Dispersive solid-phase microextraction method for sample extraction in the analysis of four tetracyclines in water and milk samples by high-performance liquid chromatography with diode-array detection

被引:175
作者
Tsai, Wen-Hsien [2 ]
Huang, Tzou-Chi [2 ]
Huang, Joh-Jong [3 ]
Hsue, Yi-Huu [3 ]
Chuang, Hung-Yi [1 ,4 ]
机构
[1] Kaohsiung Med Univ, Sch Publ Hlth, Kaohsiung 807, Taiwan
[2] Natl Pingtung Univ Sci & Technol, Dept Food Sci, Pingtung 912, Taiwan
[3] Hlth Bur Kaohsiung Cty Govt, Kaohsiung 833, Taiwan
[4] Kaohsiung Med Univ, Dept Community Med, Kaohsiung 807, Taiwan
关键词
Dispersive solid-phase microextraction; Sample preparation; Milk analysis; Water analysis; Tetracyclines; TANDEM MASS-SPECTROMETRY; CHELATE AFFINITY-CHROMATOGRAPHY; PESTICIDE-RESIDUE ANALYSIS; ANIMAL-TISSUES; SORPTIVE EXTRACTION; GAS-CHROMATOGRAPHY; TRACE ANALYSIS; WASTE-WATER; ANTIBIOTICS; SULFONAMIDES;
D O I
10.1016/j.chroma.2009.01.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A dispersive solid-phase microextraction (dispersive-SPME) method for the determination of tetracycline, oxytetracycline,chlortetracycline and doxycycline is proposed. Different silica-based and polymeric sorbents were evaluated for their capacity to simultaneously preconcentrate tetracyclines (TCs) in the dispersive format from aqueous or organic solutions. Silica-based sorbents especially functionalized with primary amine, secondary amine, or carbonyl groups have showed higher capacity than polymeric sorbents under organic environment. In the proposed dispersive solid-phase microextraction method, after extraction with acetonitrile and salt-promoted partitioning, TCs were adsorbed to a small amount of dispersive silica-based primary and secondary amine sorbents, desorbed with a small volume of desorption solution, and determined by high-performance liquid chromatography with diode-array detection. Under the optimal conditions, recoveries were determined for surface water and milk samples spiked at 10 ng/mL and 50-150 ng/g, respectively, and quantification was achieved by matrix-matched calibration. The calibration curves of four TCs in both samples showed linearity with a correlation coefficient value above 0.997. Average recoveries ranged from 97.1 to 104.1% and the precision was from 2.0 to 5.6%. Limits of detection ranged from 0.7 to 3.5 ng/mL and from 7.9 to 35.3 ng/g for four TCs Surface in Surface water and milk samples, respectively. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2263 / 2269
页数:7
相关论文
共 35 条
[1]   Multi-residue determination of veterinary drugs in milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry [J].
Aguilera-Luiz, M. M. ;
Martinez Vidal, Jose Luis ;
Romero-Gonzalez, Roberto ;
Garrido Frenich, Antonia .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1205 (1-2) :10-16
[2]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[3]   Complexities in tetracycline analysis - chemistry, matrix extraction, cleanup, and liquid chromatography [J].
Anderson, CR ;
Rupp, HS ;
Wu, WH .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :23-32
[4]  
[Anonymous], TRENDS ANAL CHEM
[5]   Simultaneous determination of sulfonamides, tetracyclines and tiamulin in swine wastewater by solid-phase extraction and liquid chromatography-mass spectrometry [J].
Ben, Weiwei ;
Qiang, Zhimin ;
Adams, Craig ;
Zhang, Heqing ;
Chen, Liping .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (02) :173-180
[6]   Restricted access materials for sample clean-up in the analysis of trace levels of tetracyclines by liquid chromatography Application to food and environmental analysis [J].
Chico, J. ;
Meca, S. ;
Companyo, R. ;
Prat, M. D. ;
Granados, M. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1181 (1-2) :1-8
[7]   Use of metal chelate affinity chromatography and membrane-based ion-exchange as clean-up procedure for trace residue analysis of tetracyclines in animal tissues and egg [J].
Croubels, SM ;
Vanoosthuyze, KEI ;
VanPeteghem, CH .
JOURNAL OF CHROMATOGRAPHY B, 1997, 690 (1-2) :173-179
[8]   Stir bar sorptive extraction for trace analysis [J].
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :54-69
[9]   Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography [J].
Eisert, R ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3140-3147
[10]   Confirmatory and quantitative analysis of β-lactam antibiotics in bovine kidney tissue by dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry [J].
Fagerquist, CK ;
Lightfield, AR ;
Lehotay, SJ .
ANALYTICAL CHEMISTRY, 2005, 77 (05) :1473-1482