Performance of an X-ray imaging detector based on a structured scintillator

被引:34
|
作者
Svenonius, Olof [1 ]
Sahlholm, Anna [1 ]
Wiklund, Per [1 ]
Linnros, Jan [1 ,2 ]
机构
[1] Scint X AB, S-16440 Kista, Sweden
[2] Royal Inst Technol, Dept Microelect & Appl Phys, S-16440 Kista, Sweden
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2009年 / 607卷 / 01期
关键词
X-ray imaging; Scintillator; Cesium iodide; GUIDES; ARRAYS;
D O I
10.1016/j.nima.2009.03.146
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Structured scintillator plates have been fabricated by filling thallium-doped caesium iodide (CsI) into a silicon pore array. Their X-ray imaging properties have been characterized using a standard dental X-ray source and a charge coupled device (CCD) detector. Results indicate that finer structured pore arrays provide superior imaging resolution while their light output is lower. Direct absorption of X-ray quanta in the CCD is a significant contributor of detector noise. This can be avoided by using a thick fibre optic plate or, in certain cases, by using a hot-pixel software algorithm. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 140
页数:3
相关论文
共 50 条
  • [1] An X-ray imaging detector based on pixel structured scintillator
    Kim, Byoung-Jik
    Cho, Gyuseong
    Cha, Bo Kyung
    Kang, Bosun
    RADIATION MEASUREMENTS, 2007, 42 (08) : 1415 - 1418
  • [2] 6 MVp x-ray imaging with a transparent scintillator x-ray detector
    Zeman, HD
    Samant, SS
    Rasmussen, J
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 388 - 394
  • [3] SELECTION OF DIMENSIONS AND GEOMETRY OF A STRUCTURED SCINTILLATOR FOR X-RAY IMAGING
    Sahlholm, Anna
    Svenonius, Olof
    Nasgarde, Carina
    Wiklund, Per
    Linnros, Jan
    PROCEEDINGS OF THE 19TH ESA SYMPOSIUM ON EUROPEAN ROCKET AND BALLOON PROGRAMMES AND RELATED RESEARCH, 2009, 671 : 407 - 409
  • [4] Replacing the detector mask with a structured scintillator in edge-illumination x-ray phase contrast imaging
    Massimi, Lorenzo
    Kallon, Gibril K.
    Buchanan, Ian
    Endrizzi, Marco
    Dobrosz, Piotr
    Brooks, Rob
    Brau, Daniel
    Bullard, Ed
    Olivo, Alessandro
    JOURNAL OF APPLIED PHYSICS, 2022, 131 (20)
  • [5] An X-ray imaging pixel detector based on scintillator filled pores in a silicon matrix
    Kleimann, P
    Linnros, J
    Fröjdh, C
    Petersson, CS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (01): : 15 - 19
  • [6] High-resolution x-ray imaging using a structured scintillator
    Hormozan, Yashar
    Sychugov, Ilya
    Linnros, Jan
    MEDICAL PHYSICS, 2016, 43 (02) : 696 - 701
  • [7] Portal imaging with a CsI(Tl) transparent scintillator x-ray detector
    Zeman, HD
    Samant, SS
    Lovhoiden, G
    Weinberg, B
    Sawant, A
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 175 - 186
  • [8] Towards High-Resolution X-Ray Imaging Using a Structured Scintillator
    Hormozan, Yashar
    Yun, Sang-Ho
    Svenonius, Olof
    Linnros, Jan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) : 19 - 23
  • [9] Modeling of the performance of scintillator based X-ray detectors
    Rocha, JG
    Correia, JH
    Lanceros-Mendez, S
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 1257 - 1260
  • [10] The performance of X-ray scanner using ceramic scintillator base detector module
    Cho, Gyuseong
    Kang, Dong-Wan
    Kim, Kwang Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1321 - 1326