Life cycle assessment of a large water treatment plant in Turkey

被引:24
作者
Saad, Alaa [1 ]
Elginoz, Nilay [2 ]
Babuna, Fatos Germirli [1 ]
Iskender, Gulen [1 ]
机构
[1] Istanbul Tech Univ, Dept Environm Engn, TR-34469 Istanbul, Turkey
[2] Istanbul Tech Univ, Dept Civil Engn, TR-34469 Istanbul, Turkey
关键词
Water treatment; Environmental impacts; Life cycle assessment; Operation; Sustainability; ENVIRONMENTAL ASSESSMENT; PERFORMANCE; ELECTRICITY; DESIGN; TOOL; LCA;
D O I
10.1007/s11356-018-3826-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study is to assess the environmental sustainability of a large water treatment plant through life cycle assessment (LCA) approach. This study is a pioneering one that explores the environmental impacts of a water treatment plant in Turkey by using the data collected from an actual plant. Decision makers of the treatment plant under investigation, operators of similar installations, and the scientific researchers that work on LCA of water treatment facilities are defined as the target audience. GaBi software is used for the LCA model, and CML 2001 method is adopted to calculate the results given per 1m(3) water ready to be distributed to the city. The plant serves about 2,600,000 people generating a maximum potable water flow rate of 400,000m(3)/day. In the facility, 0.57kWh of electricity is required to obtain 1m(3) of water. Of this total electricity consumption, 85% is allocated to inlet and outlet pumping stations. The results denote that the environmental impacts are dominated by electricity consumption that in turn depends on the energy source/s adopted. Sensitivity analysis on energy sources reveals the following outcomes: In case of using hard coal as energy source rather than grid mix, impacts are increased apart from freshwater aquatic ecotoxicity potential, ozone layer depletion potential, and abiotic depletion potential elements. Once solar panels are used instead of grid mix, values for all impact categories except abiotic depletion potential elements and human toxicity potential are lowered. The usage of wind turbines in place of grid mix results in 29 to 84% reductions in all investigated impact categories. The best option to decrease the environmental impacts is attained when energy is generated using wind turbines. As pumps having 90% efficiency replace the pumps with 60% efficiency, reductions ranging from 15 to 24% on all impact categories are obtained. The work performed for this study should be further pursued to obtain more representative inventory data for countries with scarce LCA studies.
引用
收藏
页码:14823 / 14834
页数:12
相关论文
共 39 条
  • [1] [Anonymous], 2017, SOLAREX MAGAZINE
  • [2] An integrated life cycle sustainability assessment of electricity generation in Turkey
    Atilgan, Burcin
    Azapagic, Adisa
    [J]. ENERGY POLICY, 2016, 93 : 168 - 186
  • [3] Renewable electricity in Turkey: Life cycle environmental impacts
    Atilgan, Burcin
    Azapagic, Adisa
    [J]. RENEWABLE ENERGY, 2016, 89 : 649 - 657
  • [4] Life cycle environmental impacts of electricity from fossil fuels in Turkey
    Atilgan, Burcin
    Azapagic, Adisa
    [J]. JOURNAL OF CLEANER PRODUCTION, 2015, 106 : 555 - 564
  • [5] Life cycle assessment and cost analysis of residential buildings in south east of Turkey: part 1-review and methodology
    Atmaca, Adem
    [J]. INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2016, 21 (06) : 831 - 846
  • [6] Life-cycle assessment of post-disaster temporary housing
    Atmaca, Nihat
    [J]. BUILDING RESEARCH AND INFORMATION, 2017, 45 (05) : 524 - 538
  • [7] Life cycle assessment as a decision support tool in wastewater treatment plant design with renewable energy utilization
    Baskurt, Muratcan
    Kocababuc, Ilgin
    Binici, Esra
    Dulekgurgen, Ebru
    Ozgun, Ozlem Karahan
    Tasli, Ruya
    [J]. DESALINATION AND WATER TREATMENT, 2017, 93 : 229 - 238
  • [8] Life cycle assessment of cotton textile products in Turkey
    Baydar, G.
    Ciliz, N.
    Mammadov, A.
    [J]. RESOURCES CONSERVATION AND RECYCLING, 2015, 104 : 213 - 223
  • [9] Performance of a coagulation-ultrafiltration hybrid process for water supply treatment
    Bergamasco, Rosangela
    Konradt-Moraes, Leila Cristina
    Vieira, Marcelo Fernandes
    Fagundes-Klen, Marcia Regina
    Salcedo Vieira, Angelica Marquetotti
    [J]. CHEMICAL ENGINEERING JOURNAL, 2011, 166 (02) : 483 - 489
  • [10] Improving the carbon footprint of water treatment with renewable energy: a Western Australian case study
    Wahidul K. Biswas
    Pauline Yek
    [J]. Renewables: Wind, Water, and Solar, 3 (1):