Next generation coronary CT angiography: in vitro evaluation of 27 coronary stents

被引:35
作者
Gassenmaier, Tobias [1 ]
Petri, Nils [2 ]
Allmendinger, Thomas [3 ]
Flohr, Thomas [3 ]
Maintz, David [4 ]
Voelker, Wolfram [2 ]
Bley, Thorsten A. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, D-97080 Wurzburg, Germany
[2] Univ Hosp Wurzburg, Dept Internal Med 1, Wurzburg, Germany
[3] Siemens Healthcare, Forchheim, Germany
[4] Univ Cologne, Dept Radiol, D-50931 Cologne, Germany
关键词
Multislice computed tomography; Coronary angiography; CT angiography; Stents; Artefacts; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DUAL-SOURCE CT; ARTERY STENTS; RESTENOSIS; PERFORMANCE; TRIAL;
D O I
10.1007/s00330-014-3323-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate in-stent lumen visibility of 27 modern and commonly used coronary stents (16 individual stent types, two stents at six different sizes each) utilising a third-generation dual-source CT system. Stents were implanted in a plastic tube filled with contrast. Examinations were performed parallel to the system's z-axis for all stents (i.e. 0A degrees) and in an orientation of 90A degrees for stents with a diameter of 3.0 mm. Two stents were evaluated in different diameters (2.25 to 4.0 mm). Examinations were acquired with a collimation of 96 x 0.6 mm, tube voltage of 120 kVp with 340 mAs tube current. Evaluation was performed using a medium-soft (Bv40), a medium-sharp (Bv49) and a sharp (Bv59) convolution kernel optimised for vascular imaging. Mean visible stent lumen of stents with 3.0 mm diameter ranged from 53.3 % (IQR 48.9 -aEuro parts per thousand 56.7 %) to 73.9 % (66.7 -aEuro parts per thousand 76.7 %), depending on the kernel used at 0A degrees, and was highest at an orientation of 90A degrees with 80.0 % (75.6 -aEuro parts per thousand 82.8 %) using the Bv59 kernel, strength 4. Visible stent lumen declined with decreasing stent size. Use of third-generation dual-source CT enables stent lumen visibility of up to 80 % in metal stents and 100 % in bioresorbable stents. aEuro cent Blooming artefacts impair in-stent lumen visibility of coronary stents in CT angiography. aEuro cent CT enables stent lumen visibility of up to 80 % in metal stents. aEuro cent Stent lumen visibility varies with stent orientation and size. aEuro cent CT angiography may be a valid alternative for detecting in-stent restenosis.
引用
收藏
页码:2953 / 2961
页数:9
相关论文
共 19 条
[1]  
Abbott Vascular, JOST GRAFTM HYDR COA
[2]   In-vitro assessment of coronary artery stents in 256-multislice computed tomography angiography [J].
André F. ;
Müller D. ;
Korosoglou G. ;
Hosch W. ;
Kauczor H.-U. ;
Katus H.A. ;
Steen H. .
BMC Research Notes, 7 (1)
[3]  
Boston Scientific, OMEGA PLAT CHROM COR
[4]  
Buuren F, 2010, KARDIOL, V4, P502
[5]   Diagnostic accuracy of 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: A meta-analysis [J].
Carrabba, Nazario ;
Schuijf, Joanne D. ;
de Graaf, Fleur R. ;
Parodi, Guido ;
Maffei, Erica ;
Valenti, Renato ;
Palumbo, Alessandro ;
Weustink, Annick C. ;
Mollet, Nico R. ;
Accetta, Gabriele ;
Cademartiri, Filippo ;
Antoniucci, David ;
Bax, Jeroen J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) :470-478
[6]   In-Stent Restenosis in the Drug-Eluting Stent Era [J].
Dangas, George D. ;
Claessen, Bimmer E. ;
Caixeta, Adriano ;
Sanidas, Elias A. ;
Mintz, Gary S. ;
Mehran, Roxana .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (23) :1897-1907
[7]   High-Pitch 128-Slice Dual-Source CT for the Assessment of Coronary Stents in a Phantom Model [J].
Donati, Olivio F. ;
Burg, Matthias C. ;
Desbiolles, Lotus ;
Karlo, Christoph ;
Stolzmann, Paul ;
Bunck, Alexander ;
Baumueller, Stephan ;
Marincek, Borut ;
Seifarth, Harald ;
Alkadhi, Hatem ;
Leschka, Sebastian ;
Maintz, David .
ACADEMIC RADIOLOGY, 2010, 17 (11) :1366-1374
[8]   Multislice spiral computed tomography for the detection of coronary stent restenosis and patency [J].
Krüger, S ;
Mahnken, AH ;
Sinha, AM ;
Borghans, A ;
Dedden, K ;
Hoffmann, R ;
Hanrath, P .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 89 (2-3) :167-172
[9]   64-slice multidetector coronary CT angiography:: in vitro evaluation of 68 different stents [J].
Maintz, D ;
Seifarth, H ;
Raupach, R ;
Flohr, T ;
Rink, M ;
Sommer, T ;
Özgün, M ;
Heindel, W ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2006, 16 (04) :818-826
[10]   Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT [J].
Maintz, David ;
Burg, Matthias C. ;
Seifarth, Harald ;
Bunck, Alexander C. ;
Oezguen, Murat ;
Fischbach, Roman ;
Juergens, Kai Uwe ;
Heindel, Walter .
EUROPEAN RADIOLOGY, 2009, 19 (01) :42-49