Innovative strategies for enhancing fire performance of high-strength concrete structures

被引:30
作者
Kodur, Venkatesh K. R. [1 ]
机构
[1] Michigan State Univ, Dept Civil & Environm Engn, E Lansing, MI 48824 USA
关键词
fire resistance; governing factors; high-strength concrete; innovative strategies; reinforced concrete columns; spalling; COLUMNS; RESISTANCE; ENDURANCE;
D O I
10.1177/1369433218754335
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-strength concrete is being increasingly used in a number of building applications, where structural fire safety is one of the primary design considerations. Many research studies clearly indicate that the fire performance of high-strength concrete is different from that of normal-strength concrete and that high-strength concrete may not exhibit same level of performance as normal-strength concrete under fire conditions. This article outlines key characteristics that influence the performance of high-strength concrete structural members under fire conditions. Data generated in previous experimental and numerical studies are utilized to illustrate various factors that influence fire performance of high-strength concrete structural members. Based on the published data, observations and trends on the behavior of high-strength concrete members, innovative strategies for mitigating spalling and enhancing fire resistance of high-strength concrete structural members are proposed.
引用
收藏
页码:1723 / 1732
页数:10
相关论文
共 26 条
[1]   Outcomes of a major research on fire resistance of concrete columns [J].
Ali, F ;
Nadjai, A ;
Silcock, G ;
Abu-Tair, A .
FIRE SAFETY JOURNAL, 2004, 39 (06) :433-445
[2]   Explosive spalling of high-strength concrete columns in fire [J].
Ali, FA ;
O'Connor, D ;
Abu-Tair, A .
MAGAZINE OF CONCRETE RESEARCH, 2001, 53 (03) :197-204
[3]  
[Anonymous], 2016, SFPE HDB FIRE PROTEC
[4]  
[Anonymous], 2014, 114201 ACI
[5]  
[Anonymous], 2004, 1992122004 EN
[6]   Optimization of the type and amount of polypropylene fibres for preventing the spalling of lightweight concrete subjected to hydrocarbon fire [J].
Bilodeau, A ;
Kodur, VKR ;
Hoff, GC .
CEMENT & CONCRETE COMPOSITES, 2004, 26 (02) :163-174
[7]  
Danielsen U, 1997, 5676 SINTEF NORW FIR
[8]  
Diederichs U., 1995, P 4 WEIMAR WORKSHOP, P219
[9]  
George SJ, 2012, INT J CONCR STRUCT M, V6, P111
[10]   Limits of spalling of fire-exposed concrete [J].
Hertz, KD .