Precision Medicine in Ossiculoplasty

被引:9
作者
Mukherjee, Payal [1 ]
Cheng, Kai [1 ]
Chung, Johnson [2 ]
Grieve, Stuart M. [3 ,4 ]
Solomon, Michael [1 ,5 ,6 ]
Wallace, Gordon [2 ]
机构
[1] Royal Prince Alfred Hosp, RPA Inst Acad Surg, Sydney, NSW, Australia
[2] Univ Wollongong, Intelligent Polymer Res Inst, ARC Ctr Excellence Electromat Sci, Wollongong, NSW, Australia
[3] Royal Prince Alfred Hosp, Dept Radiol, Sydney, NSW, Australia
[4] Univ Sydney, Fac Med & Hlth, Charles Perkins Ctr, Imaging & Phenotyping Lab, Sydney, NSW 2006, Australia
[5] Royal Prince Alfred Hosp, Surg Outcomes Res Ctr SOuRCe, Sydney, NSW, Australia
[6] Royal Prince Alfred Hosp, Dept Colorectal Surg, Sydney, NSW, Australia
关键词
3D analysis; 3D printing; Bioprinting; Conebeam CT; CT; microCT; Ossiculoplasty; Precision medicine;
D O I
10.1097/MAO.0000000000002928
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction: Long term results of ossiculoplasty surgery are considered poor with displacement and extrusion amongst the common reasons for failure. Application of 3Dimensional (3D) printing may help overcome some of these barriers, however digital methods to attain accurate 3D morphological studies of ossicular anatomy are lacking, exacerbated by the limitation of resolution of clinical imaging. Methods: 20 human cadaveric temporal bones were assessed using micro computed tomography (CT) imaging to demonstrate the lowest resolution required for accurate 3D reconstruction. The bones were then scanned using conebeam CT (125 mu m) and helical CT (0.6 mm). 3D reconstruction using clinical imaging techniques with microCT imaging (40 mu m resolution) as a reference was assessed. The incus was chosen as the focus of study. Two different methods of 3D printing techniques were assessed. Results: A minimum resolution of 100 mu m was needed for adequate 3D reconstruction of the ossicular chain. Conebeam CT gave the most accurate data on 3D analysis, producing the smallest mean variation in surface topography data relative to microCT (mean difference 0.037 mm, p < 0.001). Though the incus varied in shape in between people, paired matches were identical. Thus, the contralateral side can be used for 3D printing source data if the ipsilateral incus is missing. Laser based 3D printing was superior to extrusion based printing to achieve the resolution demands for 3D printed ossicles. Conclusion: Resolution of modern imaging allows 3D reconstructions and 3D printing of human ossicles with good accuracy, though it is important to pay attention to thresholding during this process.
引用
收藏
页码:E177 / E185
页数:9
相关论文
共 50 条
  • [31] Ossiculoplasty: Revisited
    Mudhol, R. S.
    Naragund, A. I.
    Shruthi, V. S.
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2013, 65 : S451 - S454
  • [32] Precision medicine for all? Challenges and opportunities for a precision medicine approach to critical illness
    Christopher W. Seymour
    Hernando Gomez
    Chung-Chou H. Chang
    Gilles Clermont
    John A. Kellum
    Jason Kennedy
    Sachin Yende
    Derek C. Angus
    Critical Care, 21
  • [33] Revision Ossiculoplasty
    Zachary G. Schwam
    George B. Wanna
    Current Otorhinolaryngology Reports, 2019, 7 : 237 - 243
  • [34] Advances and promises of personalized precision medicine for metabolic diseases: Precision metabolic medicine
    Froguel, P.
    Bonnefond, A.
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2023, 207 (02): : 199 - 203
  • [35] Precision medicine for all? Challenges and opportunities for a precision medicine approach to critical illness
    Seymour, Christopher W.
    Gomez, Hernando
    Chang, Chung-Chou H.
    Clermont, Gilles
    Kellum, John A.
    Kennedy, Jason
    Yende, Sachin
    Angus, Derek C.
    CRITICAL CARE, 2017, 21
  • [36] Ossiculoplasty Outcome Parameter Staging Index as a Prognostic Factor in Ossiculoplasty
    Ahmed, Aftab
    Khan, Danish Ahmad
    Sharma, Satish Chandra
    INDIAN JOURNAL OF OTOLOGY, 2022, 28 (03) : 198 - 203
  • [37] Precision Medicine in Lifestyle Medicine: The Way of the Future?
    Gray, Ian D.
    Kross, Andrea R.
    Renfrew, Melanie E.
    Wood, Paul
    AMERICAN JOURNAL OF LIFESTYLE MEDICINE, 2020, 14 (02) : 169 - 186
  • [38] Precision Medicine and Personalized Medicine in Cardiovascular Disease
    Currie, Gemma
    Delles, Christian
    SEX-SPECIFIC ANALYSIS OF CARDIOVASCULAR FUNCTION, 2018, 1065 : 589 - 605
  • [39] Network Medicine: A Clinical Approach for Precision Medicine and Personalized Therapy in Coronary Heart Disease
    Infante, Teresa
    Del Viscovo, Luca
    De Rimini, Maria Luisa
    Padula, Sergio
    Caso, Pio
    Napoli, Claudio
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2020, 27 (04) : 279 - 302
  • [40] Co-Clinical Imaging Resource Program (CIRP): Bridging the Translational Divide to Advance Precision Medicine
    Shoghi, Kooresh, I
    Badea, Cristian T.
    Blocker, Stephanie J.
    Chenevert, Thomas L.
    Laforest, Richard
    Lewis, Michael T.
    Luker, Gary D.
    Manning, H. Charles
    Marcus, Daniel S.
    Mowery, Yvonne M.
    Pickup, Stephen
    Richmond, Ann
    Ross, Brian D.
    Vilgelm, Anna E.
    Yankeelov, Thomas E.
    Zhou, Rong
    TOMOGRAPHY, 2020, 6 (03) : 273 - 287