A homogeneous immunosensor for AFB1 detection based on FRET between different-sized quantum dots

被引:87
|
作者
Xu, Wei [1 ,2 ]
Xiong, Yonghua [1 ,2 ]
Lai, Weihua [1 ]
Xu, Yang [1 ,2 ]
Li, Changming [3 ,4 ]
Xie, Mingyong [1 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Peoples R China
[2] Nanchang Univ, Jiangxi OAI Joint Res Inst, Nanchang 330047, Peoples R China
[3] Southwest Univ, Fac Mat & Energy, Chongqing 400715, Peoples R China
[4] Southwest Univ, ICEAM, Chongqing 400715, Peoples R China
关键词
Fluorescence resonance energy transfer; Quantum dots; Aflatoxin B-1; Quantitative immunoassay; RESONANCE ENERGY-TRANSFER; IMMUNOCHROMATOGRAPHIC ASSAY; AFLATOXIN B-1; IMMUNOASSAY; FLUORESCENCE; SENSOR; FOODS;
D O I
10.1016/j.bios.2014.01.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Mycotoxins are fatal threats in food safety due to their strong carcinogenesis and toxicity, thus requiring highly sensitive detections. Herein, different-sized quantum dots (QDs) were used to construct a Forster resonance energy transfer (FRET) based immunosensor for sensitive detection of aflatoxin B-1 (AFB(1)) in rice grains. To avoid irregular aggregation between two kinds of QDs, monovalent monoclonal antibody (mAb)-labeled red QDs (similar to 0.84 anti-AFB(1) mAbs per QD) and multivalent hapten-labeled green QDs (similar to 6.8 AFB(1) per QD) were designed as acceptor and donor, respectively. The anti-AFB(1) mAbs and AFB(1) interactions promoted one or more acceptors bound with a multivalent AFB(1)-labeled donor, resulting in energy transfer from the green QDs to the red QDs. Various parameters that influence the immunoassay including reactant ratio of donor to acceptor, buffer pH value, buffer ionic strength and immunoreaction time were systematically investigated and optimized. With optimal conditions, the obtained energy transfer efficiency is proportional to the logarithm of AFB(1) concentration in a range over 0.19-16 pM (0.06-5 ng/mL), while offering a limit of detection of 0.13 pM (0.04 ng/mL) in rice extracts. The recovery rates of the intra-assay for spiked samples at AFB(1) concentrations of 0.1, 1.0, and 5.0 ng/mL were 83.27% +/- 3.27%, 97.36% +/- 4.55% and 83.04% +/- 4.94%, respectively, and those for the inter-assay were 81.28% +/- 6.11%, 95.97% +/- 7.07%, and 82.78% +/- 5.99%, respectively. Statistical analysis using t-test had no significant difference between the proposed FRET-based immunoassay and the commercial enzyme-linked immunosorbent assay kit. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [41] A sandwich immunoassay for detection of Aβ1-42 based on quantum dots
    Pi, Jiangli
    Long, Yijuan
    Huang, Ning
    Cheng, Yuan
    Zheng, Huzhi
    TALANTA, 2016, 146 : 10 - 15
  • [42] A facile dual-mode SERS/fluorescence aptasensor for AFB1 detection based on gold nanoparticles and magnetic nanoparticles
    Gao, Xueying
    Liu, Ying
    Wei, Jinxiang
    Wang, Zhouping
    Ma, Xiaoyuan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 315
  • [43] Label-free Electrochemiluminescent Immunosensor for Detection of Prostate Specific Antigen based on Aminated Graphene Quantum Dots and Carboxyl Graphene Quantum Dots
    Wu, Dan
    Liu, Yixin
    Wang, Yaoguang
    Hu, Lihua
    Ma, Hongmin
    Wang, Guoqin
    Wei, Qin
    SCIENTIFIC REPORTS, 2016, 6
  • [44] Electrochemiluminescence immunosensor based on signal probe CuFeS2 quantum Dots for ultrasensitive detection of cyclin D1
    Yang, Anzi
    Huangfu, Xiaoxia
    Liu, Lixiao
    Luo, Wen
    Zhao, Wenbo
    Yin, Jun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 871
  • [45] A signal-enhancement fluorescent aptasensor based on the stable dual cross DNA nanostructure for simultaneous detection of OTA and AFB1
    Zhiguang Suo
    Xiujun Liang
    Huali Jin
    Baoshan He
    Min Wei
    Analytical and Bioanalytical Chemistry, 2021, 413 : 7587 - 7595
  • [46] Bidirectional hybridized hairpin DNA fluorescent aptasensor based on Au-Pd NPs and CDs for ratiometric detection of AFB1
    Xu, Hongyan
    Zhao, Luyang
    Wan, Zhigang
    Liu, Yong
    Wei, Min
    MICROCHIMICA ACTA, 2024, 191 (08)
  • [47] A novel Nb2C MXene based aptasensor for rapid and sensitive multi-mode detection of AFB1
    Kong, Yiqian
    Li, Zongyi
    Zhang, Lili
    Song, Juncheng
    Liu, Qi
    Zhu, Yinghua
    Li, Na
    Song, Lili
    Li, Xiangyang
    BIOSENSORS & BIOELECTRONICS, 2023, 242
  • [48] A novel sandwiched electrochemiluminescence immunosensor for the detection of carcinoembryonic antigen based on carbon quantum dots and signal amplification
    Li, Nian-Lu
    Jia, Li-Ping
    Ma, Rong-Na
    Jia, Wen-Li
    Lu, Yi-Yang
    Shi, Sha-Shan
    Wang, Huai-Sheng
    BIOSENSORS & BIOELECTRONICS, 2017, 89 : 453 - 460
  • [49] An efficient turn-on fluorescence biosensor for the detection of glutathione based on FRET between N,S dual-doped carbon dots and gold nanoparticles
    Dong, Wenjuan
    Wa, Ruiping
    Gong, Xiaojuan
    Dong, Chuan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (25) : 6687 - 6695
  • [50] A novel BRCA1 gene deletion detection in human breast carcinoma MCF-7 cells through FRET between quantum dots and silver nanoclusters
    Borghei, Yasaman-Sadat
    Hosseini, Morteza
    Ganjali, Mohammad Reza
    Hosseinkhani, Saman
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 152 : 81 - 88