Real-time radio-transparent dosimeter for X-ray imaging system

被引:4
作者
Staub, D [1 ]
Cailleret, J [1 ]
Guyonnet, JL [1 ]
Le, TD [1 ]
Wurtz, J [1 ]
机构
[1] Univ Strasbourg 1, CNRS, IN2P3, IReS Inst Rech Subatom, F-67037 Strasbourg 2, France
关键词
X-ray imaging; dosimetry; real time; transparent dosimeter; scintillating fibers; multianode PMT;
D O I
10.1016/j.nima.2004.03.078
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Possible consequences of using X-ray devices as imaging support during surgical practices may be the development of skin diseases due to the combination of high local dose and long exposition time. Our group developed an original dosimeter which meets the following requirements: transparency to X-ray to avoid image degradation, measurement and localization in real-time of the dose absorbed by the skin on the whole exposed surface. The main purpose of this dosimeter is to allow the practitioner to change the beam orientation during the intervention in order to reduce the local dose and then avoid, in the extreme cases, the development of tumors. The dosimeter is composed of a lattice of scintillator fibers connected to a 64 channels photomultiplier tube. The detector combined with an appropriate electronics provides in real time an accurate measurement of the dose on the whole exposed surface. A linear relation between the photon count rate and the dose is demonstrated. Our dosimeter provides also in real time a map of the dose which leads to a very efficient monitoring of the dose during all the exposition time. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:303 / 307
页数:5
相关论文
共 50 条
  • [1] Optical Microscanning X-ray Real-time Imaging System
    Gao Meijing
    Wu Weilong
    Xu Wei
    Wang Jingyuan
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, ELECTRONIC, INDUSTRIAL AND CONTROL ENGINEERING, 2014, 5 : 1136 - 1140
  • [2] Real-time X-ray imaging data acquisition system for pnCCD
    Huo, Jia
    Zhao, Xiaofan
    Cui, Weiwei
    Wang, Yusa
    Wang, Hao
    Chen, Yong
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2024, 32 (21): : 3166 - 3173
  • [3] Flat X-ray image intensifier system for real-time fluoroscopy
    Onihashi, H
    Aida, H
    Nou, K
    Noji, T
    Murakoshi, Y
    Saito, K
    Koma, J
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 145 - 150
  • [4] A CdTe real time X-ray imaging sensor and system
    Spartiotis, K
    Havulinna, J
    Leppänen, A
    Pantsar, T
    Puhakka, K
    Pyyhtiä, J
    Schulman, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (03) : 478 - 486
  • [5] Real-time wavelet denoising with edge enhancement for medical x-ray imaging
    Luo, Gaoyong
    Osypiw, David
    Hudson, Chris
    REAL-TIME IMAGE PROCESSING 2006, 2006, 6063
  • [6] Improving the dynamic range of real-time X-ray imaging systems via bayesian fusion
    Anne Dromigny
    Yue Min Zhu
    Journal of Nondestructive Evaluation, 1997, 16 : 147 - 160
  • [7] Real-time guidewire tracking and segmentation in intraoperative X-ray
    Zhang, Baochang
    Bui, Mai
    Wang, Cheng
    Bourier, Felix
    Schunkert, Heribert
    Navab, Nassir
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [8] Improving the Dynamic Range of Real-Time X-Ray Imaging Systems via Bayesian Fusion
    Anne Dromigny
    Yue Min Zhu
    Journal of Nondestructive Evaluation, 1997, 16 (3) : 147 - 160
  • [9] Improving the dynamic range of real-time X-ray imaging systems via Bayesian fusion
    Dromigny, A
    Zhu, YM
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 1997, 16 (03) : 147 - 160
  • [10] Real-Time Optical Fiber Dosimeter Probe
    Croteau, Andre
    Caron, Serge
    Rink, Alexandra
    Jaffray, David
    Mermut, Ozzy
    OPTICAL FIBERS, SENSORS, AND DEVICES FOR BIOMEDICAL DIAGNOSTICS AND TREATMENT XI, 2011, 7894