A europium- and terbium-coated magnetic nanocomposite as sorbent in dispersive solid phase extraction coupled with ultra-high performance liquid chromatography for antibiotic determination in meat samples

被引:40
作者
Castillo-Garcia, M. L. [1 ]
Aguilar-Caballos, M. P. [1 ]
Gomez-Hens, A. [1 ]
机构
[1] Univ Cordoba, Fac Sci, Inst Fine Chem & Nanochem, Dept Analyt Chem, Cordoba 14071, Spain
关键词
Quinolones; Tetracyclines; Eu- and Tb-coated magnetic nanoparticles; Ultra-performance liquid chromatography; Fluorometric detection; Meat samples; MASS-SPECTROMETRY; POSTCOLUMN DERIVATIZATION; ENVIRONMENTAL WATER; MULTICLASS METHOD; RESIDUE ANALYSIS; MILK SAMPLES; FLUOROQUINOLONES; QUINOLONES; SEPARATION; MUSCLE;
D O I
10.1016/j.chroma.2015.11.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new magnetic dispersive solid-phase extraction approach based on Eu- and Tb-coated magnetic nanocomposites, combined with ultra-high performance liquid chromatography with fluorometric detection, is reported for the extraction and simultaneous determination of veterinary antibiotics. The method is aimed at monitoring of potential residues of three tetracyclines, namely oxytetracycline, tetracycline, chlortetracycline and three acidic quinolones, such as oxolinic acid, nalidixic acid and flumequine, chosen as model analytes, in animal muscle samples. The nanocomposites were obtained by synthesizing magnetic nanoparticles by a co-precipitation method and their coating with terbium and europium ions. The limits of detection obtained using standard solutions were: 1.0, 1.5, 3.8, 0.25, 0.7 and 1.2 ng mL(-1), which corresponds to 3.3, 5.0, 12.7, 0.8, 2.3 and 4.0.mu g kg(-1) for oxytetracycline, tetracycline, chlortetracycline, oxolinic acid, nalidixic acid and flumequine, respectively, in meat samples. The precision values, obtained in the presence of the sample matrix, were in the ranges 0.12-2.0% and 2.6-15.4% for retention times and areas, respectively. The selectivity of the method was checked by assaying different veterinary drugs, finding that most of them did not interfere at the same concentration levels as that of analytes. A recovery study was performed in the presence of chicken and pork muscle samples, which provided values in the range of 61.5-102.6%. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 32 条
[1]   Development of an automatic high-throughput assay for tetracycline determination by using Eu2O3 nanoparticles and dry-reagent technology [J].
Aguilar-Vazquez, L. ;
Aguilar-Caballos, M. P. ;
Gomez-Hens, A. .
TALANTA, 2014, 119 :111-115
[2]   Complexities in tetracycline analysis - chemistry, matrix extraction, cleanup, and liquid chromatography [J].
Anderson, CR ;
Rupp, HS ;
Wu, WH .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :23-32
[3]  
[Anonymous], 2010, DECALAGES
[4]  
[Anonymous], 2002, OFF J EUR UNION L, VL125, P10
[5]   A high-throughput method for the determination of quinolones in different matrices by ultra-high performance liquid chromatography with fluorescence detection [J].
Arroyo-Manzanares, Natalia ;
Huertas-Perez, Jose F. ;
Lombardo-Aguei, Manuel ;
Gamiz-Gracia, Laura ;
Garcia-Campana, Ana M. .
ANALYTICAL METHODS, 2015, 7 (01) :253-259
[6]   Determination of pKa values of active pharmaceutical ingredients [J].
Babic, Sandra ;
Horvat, Alka J. M. ;
Pavlovic, Dragana Mutavdzic ;
Kastelan-Macan, Marija .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (11) :1043-1061
[7]   Comparison of three solid-phase extraction processes in quantification of ciprofloxacin and enrofloxacin in pork meat [J].
Blesa, Jesus ;
Silva, Liliana J. G. ;
Lino, Celeste M. ;
Font, Guillermina ;
Pena, Angelina .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (07) :832-838
[8]   Multi-residue analysis of pharmaceuticals in aqueous environmental samples by online solid-phase extraction-ultra-high-performance liquid chromatography-tandem mass spectrometry: Optimisation and matrix effects reduction by quick, easy, cheap, effective, rugged and safe extraction [J].
Bourdat-Deschamps, Marjolaine ;
Leang, Sokha ;
Bernet, Nathalie ;
Daudin, Jean-Jacques ;
Nelieu, Sylvie .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1349 :11-23
[9]   Multi-residue and multi-class method for the determination of antibiotics in bovine muscle by ultra-high-performance liquid chromatography tandem mass spectrometry [J].
Freitas, Andreia ;
Barbosa, Jorge ;
Ramos, Fernando .
MEAT SCIENCE, 2014, 98 (01) :58-64
[10]   Optimization of a phase separation based magnetic-stirring salt-induced liquid-liquid microextraction method for determination of fluoroquinolones in food [J].
Gao, Ming ;
Wang, Huili ;
Ma, Meiping ;
Zhang, Yuna ;
Yin, Xiaohan ;
Dahlgren, Randy A. ;
Du, Dongli ;
Wang, Xuedong .
FOOD CHEMISTRY, 2015, 175 :181-188