Tear Film Surface Quality With Soft Contact Lenses Using Dynamic-Area High-Speed Videokeratoscopy

被引:28
作者
Alonso-Caneiro, David [1 ]
Iskander, Robert [1 ]
Collins, Michael J. [1 ]
机构
[1] Queensland Univ Technol, Contact Lens & Visual Opt Lab, Sch Optometry, Brisbane, Qld 4001, Australia
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2009年 / 35卷 / 05期
关键词
Tear dynamics; Noninvasive methods; Dynamic videokeratography; HIGHER-ORDER ABERRATIONS; DRY EYE; LIPID LAYER; STABILITY; TIME; INTERFERENCE; TOPOGRAPHY; PHYSIOLOGY; DIAGNOSIS; BREAKUP;
D O I
10.1097/ICL.0b013e3181b3350f
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To evaluate the performance of the dynamic-area high-speed videokeratoscopy technique in the assessment of tear film surface quality with and without the presence of soft contact lenses on eye. Methods: Retrospective data from a tear film study (Kopf et al., J Optom. 2008;1:14-21) using basic high-speed videokeratoscopy, captured at 25 frames per see, were used. Eleven subjects underwent tear film analysis conducted in the morning, midday, and evening on the first and seventh day of I week of no lens wear. Five of the 11 subjects then completed an extra week of hydrogel lens wear, followed by a week of silicone hydrogel lens wear. Analysis was performed on a 6-sec period of the interblink recording. The dynamic-area high-speed videokeratoscopy technique uses the maximum available area of Placido ring pattern reflected from the tear interface and eliminates regions of disturbance because of shadows from the eyelashes. A value of tear film surface quality was derived using image-processing techniques based on the quality of the reflected ring pattern orientation. Results: ne group mean tear film surface quality and the standard deviations for each of the conditions (bare eye, hydrogel lens, and silicone hydrogel lens) showed a much lower coefficient of variation than that of previous methods (average reduction of approximately 92%). Bare eye measurements from the fight and left eyes of 11 individuals showed high correlation values (Pearson correlation r = 0.73 P<0.05). Repeated measures ANOVA across the 6-sec period of measurement in the normal interblink period for the bare eye condition showed no statistically significant changes. However, across the 6-sec interblink period with both the contact lenses, statistically significant changes were observed (P<0.001). Overall, wearing hydrogel and silicone hydrogel lenses caused the tear film surface quality to worsen compared with that of the bare eye condition (repeated measures ANOVA, P<0.0001 for both the hydrogel and silicone hydrogel). Conclusions: The results suggest that the dynamic-area method of highspeed videokeratoscopy was able to distinguish and quantify the subtle, but systematic worsening of tear film surface quality in the interblink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 31 条
[1]   Estimating Corneal Surface Topography in Videokeratoscopy in the Presence of Strong Signal Interference [J].
Alonso-Caneiro, David ;
Iskander, D. Robert ;
Collins, Michael J. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (10) :2381-2387
[2]   Assessment of Tear Film Surface Quality Using Dynamic-Area High-Speed Videokeratoscopy [J].
Alonso-Caneiro, David ;
Iskander, D. Robert ;
Collins, Michael J. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (05) :1473-1481
[3]  
ALONSOCANEIRO D, 2008, P IEEE INT WORKSH MU, V1, P486
[4]   Analysis of tear film breakup on Etafilcon A hydrogel lenses [J].
Bruce, AS ;
Mainstone, JC ;
Golding, TR .
BIOMATERIALS, 2001, 22 (24) :3249-3256
[5]   Ocular microfluctuations and videokeratoscopy [J].
Buehren, T ;
Lee, BJ ;
Collins, MJ ;
Iskander, DR .
CORNEA, 2002, 21 (04) :346-351
[6]   The stability of corneal topography in the post-blink interval [J].
Buehren, T ;
Collins, MJ ;
Iskander, DR ;
Davis, B ;
Lingelbach, B .
CORNEA, 2001, 20 (08) :826-833
[7]   AN INSTRUMENT FOR INVIVO TEAR FILM INTERFEROMETRY [J].
DOANE, MG .
OPTOMETRY AND VISION SCIENCE, 1989, 66 (06) :383-388
[8]  
Golding TR, 1997, CORNEA, V16, P649
[9]   A new method for tear film stability analysis using videokeratography [J].
Goto, T ;
Zheng, XD ;
Klyce, SD ;
Kataoka, H ;
Uno, T ;
Karon, M ;
Tatematsu, Y ;
Bessyo, T ;
Tsubota, K ;
Ohashi, Y .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (05) :607-612
[10]  
Guillon J P, 1998, Cont Lens Anterior Eye, V21 Suppl 1, pS31, DOI 10.1016/S1367-0484(98)80035-0