Three-dimensional microstructure of human alveolar trabecular bone: a micro-computed tomography study

被引:22
作者
Lee, Ji-Hyun [1 ]
Kim, Hee-Jin [2 ]
Yun, Jeong-Ho [1 ,3 ]
机构
[1] Chonbuk Natl Univ, Sch Dent, Dept Periodontol, 567 Baekje Daero, Jeonju 54896, South Korea
[2] Yonsei Univ, Coll Dent, Human Identificat Res Ctr, Dept Oral Biol,Div Anat & Dev Biol,PLUS Project B, Seoul, South Korea
[3] Chonbuk Natl Univ, Chonbuk Natl Univ Hosp, Biomed Res Inst, Res Inst Clin Med, Jeonju, South Korea
关键词
Cadaver; Dental implants; X-ray microtomography; POROUS TITANIUM; DENSITY; CLASSIFICATION; REGENERATION; IMPLANTS; SIZE; CT;
D O I
10.5051/jpis.2017.47.1.20
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The microstructural characteristics of trabecular bone were identified using microcomputed tomography (micro-CT), in order to develop a potential strategy for implant surface improvement to facilitate osseointegration. Methods: Alveolar bone specimens from the cadavers of 30 humans were scanned by high-resolution micro-CT and reconstructed. Volumes of interest chosen within the jaw were classified according to Hounsfield units into 4 bone quality categories. Several structural parameters were measured and statistically analyzed. Results: Alveolar bone specimens with D1 bone quality had significantly higher values for all structural parameters than the other bone quality categories, except for trabecular thickness (Tb.Th). The percentage of bone volume, trabecular separation (Tb.Sp), and trabecular number (Tb.N) varied significantly among bone quality categories. Tb. Sp varied markedly across the bone quality categories (D1:0.59 +/- 0.22 mm, D4: 1.20 +/- 0.48 mm), whereas Tb. Th had similar values (D1: 0.30 +/- 0.08 mm, D4: 0.22 +/- 0.05 mm). Conclusions: Bone quality depended on Tb. Sp and number-that is, endosteal space architecture-rather than bone surface and Tb. Th. Regardless of bone quality, Tb. Th showed little variation. These factors should be taken into account when developing individualized implant surface topographies.
引用
收藏
页码:20 / 29
页数:10
相关论文
共 27 条
[1]  
[Anonymous], 1985, TISS INT DENT OSS CL
[2]   Tissue engineered microsphere-based matrices for bone repair: design and evaluation [J].
Borden, M ;
Attawia, M ;
Khan, Y ;
Laurencin, CT .
BIOMATERIALS, 2002, 23 (02) :551-559
[3]   High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture [J].
Burghardt, Andrew J. ;
Link, Thomas M. ;
Majumdar, Sharmila .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) :2179-2193
[4]  
Drago C J, 1992, J Prosthodont, V1, P29, DOI 10.1111/j.1532-849X.1992.tb00423.x
[5]   Three-dimensional morphometric analysis of human cadaver bone: microstructural data from maxilla and mandible [J].
Fanuscu, MI ;
Chang, TL .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :213-218
[6]   Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review [J].
Ibrahim, N. ;
Parsa, A. ;
Hassan, B. ;
van der Stelt, P. ;
Wismeijer, D. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (03)
[7]  
Jemt T, 1993, Int J Oral Maxillofac Implants, V8, P635
[8]   SITE CLASSIFICATION FOR THE OSSEOINTEGRATED IMPLANT [J].
JENSEN, O .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 61 (02) :228-234
[9]   Trabecular bone mineral and calculated structure of human bone specimens scanned by peripheral quantitative computed tomography: Relation to biomechanical properties [J].
Jiang, YB ;
Zhao, JN ;
Augat, P ;
Ouyang, XL ;
Lu, Y ;
Majumdar, S ;
Genant, HK .
JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (11) :1783-1790
[10]   The three-dimensional microstructure of trabecular bone: Analysis of site-specific variation in the human jaw bone [J].
Kim, Jo-Eun ;
Shin, Jae-Myung ;
Oh, Sung-Ook ;
Yi, Won-Jin ;
Heo, Min-Suk ;
Lee, Sam-Sun ;
Choi, Soon-Chul ;
Huh, Kyung-Hoe .
IMAGING SCIENCE IN DENTISTRY, 2013, 43 (04) :227-233