Tandem ICP-mass spectrometry for Sr isotopic analysis without prior Rb/Sr separation

被引:57
作者
Bolea-Fernandez, Eduardo [1 ]
Balcaen, Lieve [1 ]
Resano, Martin [2 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
[2] Univ Zaragoza, Dept Analyt Chem, Aragon Inst Engn Res I3A, E-50009 Zaragoza, Spain
关键词
DYNAMIC REACTION CELL; LONG-LIVED RADIONUCLIDES; RATIO MEASUREMENTS; METHYL-FLUORIDE; ENVIRONMENTAL-SAMPLES; REACTION GAS; MS; INTERFERENCE; RESOLUTION; BIAS;
D O I
10.1039/c5ja00157a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of a mixture of 10% of CH3F and 90% of He as a reaction gas in tandem ICP-mass spectrometry (ICP-MS/MS) enables the accurate determination of the Sr-87/Sr-86 isotope ratio in geological materials, provided that mass discrimination is corrected for by using a combination of internal (Russell law, assuming a constant Sr-88/Sr-86 isotope ratio) and external correction (using the isotopic reference material NIST SRM 987 SrCO3) in a sample-standard bracketing approach. No prior Rb/Sr separation is required as the isobaric overlap at a mass-to-charge ratio of 87 is avoided by monitoring SrF+ reaction product ions instead of Sr+ ions. Rb shows no reactivity towards CH3F. The double mass selection (MS/MS mode) prevents both spectral overlap from atomic ions at the mass-to-charge ratios of SrF+ reaction product ions and a measurable effect from the matrix on the Sr-87/Sr-86 result. This aspect is critical, as it enables accurate results to be obtained without the need for using a matrix-matched standard to correct for mass discrimination, in contrast to previous work with a quadrupole ICP-MS instrument with a CH3F/Ne-pressurized cell, in which the use of a matrix-matched standard was compulsory. The precision attainable -0.05% RSD external precision - suffices for making the newly developed method useful in a variety of applications.
引用
收藏
页码:303 / 310
页数:8
相关论文
共 51 条
[11]   Interference-free determination of ultra-trace concentrations of arsenic and selenium using methyl fluoride as a reaction gas in ICP-MS/MS [J].
Bolea-Fernandez, Eduardo ;
Balcaen, Lieve ;
Resano, Martin ;
Vanhaecke, Frank .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (03) :919-929
[12]   Potential of Methyl Fluoride as a Universal Reaction Gas to Overcome Spectral Interference in the Determination of Ultratrace Concentrations of Metals in Biofluids Using Inductively Coupled Plasma-Tandem Mass Spectrometry [J].
Bolea-Fernandez, Eduardo ;
Balcaen, Lieve ;
Resano, Martin ;
Vanhaecke, Frank .
ANALYTICAL CHEMISTRY, 2014, 86 (15) :7969-7977
[13]   Determination of 236U/238U isotope ratio in contaminated environmental samples using different ICP-MS instruments [J].
Boulyga, SF ;
Matusevich, JL ;
Mironov, VP ;
Kudrjashov, VP ;
Halicz, L ;
Segal, I ;
McLean, JA ;
Montaser, A ;
Becker, JS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :958-964
[14]   ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe, and Se [J].
Boulyga, SF ;
Becker, JS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :618-623
[15]   Strontium isotopes as tracers of ecosystem processes: theory and methods [J].
Capo, RC ;
Stewart, BW ;
Chadwick, OA .
GEODERMA, 1998, 82 (1-3) :197-225
[16]   Determination of chromium in water and urine by reaction cell inductively coupled plasma mass spectrometry [J].
Chang, YL ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) :1434-1438
[17]   On the chemical resolution of the 87Rb+ (s0)/87Sr+ (s1) isobaric interference:: A kinetic search for an optimum reagent [J].
Cheng, Ping ;
Koyanagi, Gregory K. ;
Bohme, Diethard K. .
ANALYTICA CHIMICA ACTA, 2008, 627 (01) :148-153
[18]   Classifying wine according to geographical origin via quadrupole-based ICP-mass spectrometry measurements of boron isotope ratios [J].
Coetzee, PP ;
Vanhaecke, F .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (06) :977-984
[19]   Systematic evaluation of a strontium-specific extraction chromatographic resin for obtaining a purified Sr fraction with quantitative recovery from complex and Ca-rich matrices [J].
De Muynck, David ;
Huelga-Suarez, Gonzalo ;
Van Heghe, Lana ;
Degryse, Patrick ;
Vanhaecke, Frank .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) :1498-1510
[20]   Triple Quad ICPMS (ICPQQQ) as a New Tool for Absolute Quantitative Proteomics and Phosphoproteomics [J].
Diez Fernandez, Silvia ;
Sugishama, Naoki ;
Ruiz Encinar, Jorge ;
Sanz-Medel, Alfredo .
ANALYTICAL CHEMISTRY, 2012, 84 (14) :5851-5857