Integrating organic micropollutant removal into tertiary filtration: Combining PAC adsorption with advanced phosphorus removal

被引:65
作者
Altmann, Johannes [1 ]
Sperlich, Alexander [2 ]
Jekel, Martin [1 ]
机构
[1] Tech Univ Berlin, Chair Water Qual Control, D-10623 Berlin, Germany
[2] Berliner Wasserbetriebe, D-10709 Berlin, Germany
关键词
Organic micropollutants; Powdered activated carbon (PAC); Adsorption; Deep-bed filtration; Wastewater treatment; POWDERED ACTIVATED CARBON; WASTE-WATER; AQUATIC ENVIRONMENT; CONTAMINANTS; OZONE;
D O I
10.1016/j.watres.2015.07.023
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Direct addition of powdered activated carbon (PAC) to a deep-bed filter was investigated at pilot-scale as a single advanced treatment stage for simultaneous removal of organic micropollutants (OMPs) and phosphorus from secondary effluent. PAC doses of 10-50 mg/L were assessed with regard to their impacts on filter performance and removal of 15 selected OMPs over a period of 18 months. The PAC was effectively retained by the filter and had no negative effect on filter head loss. Filter runtime until particle breakthrough depended mainly on coagulant dose and did not decrease significantly due to the additional PAC load. Removal of suspended solids and phosphorus by coagulation was effective independent of the PAC dose. A PAC dose of 35 mg/L PAC was suitable to remove well-adsorbing OMPs (e.g. carbamazepine, diclofenac) by >80% and medium adsorbing OMPs (e.g. primidone, sulfamethoxazole) by 50 -80%. Median removals were 50-80% for well-adsorbing and 30-50% for medium adsorbing OMPs with 20 mg/L PAC. Abatement of all OMPs was low (<50%) with 10 mg/L PAC, possibly because of the high effluent organic matter content (median dissolved organic carbon (DOC) concentrations of 11.2 mg/L). In addition to adsorptive removal, relevant concentration decreases of certain OMPs (e.g. 4-formylaminoantipyrine) were attributed to biological transformation in the filter. Adsorption onto accumulating PAC in the top layer of the filter bed led to improved OMP adsorption with increasing filter runtime. The comparison of OMP removal in the pilot filter with laboratory adsorption tests demonstrates that batch test results can be applied to estimate adsorptive OMP removal in real applications. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:58 / 65
页数:8
相关论文
共 25 条
[1]   How to dose powdered activated carbon in deep bed filtration for efficient micropollutant removal [J].
Altmann, Johannes ;
Ruhl, Aki S. ;
Sauter, Daniel ;
Pohl, Julia ;
Jekel, Martin .
WATER RESEARCH, 2015, 78 :9-17
[2]   Direct comparison of ozonation and adsorption onto powdered activated carbon for micropollutant removal in advanced wastewater treatment [J].
Altmann, Johannes ;
Ruhl, Aki Sebastian ;
Zietzschmann, Frederik ;
Jekel, Martin .
WATER RESEARCH, 2014, 55 :185-193
[3]   Removal of micropollutants in municipal wastewater treatment plants by powder-activated carbon [J].
Boehler, M. ;
Zwickenpflug, B. ;
Hollender, J. ;
Ternes, T. ;
Joss, A. ;
Siegrist, H. .
WATER SCIENCE AND TECHNOLOGY, 2012, 66 (10) :2115-2121
[4]  
DWA, 2011, ARB DWA A 202 CHEM P
[5]   Reducing the Discharge of Micropollutants in the Aquatic Environment: The Benefits of Upgrading Wastewater Treatment Plants [J].
Eggen, Rik I. L. ;
Hollender, Juliane ;
Joss, Adriano ;
Schaerer, Michael ;
Stamm, Christian .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (14) :7683-7689
[6]   Elimination of Organic Micropollutants in a Municipal Wastewater Treatment Plant Upgraded with a Full-Scale Post-Ozonation Followed by Sand Filtration [J].
Hollender, Juliane ;
Zimmermann, Saskie G. ;
Koepke, Stephan ;
Krauss, Martin ;
McArdell, Christa S. ;
Ort, Christoph ;
Singer, Heinz ;
von Gunten, Urs ;
Siegrist, Hansruedi .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (20) :7862-7869
[7]   Full- and pilot-scale GAC adsorption of organic micropollutants [J].
Kennedy, Anthony M. ;
Reinert, Allison M. ;
Knappe, Detlef R. U. ;
Ferrer, Imma ;
Summers, R. Scott .
WATER RESEARCH, 2015, 68 :238-248
[8]   Elimination of Micropollutants during Post-Treatment of Hospital Wastewater with Powdered Activated Carbon, Ozone, and UV [J].
Kovalova, Lubomira ;
Siegrist, Hansruedi ;
von Gunten, Urs ;
Eugster, Jakob ;
Hagenbuch, Martina ;
Wittmer, Anita ;
Moser, Ruedi ;
McArdell, Christa S. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (14) :7899-7908
[9]   Assessment of the application of bioanalytical tools as surrogate measure of chemical contaminants in recycled water [J].
Leusch, Frederic D. L. ;
Khan, Stuart J. ;
Laingam, Somprasong ;
Prochazka, Erik ;
Froscio, Suzanne ;
Trang Trinh ;
Chapman, Heather F. ;
Humpage, Andrew .
WATER RESEARCH, 2014, 49 :300-315
[10]   Endocrine disrupting effects of benzotriazole in rare minnow (Gobiocypris rarus) in a sex-dependent manner [J].
Liang, Xuefang ;
Wang, Miao ;
Chen, Xi ;
Zha, Jinmiao ;
Chen, Huihui ;
Zhu, Lifei ;
Wang, Zijian .
CHEMOSPHERE, 2014, 112 :154-162