Temperature Evaluation During PMMA Screw Augmentation in Osteoporotic Bone-An In Vitro Study About the Risk of Thermal Necrosis in Human Femoral Heads

被引:63
作者
Boner, Vanessa [1 ]
Kuhn, Philipp [1 ]
Mendel, Thomas [1 ,2 ]
Gisep, Armando [1 ]
机构
[1] AO Dev Inst, Davos, Switzerland
[2] BG Kliniken Bergmannstrost, Klin Unfall & Wiederherstellungschirurg, Halle, Saale, Germany
关键词
osteoporosis; PMMA augmentation; exothermic reaction; thermal necrosis; JOINT REPLACEMENT; INTERNAL-FIXATION; CEMENT; POLYMERIZATION; FRACTURES; POLYMETHYLMETHACRYLATE; INTERFACE; NECK;
D O I
10.1002/jbm.b.31353
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of polymethylmethacrylate (PMMA) bone cement to augment hip screws reduces cut-out risk but is associated with an exothermic reaction. This in vitro investigation evaluated the risk of thermal necrosis when augmenting the implant purchase with PMMA. A pilot study analyzed the effects of different PMMA layer thicknesses on temperatures around an implant. The main study used either 3.0 or 6.0 cc PMMA for hip screw augmentation in human femoral heads. The risk of thermal necrosis was estimated according to critical values reported in literature. Highest temperatures were measured inside the PMMA with a significant drop of average maximum temperatures from the center of the PMMA to the PMMA/bone interface. Risk of thermal necrosis exists with PMMA layer thicknesses greater than 5.0 mm. In the main study, we found no risk of thermal necrosis at the PMMA/bone interface or in the surrounding bone, neither with 3.0 nor 6.0 cc PMMA. The results of the two studies were consistent regarding average peak temperatures related to associated cement layer thicknesses. The results of this in vitro study reduce objections concerning the risk of thermal necrosis when augmenting cancellous bone around hip screws with up to 6.0 cc PMMA. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 90B: 842-848, 2009
引用
收藏
页码:842 / 848
页数:7
相关论文
共 27 条
[1]  
ANDERSEN E, 1989, CLIN ORTHOP RELAT R, P200
[2]   Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty [J].
Belkoff, SM ;
Molloy, S .
SPINE, 2003, 28 (14) :1555-1559
[3]   EXPERIMENTAL RESEARCH ON HEAT-DEVELOPMENT IN BONE DURING POLYMERIZATION OF BONE CEMENT [J].
BIEHL, G ;
HANSER, U ;
HARMS, J .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1974, 78 (01) :62-69
[4]   Isothermal and non-isothermal polymerization of a new bone cement [J].
Borzacchiello, A ;
Ambrosio, L ;
Nicolais, L ;
Harper, EJ ;
Tanner, KE ;
Bonfield, W .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (06) :317-324
[5]   REDUCTION OF TEMPERATURES GENERATED BY THE TRIPLE REAMER WITHIN THE FEMORAL-HEAD [J].
CALDER, SJ ;
BARNES, MR ;
HARPER, WM .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (03) :183-185
[6]   INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31
[7]   Temperature elevation caused by bone cement polymerization during vertebroplasty [J].
Deramond, H ;
Wright, NT ;
Belkoff, SM .
BONE, 1999, 25 (02) :17S-21S
[8]   THE EFFECT OF CIRCULATION ON THE POLYMERIZING TEMPERATURE OF PALACOS - AN EXPERIMENTAL-STUDY [J].
EITENMULLER, J ;
WOLBERT, R ;
EISEN, E .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1981, 98 (01) :61-67
[9]   TEMPERATURE THRESHOLD LEVELS FOR HEAT-INDUCED BONE TISSUE-INJURY - A VITAL-MICROSCOPIC STUDY IN THE RABBIT [J].
ERIKSSON, AR ;
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (01) :101-107
[10]  
Fukushima Hisanori, 2002, Kobe Journal of Medical Sciences, V48, P63