A New Technique for Radiographic Measurement of Acetabular Cup Orientation

被引:17
作者
Derbyshire, Brian [1 ]
Diggle, Peter J. [2 ]
Ingham, Christopher J. [3 ]
Macnair, Rory [3 ]
Wimhurst, James [3 ]
Jones, Henry Wynn [1 ]
机构
[1] Wrightington Hosp, Appley Bridge WN6 9EP, England
[2] Univ Lancaster, Lancaster LA1 4YW, England
[3] Norfolk & Norwich Univ Hosp, Norwich, Norfolk, England
关键词
acetabular cup; radiographic measurement; cup inclination; cup version; cup orientation; TOTAL-HIP-ARTHROPLASTY; RESURFACING ARTHROPLASTY; REPLACEMENT; VERSION; WEAR; POSITIONS; COMPONENT;
D O I
10.1016/j.arth.2013.06.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:369 / 372
页数:4
相关论文
共 25 条
  • [1] Influence of cup orientation on the wear performance of metal-on-metal hip replacements
    Angadji, A.
    Royle, M.
    Collins, S. N.
    Shelton, J. C.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H4) : 449 - 457
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] CLARKE IC, 1976, CLIN ORTHOP RELAT R, P83
  • [4] MEDICAL DEVICES Out of joint: The story of the ASR
    Cohen, Deborah
    [J]. BRITISH MEDICAL JOURNAL, 2011, 342
  • [5] Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement
    De Haan, R.
    Pattyn, C.
    Gill, H. S.
    Murray, D. W.
    Campbell, P. A.
    De Smet, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10): : 1291 - 1297
  • [6] Correction of acetabular cup orientation measurements for X-ray beam offset
    Derbyshire, Brian
    [J]. MEDICAL ENGINEERING & PHYSICS, 2008, 30 (09) : 1119 - 1126
  • [7] Eddine TA, 2001, SURG RADIOL ANAT, V23, P105
  • [8] CT Outperforms Radiography for Determination of Acetabular Cup Version after THA
    Ghelman, Bernard
    Kepler, Christopher K.
    Lyman, Stephen
    Della Valle, Alejandro Gonzalez
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) : 2362 - 2370
  • [9] Optimal acetabular orientation for hip resurfacing
    Grammatopoulos, G.
    Pandit, H.
    Glyn-Jones, S.
    McLardy-Smith, P.
    Gundle, R.
    Whitwell, D.
    Gill, H. S.
    Murray, D. W.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08): : 1072 - 1078
  • [10] Metal-on-metal bearings THE EVIDENCE SO FAR
    Haddad, F. S.
    Thakrar, R. R.
    Hart, A. J.
    Skinner, J. A.
    Nargol, A. V. F.
    Nolan, J. F.
    Gill, H. S.
    Murray, D. W.
    Blom, A. W.
    Case, P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05): : 572 - 579