Performance study of a PET scanner based on monolithic scintillators for different DoI-dependent methods

被引:3
作者
Preziosi, E. [1 ]
Sanchez, S. [2 ]
Gonzalez, A. J. [2 ]
Pani, R. [3 ]
Borrazzo, C. [4 ]
Bettiol, M. [5 ]
Rodriguez-Alvarez, M. J. [2 ]
Gonzalez-Montoro, A. [2 ]
Moliner, L. [2 ]
Benlloch, J. M. [2 ]
机构
[1] Sapienza Univ Rome, SAIMLAL Dept, Doctorate Sch Biol & Mol Med Morphofunct Sci Biop, Rome, Italy
[2] CSIC, I3M, Inst Instrumentat Mol Imaging, Valencia, Spain
[3] Sapienza Univ Rome, Dept Med Surg Sci & Biotechnol, Rome, Italy
[4] Sapienza Univ Rome, Dept Mol Med, Rome, Italy
[5] Campus Biomed Univ, Dept Radiotherapy, Rome, Italy
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Gamma detectors (scintillators CZT HPG HgI etc); Image reconstruction in medical imaging; Multi-modality systems; SIMULATION TOOLKIT; HIGH-RESOLUTION; GATE;
D O I
10.1088/1748-0221/11/12/C12076
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the technical objectives of the MindView project is developing a brain-dedicated PET insert based on monolithic scintillation crystals. It will be inserted in MRI systems with the purpose to obtain simultaneous PET and MRI brain images. High sensitivity, high image quality performance and accurate detection of the Depth-of-Interaction (DoI) of the 511keV photons are required. We have developed a DoI estimation method, dedicated to monolithic scintillators, allowing continuous DoI estimation and a DoI-dependent algorithm for the estimation of the photon planar impact position, able to improve the single module imaging capabilities. In this work, through experimental measurements, the proposed methods have been used for the estimation of the impact positions within the monolithic crystal block. We have evaluated the PET system performance following the NEMANU 4-2008 protocol by reconstructing the images using the STIR 3D platform. The results obtained with two different methods, providing discrete and continuous DoI information, are compared with those obtained from an algorithm without DoI capabilities and with the ideal response of the detector. The proposed DoI-dependent imaging methods show clear improvements in the spatial resolution (FWHM) of reconstructed images, allowing to obtain values from 2mm (at the center FoV) to 3mm (at the FoV edges).
引用
收藏
页数:12
相关论文
共 17 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
[Anonymous], NEMA STANDARDS PUBLI
[3]   Performance Evaluation of the Inveon Dedicated PET Preclinical Tomograph Based on the NEMA NU-4 Standards [J].
Bao, Qinan ;
Newport, Danny ;
Chen, Mu ;
Stout, David B. ;
Chatziioannou, Arion F. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (03) :401-408
[4]   Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scanner [J].
de Jong, Hugo W. A. M. ;
van Velden, Floris H. P. ;
Kloet, Reina W. ;
Buijs, Fred L. ;
Boellaard, Ronald ;
Lammertsma, Adriaan A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (05) :1505-1526
[5]  
Gonzalez A.J., 2016, IEEE NUCL SCI S C RE
[6]   The MINDView brain PET detector, feasibility study based on SiPM arrays [J].
Gonzalez, Antonio J. ;
Majewski, Stan ;
Sanchez, Filomeno ;
Aussenhofer, Sebastian ;
Aguilar, Albert ;
Conde, Pablo ;
Hernandez, Liczandro ;
Vidal, Luis E. ;
Pani, Roberto ;
Bettiol, Marco ;
Fabbri, Andrea ;
Bert, Julien ;
Visvikis, Dimitris ;
Jackson, Carl ;
Murphy, John ;
O'Neill, Kevin ;
Benlloch, Jose M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 818 :82-90
[7]   GATE:: a simulation toolkit for PET and SPECT [J].
Jan, S ;
Santin, G ;
Strul, D ;
Staelens, S ;
Assié, K ;
Autret, D ;
Avner, S ;
Barbier, R ;
Bardiès, M ;
Bloomfield, PM ;
Brasse, D ;
Breton, V ;
Bruyndonckx, P ;
Buvat, I ;
Chatziioannou, AF ;
Choi, Y ;
Chung, YH ;
Comtat, C ;
Donnarieix, D ;
Ferrer, L ;
Glick, SJ ;
Groiselle, CJ ;
Guez, D ;
Honore, PF ;
Kerhoas-Cavata, S ;
Kirov, AS ;
Kohli, V ;
Koole, M ;
Krieguer, M ;
van der Laan, DJ ;
Lamare, F ;
Largeron, G ;
Lartizien, C ;
Lazaro, D ;
Maas, MC ;
Maigne, L ;
Mayet, F ;
Melot, F ;
Merheb, C ;
Pennacchio, E ;
Perez, J ;
Pietrzyk, U ;
Rannou, FR ;
Rey, M ;
Schaart, DR ;
Schmidtlein, CR ;
Simon, L ;
Song, TY ;
Vieira, JM ;
Visvikis, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4543-4561
[8]  
Karp JS, 2003, J NUCL MED, V44, P1340
[9]   Technical performance evaluation of a human brain PET/MRI system [J].
Kolb, Armin ;
Wehrl, Hans F. ;
Hofmann, Matthias ;
Judenhofer, Martin S. ;
Eriksson, Lars ;
Ladebeck, Ralf ;
Lichy, Matthias P. ;
Byars, Larry ;
Michel, Christian ;
Schlemmer, Heinz-Peter ;
Schmand, Matthias ;
Claussen, Claus D. ;
Sossi, Vesna ;
Pichler, Bernd J. .
EUROPEAN RADIOLOGY, 2012, 22 (08) :1776-1788
[10]  
Levin A., 1996, IEEE NUCL SCI C R, V7, P702