrupole ion trap; digital ion trap; resonance ejection; resolution; precursor isolation; tandem mass spectrometry; atmospheric pressure ionization;
D O I
10.1002/jms.637
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:471 / 484
页数:14
相关论文
共 50 条
  • [11] Sample pressure effects in a micro ion trap mass spectrometer
    Moxom, J
    Reilly, PTA
    Whitten, WB
    Ramsey, JM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (06) : 721 - 723
  • [12] A secondary ion microprobe ion trap mass spectrometer
    Todd, PJ
    Schaaff, TG
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (09) : 1099 - 1107
  • [13] A secondary ion microprobe ion trap mass spectrometer
    Todd, Peter J.
    Schaaff, T.Gregory
    1600, Elsevier Inc. (13):
  • [14] An Ion Trap-Ion Mobility-Time of Flight Mass Spectrometer with Three Ion Sources for Ion/Ion Reactions
    Zhao, Qin
    Soyk, Matthew W.
    Schieffer, Gregg M.
    Fuhrer, Katrin
    Gonin, Marc M.
    Houk, R. S.
    Badman, Ethan R.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (08) : 1549 - 1561
  • [15] Halo ion trap mass spectrometer
    Austin, Daniel E.
    Wang, Miao
    Tolley, Samuel E.
    Maas, Jeffrey D.
    Hawkins, Aaron R.
    Rockwood, Alan L.
    Tolley, H. Dennis
    Lee, Edgar D.
    Lee, Milton L.
    ANALYTICAL CHEMISTRY, 2007, 79 (07) : 2927 - 2932
  • [16] Performance of an inductively coupled plasma source ion trap mass spectrometer
    Koppenaal, David W., 1600, Royal Soc of Chemistry, Letchworth, United Kingdom (09):
  • [17] Development and Characterization of a Field-Deployable Ion-Trap Mass Spectrometer with an Atmospheric Pressure Interface
    Misharin, Alexander
    Novoselov, Konstantin
    Laiko, Victor
    Doroshenko, Vladimir M.
    ANALYTICAL CHEMISTRY, 2012, 84 (22) : 10105 - 10112
  • [18] High-throughput mass spectrometer using atmospheric pressure ionization and a cylindrical ion trap array
    Misharin, AS
    Laughlin, BC
    Vilkov, A
    Takáts, Z
    Zheng, OY
    Cooks, RG
    ANALYTICAL CHEMISTRY, 2005, 77 (02) : 459 - 470
  • [19] An atmospheric pressure static reactor - ion trap mass spectrometer for studying gas-phase reactions
    Wedian, Fadel
    Atkinson, Dean B.
    CANADIAN JOURNAL OF CHEMISTRY, 2010, 88 (10) : 1017 - 1025
  • [20] Validation of the ozone + tetramethylethylene reaction using an atmospheric pressure flow reactor/ion trap mass spectrometer
    Fadel Z. Wedian
    Dean B. Atkinson
    Journal of Atmospheric Chemistry, 2010, 66 : 65 - 80