Accuracy and precision assessment of a new blood glucose monitoring system

被引:6
|
作者
Ji, Li-Nong [1 ]
Guo, Li-Xin [2 ]
Liu, Li-Bin [3 ]
机构
[1] Peking Univ, Peoples Hosp, Beijing 100044, Peoples R China
[2] Peking Univ, Dept Endocrinol, Beijing 100044, Peoples R China
[3] Fujian Union Hosp, Dept Endocrinol, Fuzhou, Peoples R China
关键词
accuracy; blood glucose; blood glucose monitoring system; precision; self-monitoring of blood glucose; PERFORMANCE; METERS;
D O I
10.1515/cclm-2015-0130
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Blood glucose self-monitoring by individuals with diabetes is essential in controlling blood glucose levels. The International Organization for Standardization (ISO) introduced new standards for blood glucose monitoring systems (BGMS) in 2013 (ISO 15197: 2013). The CONTOUR PLUS (R) (CONTOUR PLUS) BGMS has been demonstrated to meet the 2013 ISO standards; however, no Chinese data on CONTOUR PLUS accuracy and precision have been published. Methods: This study evaluated the accuracy and precision of CONTOUR PLUS BGMS in quantitative glucose testing of capillary and venous whole blood samples obtained from 363 patients at three different hospitals. Results: Results of fingertip and venous blood glucose measurements by the CONTOUR PLUS system were compared with laboratory reference values to determine accuracy. Accuracy was 98.1% (96.06%-99.22%) for fingertip blood tests and 98.1% (96.02%-99.21%) for venous blood tests. Precision was evaluated across a wide range of blood glucose values (5.1-17.2 mmol/L), testing three blood samples repeatedly 15 times with the CONTOUR PLUS blood glucose meter using test strips from three lots. All within-lot results met ISO criteria (i.e., SD < 0.42 mmol/L for blood glucose concentration < 5.55 mmol/L; CV < 7.5% for blood glucose concentration >= 5.55 mmol/L). Between-lot variations were 1.5% for low blood glucose concentration, 2.4% for normal and 3.4% for high. Conclusions: Accuracy of both fingertip and venous blood glucose measurements by the CONTOUR PLUS system was > 95%, confirming that the system meets ISO 15197: 2013 requirements.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 50 条
  • [1] Comparative System Accuracy of Blood Glucose Monitoring Systems-Advocacy for a New Accuracy Assessment Metric
    Kenning, Matthes
    Puchert, Anselm
    Salzsieder, Eckhard
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025, 19 (01): : 270 - 271
  • [2] Accuracy of a New Blood Glucose Monitoring System in the Hands of Users
    Wallace, Jane F.
    Yu, Ji
    Pardo, Scott
    Brown, Daniel
    Parkes, Joan Lee
    DIABETES, 2012, 61 : A590 - A590
  • [3] Accuracy and User Performance of a New Blood Glucose Monitoring System
    Klaff, Leslie
    Shelat, Pragathi
    Zondorak, Diana
    Wayland-Smith, Amy
    Vernes, Phil
    Richardson, James M.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (06): : 1382 - 1389
  • [4] EVALUATION OF USER PERFORMANCE AND ACCURACY OF A NEW BLOOD GLUCOSE MONITORING SYSTEM
    Christiansen, M.
    Shelat, P.
    Zondorak, D.
    Wayland-Smith, A.
    Vernes, P.
    Richardson, J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A109 - A109
  • [5] System Accuracy Evaluation of a Blood Glucose Monitoring System
    Kenning, Matthes
    Puchert, Anselm
    Salzsieder, Eckhard
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (02): : 574 - 575
  • [6] Accuracy and Precision of the CONTOUR® PLUS Blood Glucose Monitoring System as Used by Health Care Professionals
    Ji, Linong
    Guo, Lixin
    Pardo, Scott
    Huang, April
    Yeo, Sandy
    DIABETES, 2014, 63 : A596 - A596
  • [7] Accuracy and ease of use of a new blood glucose monitoring system and examination of the sample glucose distribution
    Leatherdale, B
    Bartley, E
    DIABETOLOGIA, 2004, 47 : A315 - A315
  • [8] Accuracy and precision of the MediSense Precision G blood glucose testing system.
    Zamoth, D
    Cembrowski, G
    McNeil, L
    Fineberg, SE
    Gibson, R
    CLINICAL CHEMISTRY, 1996, 42 (06) : 250 - 250
  • [9] Accuracy of the CONTOUR® Link Blood Glucose Monitoring System
    Harrison, Bern
    Halldorsdottir, Solveig
    DIABETES, 2011, 60 : A240 - A240
  • [10] ACCURACY, PRECISION, AND USER PERFORMANCE EVALUATION OF THE CONTOUR® NEXT LINK 2.4 BLOOD GLUCOSE MONITORING SYSTEM
    Bailey, T.
    Klaff, L. J.
    Wallace, J. F.
    Greene, C.
    Pardo, S.
    Brown, D.
    Pflug, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A62 - A62