Evaluation of surface and volume rendering in 3D-CT of facial fractures

被引:38
|
作者
Rodt, T.
Bartling, S. O.
Zajaczek, J. E.
Vafa, M. A.
Kapapa, T.
Majdani, O.
Krauss, J. K.
Zumkeller, M.
Matthies, H.
Becker, H.
Kaminsky, J.
机构
[1] Hannover Med Sch, Dept Neurosurg, Hannover, Germany
[2] Hannover Med Sch, Dept Neuroradiol, Hannover, Germany
[3] Hannover Med Sch, Dept Radiol, Hannover, Germany
[4] Hannover Med Sch, Dept Otorhinolaryngol, Hannover, Germany
[5] Hannover Med Sch, Dept Med Informat, Hannover, Germany
[6] Univ Tubingen, Sch Med, Dept Neurosurg, D-72074 Tubingen, Germany
关键词
computed tomography (CT); three-dimensional; facial fractures; images; processing; bones; CT;
D O I
10.1259/dmfr/22989395
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Three-dimensional computed tomography (3D-CT) of facial fractures has been reported as beneficial using surface (SR) and volume rendering (VR). There are controversial statements concerning the preferable algorithm. The purpose of this study was to evaluate and compare SR and VR for clinical 3D-CT in facial fractures on an experimental basis. Methods: Multislice CT was obtained in 22 patients with facial fractures using two data acquisition protocols. Five SR and VR post-processing protocols were applied. Five assessors independently evaluated the quality of visualization of the fracture gap and dislocated fragments as well as the overall image quality using a five-point rating scale. The potential benefit of the 3D-images for radiological diagnosis and presentation was evaluated. The influence of the data acquisition protocol was analysed. Results: SR in general achieved better evaluation scores than VR at corresponding thresholds. Variation of evaluation scores for all criteria was found for SR and VR depending on the segmentation threshold. Apart from the overall image quality no significant influence of the data acquisition technique was found for the evaluated criteria. Conclusions: SR provided sufficient and time efficient means for 3D-visualization of facial fractures in this study. No diagnostic benefit of VR over SR was found.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 50 条
  • [1] 3D CT of fractures: Comparison of volume rendering and surface rendering.
    Rieker, O
    Mildenberger, P
    Rudig, L
    Schweden, F
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (05): : 490 - 494
  • [2] 3D-CT evaluation of facial asymmetry
    Katsumata, A
    Fujishita, M
    Maeda, M
    Ariji, Y
    Ariji, E
    Langlais, RP
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2005, 99 (02): : 212 - 220
  • [3] 3D-CT angiography with volume rendering technique in the intracerebral aneurysms
    Sahel, M
    Ourrad, E
    Zouaoui, A
    Marro, B
    Sourour, N
    Biondi, A
    Casasco, A
    Marsault, C
    JOURNAL DE RADIOLOGIE, 2000, 81 (02): : 127 - 132
  • [4] Anthropometric analysis using 3D-CT volume rendering for craniofacial application
    Cavalcanti, MP
    Rocha, SS
    Ramos, DP
    Vannier, MW
    RADIOLOGY, 2002, 225 : 565 - 565
  • [5] Evaluation of sensitivity of 3D-CT for diagnosis of craniofacial fractures
    Cavalcanti, MGP
    Silva, APACE
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1116 - 1116
  • [6] COMPARISON BETWEEN RENDERING 3D-CT AND TRANSPARENT 3D-CT IN ACL TUNNEL POSITIONING
    Barros, Marcos Amstalden
    Fernandes, Tiago Lazzaretti
    Dimitriou, Dimitris
    Pedrinelli, Andre
    Hernandez, Arnaldo Jose
    ACTA ORTOPEDICA BRASILEIRA, 2017, 25 (01): : 30 - 33
  • [7] Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications
    Cavalcanti, MGP
    Rocha, SS
    Vannier, MW
    DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (03) : 170 - 176
  • [8] 3D-CT evaluation of facial asymmetry in patients with maxillofacial deformities
    Maeda, Masahito
    Katsumata, Akitoshi
    Ariji, Yoshiko
    Muramatsu, Atsushi
    Yoshida, Kenji
    Goto, Shigemi
    Kurita, Kenichi
    Ariji, Eiichiro
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (03): : 382 - 390
  • [9] Skeletal 3-D CT: Advantages of volume rendering over surface rendering
    Kuszyk, BS
    Heath, DG
    Bliss, DF
    Fishman, EK
    SKELETAL RADIOLOGY, 1996, 25 (03) : 207 - 214
  • [10] Occipital sutures and its variations: the value of 3D-CT and how to differentiate it from fractures using 3D-CT?
    Choudhary, Arabinda Kumar
    Jha, Bhawna
    Boal, Danielle K.
    Dias, Mark