Simultaneous capillary electrophoresis of anions and cations in a single injection using an anion exchanger-modified capillary for determination of salivary ions in combination with statistical analyses

被引:11
作者
Mori, Masanobu [1 ]
Aoyagi, Keisuke [2 ]
Tomoda, Toshihiro [2 ]
Ishikawara, Fumi [2 ]
Sakamoto, Shou [2 ]
Myochin, Hironori [1 ]
Kuga, Midori [1 ]
Kozaki, Daisuke [1 ]
Ohshima, Noriyasu [3 ]
Izumi, Takashi [3 ,4 ]
Itabashi, Hideyuki [2 ]
Shoho, Yoshifumi [5 ]
Yoshida, Akihiro [6 ]
Tsunekawa, Katsuhiko [6 ]
Kimura, Takao [6 ]
Murakami, Masami [6 ]
机构
[1] Kochi Univ, Fac Sci & Technol, Dept Chem & Life Sci, 2-5-1 Akebono Cho, Kochi 7808520, Japan
[2] Gunma Univ, Grad Sch Sci & Technol, Dept Chem Engn, 1-5-1 Tenjin Cho, Kiryu, Gunma 3768515, Japan
[3] Gunma Univ, Grad Sch Med, Dept Biochem, Maebashi, Gunma 3718511, Japan
[4] Teikyo Heisei Univ, Fac Hlth Care, Toshima Ku, 2-51-4 Higashiikebukuro, Tokyo 1708445, Japan
[5] Ikuei Univ, Fac Educ, 1656-1 Kyoume Machi, Takasaki, Gunma 3700011, Japan
[6] Gunma Univ, Grad Sch Med, Dept Clin Lab Med, Maebashi, Gunma 3718511, Japan
基金
日本学术振兴会;
关键词
Capillary electrophoresis; Biochemical marker; Saliva; Physical stress; Multiple regression analysis; ALPHA-AMYLASE REACTIVITY; EXHALED NITRIC-OXIDE; INORGANIC ANIONS; HIGH MAGNITUDE; CORTISOL; STRESS; BLOOD; THIOCYANATE; SEPARATION; DIAGNOSIS;
D O I
10.1016/j.chroma.2020.461647
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the simultaneous capillary electrophoresis (CE) of anions and cations using an anion exchange-modified capillary, which was prepared by chemical coating with a cationic silylating reagent, and its application to saliva analysis. The CE method provides high-throughput (5 min for a single sample injection) analysis by generating a high-velocity electroosmotic flow at pH 3.0-3.5. The detection limits at a signal-to-noise ratio of 3 ranged from 1.2 to 18 mu M for anions and 1.0 to 2.7 mu M for cations. The relative standard deviations for the migration times and peak areas of analytes (n = 4) ranged from 0.05% to 0.40% and 0.94% to 4.7%, respectively. The CE system was used to analyze 11 common ions in saliva samples collected from long-distance runners and sedentary university students before and after running for a set distance or a set time. Interestingly, the SCN- concentrations decreased in the saliva samples of all 14 athletes and 16 sedentary students after running. Furthermore, when the concentrations of the analyzed ions were compared with that of cortisol as a typical stress marker by multiple regression analysis, SCN- and NO3- in saliva samples from the two subject groups strongly correlated with cortisol levels, as determined by an electrochemiluminescence immunoassay. This study improves our knowledge of both the analytical methodology for CE and statistical methods for identifying common ions that could be used as physical stress markers. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 59 条
  • [21] Simultaneous separation of anions and cations by capillary electrophoresis with high magnitude, reversed electroosmotic flow
    Johns, C
    Yang, WC
    Macka, M
    Haddad, PR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1050 (02) : 217 - 222
  • [22] Kallapur Basavaraj, 2013, J Nat Sci Biol Med, V4, P341, DOI 10.4103/0976-9668.117006
  • [23] Salivary cortisol levels are elevated in the afternoon and at bedtime in children with prenatal alcohol exposure
    Keiver, Kathy
    Bertram, Chris P.
    Orr, Alison Pritchard
    Clarren, Sterling
    [J]. ALCOHOL, 2015, 49 (01) : 79 - 87
  • [24] The nitric oxide system and cortisol-induced hypertension in humans
    Kelly, JJ
    Tam, SH
    Williamson, PM
    Lawson, J
    Whitworth, JA
    [J]. CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1998, 25 (11) : 945 - 946
  • [25] Simultaneous determination of small cations and anions by capillary electrophoresis
    Kuban, P
    Karlberg, B
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (02) : 360 - 365
  • [26] Direct analysis of formate in human plasma, serum and whole blood by in-line coupling of microdialysis to capillary electrophoresis for rapid diagnosis of methanol poisoning
    Kuban, Pavel
    Bocek, Petr
    [J]. ANALYTICA CHIMICA ACTA, 2013, 768 : 82 - 89
  • [27] Capillary electrophoresis - A new tool for ionic analysis of exhaled breath condensate
    Kuban, Petr
    Kobrin, Eeva-Gerda
    Kaljurand, Mihkel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 : 239 - 245
  • [28] Salivary Cortisol in Ambulatory Assessment-Some Dos, Some Don'ts, and Some Open Questions
    Kudielka, Brigitte M.
    Gierens, Andrea
    Hellhammer, Dirk H.
    Wuest, Stefan
    Schlotz, Wolff
    [J]. PSYCHOSOMATIC MEDICINE, 2012, 74 (04): : 418 - 431
  • [29] Capillary electrophoretic analysis of ionic content in exhaled breath condensate and pH monitoring as a non-invasive method in gastroesophageal reflux disease diagnostics
    Lacna, Julia
    Durc, Pavol
    Gregus, Michal
    Skrickova, Jana
    Doubkova, Martina
    Pokojova, Eva
    Kindlova, Dagmar
    Dolina, Jiri
    Konecny, Stefan
    Foret, Frantisek
    Kuban, Petr
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1134
  • [30] Optimization of background electrolyte composition for simultaneous contactless conductivity and fluorescence detection in capillary electrophoresis of biological samples
    Lacna, Julia
    Prikryl, Jan
    Teshima, Norio
    Murakami, Hiroya
    Esaka, Yukihiro
    Foret, Frantisek
    Kuban, Petr
    [J]. ELECTROPHORESIS, 2019, 40 (18-19) : 2390 - 2397