Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images

被引:48
作者
Vasconcelos, Taruska Ventorini [1 ]
Bechara, Boulos B. [2 ]
McMahan, Clyde Alex [3 ]
Freitas, Deborah Queiroz [1 ]
Noujeim, Marcel [2 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Div Oral Radiol, Dept Oral Diag, Sao Paulo, Brazil
[2] Univ Texas Hlth Sci Ctr San Antonio, Dept Comprehens Dent, Div Oral & Maxillofacial Radiol, San Antonio, TX 78229 USA
[3] Univ Texas Hlth Sci Ctr San Antonio, Dept Pathol, San Antonio, TX 78229 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2017年 / 123卷 / 02期
关键词
IN-VITRO ASSESSMENT; REDUCTION; TITANIUM; CT; ACADEMY;
D O I
10.1016/j.oooo.2016.10.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To evaluate zirconium implant artifact production in cone beam computed tomography images obtained with different protocols. Study Design. One zirconium implant was inserted in an edentulous mandible. Twenty scans were acquired with a ProMax 3D unit (Planmeca Oy, Helsinki, Finland), with acquisition settings ranging from 70 to 90 peak kilovoltage (kVp) and voxel sizes of 0.32 and 0.16 mm. A metal artifact reduction (MAR) tool was activated in half of the scans. An axial slice through the middle region of the implant was selected for each dataset. Gray values (mean +/- standard deviation) were measured in two regions of interest, one close to and the other distant from the implant (control area). The contrast-to-noise ratio was also calculated. Results. Standard deviation decreased with greater kVp and when the MAR tool was used. The contrast-to-noise ratio was significantly higher when the MAR tool was turned off, except for low resolution with kVp values above 80. Selection of the MAR tool and greater kVp resulted in an overall reduction of artifacts in images acquired with low resolution. Conclusions. Although zirconium implants do produce image artifacts in cone-bean computed tomography scans, the setting that best controlled artifact generation by zirconium implants was 90 kVp at low resolution and with the MAR tool turned on.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 28 条
[1]  
Angelopoulos Christos, 2011, Dent Clin North Am, V55, P141, DOI 10.1016/j.cden.2010.08.001
[2]   Effective doses in panoramic images from conventional and CBCT equipment [J].
Batista, W. O. G. ;
Navarro, M. V. T. ;
Maia, A. F. .
RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) :67-75
[3]   Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth [J].
Bechara, B. ;
McMahan, C. Alex ;
Moore, W. S. ;
Noujeim, M. ;
Teixeira, F. B. ;
Geha, H. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
[4]   Evaluation of a cone beam CT artefact reduction algorithm [J].
Bechara, B. ;
McMahan, C. A. ;
Geha, H. ;
Noujeim, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (05) :422-428
[5]   Metal artefact reduction with cone beam CT: an in vitro study [J].
Bechara, B. B. ;
Moore, W. S. ;
McMahan, C. A. ;
Noujeim, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) :248-253
[6]   Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines [J].
Bechara, Boulos ;
McMahan, Clyde A. ;
Moore, William S. ;
Noujeim, Marcel ;
Geha, Hassem ;
Teixeira, Fabricio B. .
JOURNAL OF ORAL SCIENCE, 2012, 54 (03) :227-232
[7]   In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography [J].
Benic, Goran I. ;
Sancho-Puchades, Manuel ;
Jung, Ronald E. ;
Deyhle, Hans ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) :378-383
[8]   Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts [J].
Bezerra, I. S. Q. ;
Neves, F. S. ;
Vasconcelos, T. V. ;
Ambrosano, G. M. B. ;
Freitas, D. Q. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (06)
[9]   Multiple teeth replacement with endosseous one-piece yttrium-stabilized zirconia dental implants [J].
Borgonovo, Andrea-Enrico ;
Fabbri, Alberto ;
Vavassori, Virna ;
Censi, Rachele ;
Maiorana, Carlo .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2012, 17 (06) :E981-E987
[10]  
De Man B, 1999, IEEE T NUCL SCI, V46, P691, DOI 10.1109/23.775600