Are Patients More Satisfied With a Balanced Total Knee Arthroplasty?

被引:68
作者
Golladay, Gregory J. [1 ]
Bradbury, Thomas L. [2 ]
Gordon, Alexander C. [3 ]
Fernandez-Madrid, Ivan J. [4 ]
Krebs, Viktor E. [5 ]
Patel, Preetesh D. [6 ]
Suarez, Juan C. [6 ,7 ]
Rueda, Carlos A. Higuera [6 ]
Barsoum, Wael K. [6 ]
机构
[1] Virginia Commonwealth Univ Hlth, Dept Orthopaed Surg, 1200 E Broad St,Box 980153, Richmond, VA 23298 USA
[2] Emory Healthcare, Dept Orthopaed Surg, Atlanta, GA USA
[3] Illinois Bone & Joint Inst, Morton Grove, IL USA
[4] NYU Langone Hlth, NYU Orthopaed Surg Associates, New York, NY USA
[5] Cleveland Clin Fdn A41, Dept Orthopaed Surg, Cleveland, OH USA
[6] Cleveland Clin Florida, Dept Orthopaed Surg, Weston, FL USA
[7] Baptist Hlth South Florida, Miami Orthopaed & Sports Med Inst, Miami, FL USA
关键词
total knee arthroplasty; forgotten joint; satisfaction; soft tissue balance; intraoperative sensors; FORGOTTEN JOINT; SATISFACTION; REPLACEMENT; VALIDATION; REVISION; OUTCOMES;
D O I
10.1016/j.arth.2019.03.036
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patient-reported outcome measures are increasingly recognized as an important tool in quantifying the clinical success of arthroplasty surgery. The aim of this study is to measure postoperative joint awareness and satisfaction in patients with and without a quantitatively balanced knee following primary total knee arthroplasty (TKA). Methods: In this multi-center study, a total of 318 eligible patients were assigned to one of the 2 patient groups: sensor-guided TKA or surgeon-guided TKA. In the sensor-guided group, quantitative balancing was performed according to intercompartmental tibiofemoral load measurements measured by an instrumented tibial trial component. In contrast, for the surgeon-guided group, the knees were balanced according to the surgeons' standard manual techniques while blinding the surgeon to the sensor measurements. Patients were blinded to their allocation and filled out the validated Forgotten Joint Score and 2011 Knee Society Satisfaction questionnaires at 6 weeks and 6 months. For the purposes of this study, the subjects were pooled and stratified by their state of soft tissue balance, based on the mediolateral load differential through the range of motion. Results: In the surgeon-guided group, approximately 50% of the cases yielded a quantitatively balanced knee. Significantly more balanced knees were observed in the sensor-guided group (84.0%). More importantly, for both outcome measures, the balanced group of patients reported significantly better outcomes scores. Conclusion: This demonstrates that using sensor feedback during knee arthroplasty surgery results in a more reproducible procedure, resulting in a higher percentage of balanced patients who in turn demonstrate superior clinical outcomes compared to unbalanced patients. (c) 2019 Published by Elsevier Inc.
引用
收藏
页码:S195 / S200
页数:6
相关论文
共 31 条
  • [11] The Use of Electronic Sensor Device to Augment Ligament Balancing Leads to a Lower Rate of Arthrofibrosis After Total Knee Arthroplasty
    Geller, Jeffrey A.
    Lakra, Akshay
    Murtaugh, Taylor
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (05) : 1502 - 1504
  • [12] Soft tissue balancing in total knee arthroplasty using sensor-guided assessment: is there a learning curve?
    Gharaibeh, Monther A.
    Chen, Darren B.
    MacDessi, Samuel J.
    [J]. ANZ JOURNAL OF SURGERY, 2018, 88 (05) : 497 - 501
  • [13] Increased satisfaction after total knee replacement using sensor-guided technology
    Gustke, K. A.
    Golladay, G. J.
    Roche, M. W.
    Jerry, G. J.
    Elson, L. C.
    Anderson, C. R.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (10) : 1333 - 1338
  • [14] Primary TKA Patients with Quantifiably Balanced Soft-Tissue Achieve Significant Clinical Gains Sooner than Unbalanced Patients
    Gustke, Kenneth A.
    Golladay, Gregory J.
    Roche, Martin W.
    Elson, Leah C.
    Anderson, Christopher R.
    [J]. ADVANCES IN ORTHOPEDICS, 2014, 2014
  • [15] A Targeted Approach to Ligament Balancing Using Kinetic Sensors
    Gustke, Kenneth A.
    Golladay, Gregory J.
    Roche, Martin W.
    Elson, Leah C.
    Anderson, Christopher R.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (07) : 2127 - 2132
  • [16] A New Method for Defining Balance: Promising Short-Term Clinical Outcomes of Sensor-Guided TKA
    Gustke, Kenneth A.
    Golladay, Gregory J.
    Roche, Martin W.
    Elson, Leah C.
    Anderson, Christopher R.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (05) : 955 - 960
  • [17] Validation of the English language Forgotten Joint Score-12 as an outcome measure for total hip and knee arthroplasty in a British population
    Hamilton, D. F.
    Loth, F. L.
    Giesinger, J. M.
    Giesinger, K.
    MacDonald, D. J.
    Patton, J. T.
    Simpson, A. H. R. W.
    Howie, C. R.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (02) : 218 - 224
  • [18] Health-related quality of life after knee replacement - Results of the Knee Replacement Patient Outcomes Research Team Study
    Hawker, G
    Wright, J
    Coyte, P
    Paul, J
    Dittus, R
    Croxford, R
    Katz, B
    Bombardier, C
    Heck, D
    Freund, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (02) : 163 - 173
  • [19] Impact of the Economic Downturn on Total Joint Replacement Demand in the United States
    Kurtz, Steven M.
    Ong, Kevin L.
    Lau, Edmund
    Bozic, Kevin J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (08) : 624 - 630
  • [20] The Learning Curve by Operative Time for Soft Tissue Balancing in Total Knee Arthroplasty Using Electronic Sensor Technology
    Lakra, Akshay
    Sarpong, Nana O.
    Jennings, Emma L.
    Grosso, Matthew J.
    Cooper, H. John
    Shah, Roshan P.
    Geller, Jeffrey A.
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (03) : 483 - 487