Assessment of shear capacity methods of steel fiber reinforced concrete beams using full scale prestressed bridge beams

被引:6
作者
Bendtsen, Bo [1 ]
Sanjayan, Jay G. [1 ]
机构
[1] Swinburne Univ Technol, Ctr Sustainable Infrastruct, Fac Sci Engn & Technol, Hawthorn, Vic 3122, Australia
关键词
Steel fibers; Concrete; Shear; Prestressed; Plastic method; fib Model Code; STIRRUPS; STRENGTH;
D O I
10.1617/s11527-014-0415-3
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel fiber addition in concrete is widely known to increase the non-flexural performance of concrete structures such as shear capacity. Design guides such as fib Model Code (2010) have recognised this effect and that these guidelines may become widely accepted. The current design guides are based on laboratory scale tests which may be compromised by the scale effects. This paper reports the results of full sized precast prestressed bridge beams that were fabricated and tested to shear failure. Two beams had steel fiber and two beams were plain concrete. None of the beams had any vertical shear reinforcements. The addition of steel fiber at the dosage of 60 kg per cubic metre resulted in more than twice the shear capacity as compared to the beams without steel fibers. The results of the fiber reinforced beams were compared with the calculated shear capacity of the fib Model Code (2010) and plastic design method. This paper presents a method to include prestress in previously developed plastic design method. The model code method predicted an increase of shear capacity of 22 % as compared to the experimental results of 112 % increase due to steel fiber addition. This demonstrates that the model code is not effective in taking into consideration of the contributions by steel fibers. The plastic design approach predicted an increase of shear capacity of 122 % which is close to the experimental values. Based on this full scale tests, the plastic design approach appears to be more suitable for estimation of shear capacity enhancement when steel fibers are used.
引用
收藏
页码:3473 / 3483
页数:11
相关论文
共 50 条
  • [21] ANN-Based Shear Capacity of Steel Fiber-Reinforced Concrete Beams without Stirrups
    Abambres, Miguel
    Lantsoght, Eva O. L.
    FIBERS, 2019, 7 (10)
  • [22] Decomposition of the Shear Capacity of Steel Fiber-Reinforced Concrete Coupling Beams
    Gao, Xiangling
    Xiang, Dong
    Li, Jie
    Ren, Xiaodan
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (11)
  • [23] Shear capacity assessment of reinforced concrete beams with corroded stirrups
    El-Sayed, Ahmed K.
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 134 : 176 - 184
  • [24] Shear behavior of prestressed precast beams made of self-compacting fiber reinforced concrete
    Cuenca, E.
    Serna, P.
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 45 : 145 - 156
  • [25] Reliability assessment of the behavior of reinforced and/or prestressed concrete beams sections in shear failure
    Benyahi, Karim
    Kachi, Mohand Said
    Bouafia, Youcef
    Barboura, Salma
    Li, Jia
    FRATTURA ED INTEGRITA STRUTTURALE-FRACTURE AND STRUCTURAL INTEGRITY, 2021, Gruppo Italiano Frattura (57): : 195 - 222
  • [26] Parametric Study on Shear Performance for Steel Fiber Reinforced Concrete Beams
    Seo, Junwon
    Lee, Jaeha
    Lopez, Maria M.
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (07) : 1115 - 1127
  • [27] Shear capacity analysis of fiber reinforced polymer concrete beams
    Mohammed Sharif
    Discover Civil Engineering, 1 (1):
  • [28] Flexure-Shear Behavior of Hybrid Fiber-Reinforced Prestressed Concrete Beams
    Joshi, Suhas S.
    Thammishetti, Nikesh
    Prakash, S. Suriya
    ACI STRUCTURAL JOURNAL, 2020, 117 (01) : 269 - 278
  • [29] Prediction of shear crack width for steel fiber reinforced concrete beams
    Negi, Bichitra Singh
    Jain, Kranti
    STRUCTURAL CONCRETE, 2022, 23 (02) : 1065 - 1079
  • [30] Assessment of Shear Capacity of Fiber-Reinforced Polymer Deep Beams Using Different Methods
    Alam, Md Shah
    ACI STRUCTURAL JOURNAL, 2021, 118 (06) : 237 - 250