Full-scale experimental and numerical analysis of water mist system for sheltered fire sources in wind generator compartment

被引:29
作者
Chiu, Chen-Wei [1 ]
Li, Yu-Hsiu [1 ]
机构
[1] Natl Taiwan Police Coll, Dept Fire Safety, Taipei 11696, Taiwan
关键词
Full-scale fire experiments; Numerical simulations; Water mist system; Wind generators; Sheltered fire sources; FDS; COMPUTATIONAL FLUID-DYNAMICS; SUPPRESSION; SPRINKLER; FLAME;
D O I
10.1016/j.psep.2015.05.011
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Through a series of full-scale fire experiments and numerical simulations, the effectiveness of water mist system on wind generator could be estimated, and compared with fire parameters, such as exposed or unexposed fire sources, number of nozzles, un-sheltered or sheltered fire sources, and fire source location. The experimental study found that the position of the water mist nozzles and whether the flames inside the oil pan are covered have a significant influence on overall extinguishing efficacy. The water mist system proved to have sound effectiveness on fire suppression in wind generators with sheltered fire source. According to FDS simulations of water mist systems, the simulated temperature curve declined more significantly than that for the actual measurements, indicating that the cooling effect of the simulated water mist was better. However, simulations were used for a situation where water mist was unable to directly extinguish the fire. Analysis of the simulated airflow showed that an opening caused the water to discharge outwards and the airflow was disturbed by the outside; thus, the extinguishing effect was poorer. There was less water with a sheltering object, and thus the extinguishing effect was poorer. (C) 2015 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 49
页数:10
相关论文
共 19 条
[1]  
[Anonymous], 2012, 750 NFPA
[2]  
[Anonymous], FIR SAF SCI P 4 INT
[3]  
Arvidson M., 2003, VNNOVA WATER MIST RE
[4]   Investigating the burning characteristics of electric cables used in the nuclear power plant by way of 3-D transient FDS code [J].
Ferng, Y. M. ;
Liu, C. H. .
NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (01) :88-94
[5]   Investigation of appropriate mesh size and solid angle number for CFD simulating the characteristics of pool fires_with experiments assessment [J].
Ferng, Y. M. ;
Lin, C. H. .
NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (04) :816-822
[6]  
Fox R.W., 2004, INTRO FLUID MECH, VSixth
[7]   An experimental and numerical study on fire suppression using a water mist in an enclosure [J].
Kim, SC ;
Ryou, HS .
BUILDING AND ENVIRONMENT, 2003, 38 (11) :1309-1316
[8]  
Kline S.J., 1982, MECH ENG, V104, P250
[9]   Investigating the effect of computational grid sizes on the predicted characteristics of thermal radiation for a fire [J].
Lin, C. H. ;
Ferng, Y. M. ;
Hsu, W. S. .
APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) :2243-2250
[10]  
Mawhinney L.R., 1997, FIRE PROTECTION HDB