Sliding mode control for performance improvement of shunt active power filter

被引:7
作者
Ullah, Ikram [1 ]
Ashraf, Muhammad [1 ]
机构
[1] CUST, Dept Elect Engn, Islamabad, Pakistan
来源
SN APPLIED SCIENCES | 2019年 / 1卷 / 06期
关键词
Harmonics mitigation; Shunt active power filter; Power quality improvement; CONTROL STRATEGY;
D O I
10.1007/s42452-019-0554-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The increased use of non-linear loads results in more harmonics content in the source current. Shunt active power filters are used for correction of distorted source current by injecting a compensating current in parallel to the load current. The injected current will shape the supply current to a sinusoidal. In this paper an improved performance of shunt active power filter is achieved by using sliding mode controller for generation of gate pulses of voltage source inverter. The implemented control technique has been evaluated and compared with hysteresis current control. The performance parameters used for evaluating the shunt active power filter are total harmonic distortion, power factor and harmonics compensation ratio. The simulation results show excellent performance of active power filter in terms of harmonics mitigation and dynamic response. Experimental tests are also performed using NI DAQ card in Labview environment to validate the simulation results. Both the simulation and experimental results prove good performance of sliding mode control for accurate injection of reference current.
引用
收藏
页数:10
相关论文
共 35 条
[1]  
Abdikarimuly R, 2016, 2016 IEEE INT POW EL
[2]   Improved Active Power Filter Performance for Renewable Power Generation Systems [J].
Acuna, Pablo ;
Moran, Luis ;
Rivera, Marco ;
Dixon, Juan ;
Rodriguez, Jose .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (02) :687-694
[3]  
Adam G, 2012, 2012 INT C EXP EL PO
[4]   Comparative Performance of Wiener Filter and Adaptive Least Mean Square-Based Control for Power Quality Improvement [J].
Badoni, Manoj ;
Singh, Alka ;
Singh, Bhim .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (05) :3028-3037
[5]  
Bandal VS, 2012, 2012 IEEE 12 INT WOR
[6]  
Bento AA, 2017, 2017 IEEE SO POW EL
[7]  
Bhople SU, 2016, INT J CURR ENG TECHN
[8]   Adaptive Fractional Fuzzy Sliding Mode Control for Three-Phase Active Power Filter [J].
Cao, Di ;
Fei, Juntao .
IEEE ACCESS, 2016, 4 :6645-6651
[9]   Analysis, design and digital implementation of a shunt active power filter with different schemes of reference current generation [J].
Chauhan, Siddharthsingh K. ;
Shah, Mihir C. ;
Tiwari, Ram Ratan ;
Tekwani, P. N. .
IET POWER ELECTRONICS, 2014, 7 (03) :627-639
[10]   Analysis of DC-Link Voltage Controls in Three-Phase Four-Wire Hybrid Active Power Filters [J].
Choi, Wai-Hei ;
Lam, Chi-Seng ;
Wong, Man-Chung ;
Han, Ying-Duo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (05) :2180-2191