Electrical impedance tomography for non-invasive assessment of stroke volume variation in health and experimental lung injury

被引:13
作者
Trepte, C. J. C. [1 ]
Phillips, C. [2 ]
Sola, J. [3 ]
Adler, A. [4 ]
Saugel, B. [1 ]
Haas, S. [1 ]
Bohm, S. H. [5 ]
Reuter, D. A. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Anaesthesiol, Ctr Anaesthesiol & Intens Care Med, Martinistr 52, D-20246 Hamburg, Germany
[2] Oregon Hlth & Sci Univ, Dept Pulm & Crit Care, Portland, OR 97201 USA
[3] Ctr Suisse Elect & Microtech, Neuchatel, Switzerland
[4] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON, Canada
[5] Swisstom AG, Landquart, Switzerland
关键词
electrical impedance; methods; monitoring; physiologic; physiology; positive-pressure respiration; stroke volume; PULSE PRESSURE VARIATION; FLUID RESPONSIVENESS; OLEIC-ACID; IMPROVES OXYGENATION; ANIMAL-MODELS; PRELOAD; THERMODILUTION; SURGERY; LAVAGE; ICU;
D O I
10.1093/bja/aew341
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Functional imaging by thoracic electrical impedance tomography (EIT) is a non-invasive approach to continuously assess central stroke volume variation (SVV) for guiding fluid therapy. The early available data were from healthy lungs without injury-related changes in thoracic impedance as a potentially influencing factor. The aim of this study was to evaluate SVV measured by EIT (SVVEIT) against SVV from pulse contour analysis (SVVPC) in an experimental animal model of acute lung injury at different lung volumes. Methods. We conducted a randomized controlled trial in 30 anaesthetized domestic pigs. SVVEIT was calculated automatically analysing heart-lung interactions in a set of pixels representing the aorta. Each initial analysis was performed automatically and unsupervised using predefined frequency domain algorithms that had not previously been used in the study population. After baseline measurements in normal lung conditions, lung injury was induced either by repeated bronchoalveolar lavage (n = 15) or by intravenous administration of oleic acid (n = 15) and SVVEIT was remeasured. Results. The protocol was completed in 28 animals. A total of 123 pairs of SVV measurements were acquired. Correlation coefficients (r) between SVVEIT and SVVPC were 0.77 in healthy lungs, 0.84 after broncho-alveolar lavage, and 0.48 after lung injury from oleic acid. Conclusions. EIT provides automated calculation of a dynamic preload index of fluid responsiveness (SVVEIT) that is non-invasively derived from a central haemodynamic signal. However, alterations in thoracic impedance induced by lung injury influence this method.
引用
收藏
页码:68 / 76
页数:9
相关论文
共 46 条
  • [1] PATHOGENESIS OF OLEIC ACID-INDUCED LUNG INJURY IN THE RAT - DISTRIBUTION OF OLEIC-ACID DURING INJURY AND EARLY ENDOTHELIAL-CELL CHANGES
    BEILMAN, G
    [J]. LIPIDS, 1995, 30 (09) : 817 - 823
  • [2] Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study
    Benes, Jan
    Chytra, Ivan
    Altmann, Pavel
    Hluchy, Marek
    Kasal, Eduard
    Svitak, Roman
    Pradl, Richard
    Stepan, Martin
    [J]. CRITICAL CARE, 2010, 14 (03):
  • [3] Detection of 'best' positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial
    Blankman, Paul
    Hasan, Djo
    Erik, Groot Jebbink
    Gommers, Diederik
    [J]. CRITICAL CARE, 2014, 18 (03):
  • [4] Early Inflammation Mainly Affects Normally and Poorly Aerated Lung in Experimental Ventilator-Induced Lung Injury*
    Borges, Joao Batista
    Costa, Eduardo L. V.
    Suarez-Sipmann, Fernando
    Widstrom, Charles
    Larsson, Anders
    Amato, Marcelo
    Hedenstierna, Goran
    [J]. CRITICAL CARE MEDICINE, 2014, 42 (04) : E279 - E287
  • [5] The increase of vasomotor tone avoids the ability of the dynamic preload indicators to estimate fluid responsiveness
    Bouchacourt, Juan P.
    Riva, Juan A.
    Grignola, Juan C.
    [J]. BMC ANESTHESIOLOGY, 2013, 13
  • [6] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [7] Heart-lung interactions with different ventilatory settings during acute lung injury and hypovolaemia: an experimental study
    da Silva Ramos, F. J.
    de Oliveira, E. M.
    Park, M.
    Schettino, G. P. P.
    Azevedo, L. C. P.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (03) : 394 - 402
  • [8] Dewitte K, 2002, CLIN CHEM, V48, P799
  • [9] Arterial Lines in the ICU A Call for Rigorous Controlled Trials
    Garland, Allan
    [J]. CHEST, 2014, 146 (05) : 1155 - 1158
  • [10] Individually Optimized Hemodynamic Therapy Reduces Complications and Length of Stay in the Intensive Care Unit A Prospective, Randomized Controlled Trial
    Goepfert, Matthias S.
    Richter, Hans Peter
    Eulenburg, Christine Zu
    Gruetzmacher, Janna
    Rafflenbeul, Erik
    Roeher, Katharina
    von Sandersleben, Alexandra
    Diedrichs, Stefan
    Reichenspurner, Herrmann
    Goetz, Alwin E.
    Reuter, Daniel A.
    [J]. ANESTHESIOLOGY, 2013, 119 (04) : 824 - 836