Determination of celecoxib, a COX-2 inhibitor, in pharmaceutical dosage forms by MEKC

被引:24
作者
Srinivasu, MK
Rao, DS
Reddy, GO [1 ]
机构
[1] Dr Reddys Res Fdn, Dept Analyt Res, Hyderabad 500050, Andhra Pradesh, India
[2] Dr Reddys Labs, Technol Dev Ctr, Custom Chem Serv, Hyderabad 500050, Andhra Pradesh, India
关键词
celecoxib; MEKC; dosage form; validation; stability; RSD;
D O I
10.1016/S0731-7085(01)00670-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micellar electrokinetic chromatographic (MEKC) method was developed for the quantification of celecoxib, a COX-2 inhibitor in pharmaceutical dosage forms within the total analysis time of 7 min. The method has been validated and proven to be rugged. The quantification was carried out at 35 degreesC and 25 kV, using a 25 mM borate buffer (pH 9.3), 25 mM sodium dodecyl sulphate with an extended light path capillary (48.5 cm x 50 mum. I.D., 40 cm to detector). Calibration curves were constructed for celecoxib (0.2-0.6 mg/ml) by the internal standard method with 2-nitro aniline as an internal standard (coefficient of correlation greater than 0.999). The intermediate precision (between day precision) of migration times and peak area ratios of celecoxib to internal standard were 1.44 and 1.58% R.S.D., demonstrates good reproducibility of the method. The method was applied to a commercial celecoxib formulation (Revibra, 100 mg) and the percentage recoveries were ranged from 93.0 to 98.4%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 9 条
[1]   Micellar electrokinetic capillary chromatography as an alternative method for the determination of ethinylestradiol and levo-norgestrel [J].
Berzas, JJ ;
Del Castillo, B ;
Castañeda, G ;
Pinilla, MJ .
TALANTA, 1999, 50 (02) :261-268
[2]   A practical guide to analytical method validation [J].
Green, JM .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :A305-A309
[3]  
*ICH SECR, 1995, DRAFT GUID VAL PROC, V60
[4]  
MAHESH K, 2000, INDIAN DRUGS, V37, P524
[5]   LC separation of ortho and meta isomers of celecoxib in bulk and formulations using a chiral column [J].
Rao, DS ;
Srinivasu, MK ;
Narayana, CL ;
Reddy, GO .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (01) :21-30
[6]   Determination of celecoxib in human plasma by normal-phase high-performance liquid chromatography with column switching and ultraviolet absorbance detection [J].
Rose, MJ ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (02) :377-385
[7]   APPLICATION AND OPTIMIZATION OF CAPILLARY ZONE ELECTROPHORESIS IN VITAMIN ANALYSIS [J].
SCHIEWE, J ;
MRESTANI, Y ;
NEUBERT, R .
JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) :255-259
[8]   A validated LC method for the quantitative determination of celecoxib in pharmaceutical dosage forms and purity evaluation in bulk drugs [J].
Srinivasu, MK ;
Narayana, CL ;
Rao, DS ;
Reddy, GO .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (06) :949-956
[9]  
2000, DAILY DRUG NEWS 1023