Differentiation of heavy metal ions by fluorescent quantum dot sensor array in complicated samples

被引:50
作者
Jiao, Zhe [1 ,2 ]
Zhang, Pengfei [3 ,4 ]
Chen, Hongwei [1 ,2 ]
Li, Cong [1 ]
Chen, Lina [1 ]
Fan, Hongbo [1 ,2 ]
Cheng, Faliang [1 ,2 ]
机构
[1] Dongguan Univ Technol, Sch Environm & Civil Engn, Dongguan, Peoples R China
[2] Dongguan Univ Technol, Guangdong Engn & Technol Res Ctr Adv Nanomat, Dongguan, Peoples R China
[3] Hong Kong Univ Sci & Technol, Div Biomed Engn, Clear Water Bay, Kowloon, Peoples R China
[4] Chinese Acad Sci, Shenzhen Inst Adv Technol, Inst Biomed & Biotechnol, Shenzhen, Peoples R China
关键词
Quantum dot; Senor array; Metal ions; PATTERN-RECOGNITION; DISCRIMINATION; PROTEINS; CELLS;
D O I
10.1016/j.snb.2019.05.059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The interference of co-existing substances often causes trouble in the analysis of trace metal ions in complex samples, even for highly selective sensors. For this reason, an instant and inexpensive fluorescence sensor array for discrimination of heavy metal ions in complex samples was developed. The sensor array was constructed using four kinds of Mn doped ZnS quantum dots (Mn: ZnS QDs), which were facilely modified with N-Acetyl-cysteine, citric acid, mercaptopropionic acid and triammonium-N-dithiocarboxyiminodiacetate, respectively. For each metal ion, quantitative calibration curves were obtained with the concentration level ranging from 10 to 100 pg/mL (R-2 > 0.96). Due to the different quenching effect for Cu, Hg, Ag and Cd on various QDs, the sensor array exhibited a unique pattern of fluorescence variations at a low concentration of 30 pg/ml and can be discriminated successfully by principal component analysis (PCA). The contribution of individual sensors within the array was demonstrated and the obtained information was used to design sensor arrays with two and three sensor elements. The sensor array was also applied to identify the metal ions in unknown mixtures, containing single, binary, ternary and quaternary constitutions. Linear discriminant analysis (LDA) showed that the samples could be well recognized and distinguished. The sensor array was finally applied in water samples with three different concentrations, indicating the co-existing substances rarely influenced discriminatory capacity of the sensor array. Compared to instrumental analysis, this fluorescence sensor array-based method has proven to be more convenient since the nanoparticles can be prepared flexibly according to the property of the target.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 25 条
[1]   Recent Trends in Macro-, Micro-, and Nanomaterial-Based Tools and Strategies for Heavy-Metal Detection [J].
Aragay, Gemma ;
Pons, Josefina ;
Merkoci, Arben .
CHEMICAL REVIEWS, 2011, 111 (05) :3433-3458
[2]   Heavy-metal ion sensor using chitosan capped ZnS quantum dots [J].
Borgohain, Rashi ;
Boruah, Prabin Kumar ;
Baruah, Sunandan .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 226 :534-539
[3]   Versatile immunosensor using CdTe quantum dots as electrochemical and fluorescent labels [J].
Cui, Rongjing ;
Pan, Hong-Cheng ;
Zhu, Jun-Jie ;
Chen, Hong-Yuan .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8494-8501
[4]   Nanometer-sized ceria-coated silica-iron oxide for the reagentless microextraction/preconcentration of heavy metals in environmental and biological samples followed by slurry introduction to ICP-OES [J].
Dados, A. ;
Paparizou, E. ;
Eleftheriou, P. ;
Papastephanou, C. ;
Stalikas, C. D. .
TALANTA, 2014, 121 :127-135
[5]  
Gulsu S., 2014, ACS APPL MATER INTER, V6, P18395
[6]   A cross-reactive sensor array for the fluorescence qualitative analysis of heavy metal ions [J].
Kang, Huaizhi ;
Lin, Liping ;
Rong, Mingcong ;
Chen, Xi .
TALANTA, 2014, 129 :296-302
[7]   RETRACTED: Mercaptoacetic acid capped CdS quantum dots as fluorescence single shot probe for mercury(II) (Retracted Article) [J].
Koneswaran, Masilamany ;
Narayanaswamy, Ramaier .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01) :91-96
[8]   RETRACTED: L-Cysteine-capped ZnS quantum dots based fluorescence sensor for Cu2+ ion (Retracted Article) [J].
Koneswaran, Masilamany ;
Narayanaswamy, Ramaier .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01) :104-109
[9]   A novel supramolecular metallogel-based high-resolution anion sensor array [J].
Lin, Qi ;
Lu, Tao-Tao ;
Zhu, Xin ;
Sun, Bin ;
Yang, Qing-Ping ;
Wei, Tai-Bao ;
Zhang, You-Ming .
CHEMICAL COMMUNICATIONS, 2015, 51 (09) :1635-1638
[10]   Exciton Energy Transfer-Based Quantum Dot Fluorescence Sensing Array: "Chemical Noses" for Discrimination of Different Nucleobases [J].
Liu, Jianbo ;
Li, Gui ;
Yang, Xiaohai ;
Wang, Kemin ;
Li, Li ;
Liu, Wei ;
Shi, Xing ;
Guo, Yali .
ANALYTICAL CHEMISTRY, 2015, 87 (02) :876-883