Theoretical study on a modified heat pump cycle with zeotropic mixture R32/R290 for district heating in cold region

被引:31
作者
Fan, Chaochao [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Refrigerat & Cryogen Engn, Sch Energy & Power Engn, Xian 710049, Shaanxi, Peoples R China
关键词
Heat pump; District heating; Internal autocascade; Ejector; THERMODYNAMIC ANALYSIS; CLIMATE REGION; PERFORMANCE; REFRIGERATION; EFFICIENCIES;
D O I
10.1016/j.applthermaleng.2019.04.112
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper proposes an ejector enhanced internal auto-cascade heat pump cycle (EIHP) with zeotropic mixture R32/R290 for district heating in cold region. The internal auto-cascade and ejector techniques are applied for enhancing the system performance. Performances of the EIHP are investigated by using a developed thermodynamic model. The simulation results indicate that as the evaporator outlet temperature ranges -25 degrees C to 5 degrees C, EIHP yields 199% higher COP and 37-12% higher volumetric heating capacity over the conventional heat pump cycle (CHP) at a fixed condenser outlet temperature of 60 degrees C. Moreover, to evaluate the system performance in detail, the other critical parameters are investigated including condenser outlet temperature, refrigerant mass fraction of R32, ejector performance and so on. Generally, the EIHP system can obtain a significant performance enhancement for district heating applications.
引用
收藏
页码:702 / 707
页数:6
相关论文
共 21 条
[1]   Large heat pumps in Swedish district heating systems [J].
Averfalk, Helge ;
Ingvarsson, Paul ;
Persson, Urban ;
Gong, Mei ;
Werner, Sven .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 79 :1275-1284
[2]   VLE measurements and modeling for the strongly positive azeotropic R32+propane system [J].
Bobbo, S ;
Fedele, L ;
Camporese, R ;
Stryjek, R .
FLUID PHASE EQUILIBRIA, 2002, 199 (1-2) :175-183
[3]   Energy consumption modeling of air source electric heat pump water heaters [J].
Bourke, Grant ;
Bansal, Pradeep .
APPLIED THERMAL ENGINEERING, 2010, 30 (13) :1769-1774
[4]   Theoretical analysis on a new direct expansion solar assisted ejector-compression heat pump cycle for water heater [J].
Chen, Jiaheng ;
Yu, Jianlin .
SOLAR ENERGY, 2017, 142 :299-307
[5]   Progress of mathematical modeling on ejectors [J].
He, S. ;
Li, Y. ;
Wang, R. Z. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (08) :1760-1780
[6]   A combined Dual Hot-Gas Bypass Defrosting method with accumulator heater for an air-to-air heat pump in cold region [J].
Kim, Jaehong ;
Choi, Hwan-Jong ;
Kim, Kyung Chun .
APPLIED ENERGY, 2015, 147 :344-352
[7]  
Lemmon EW, 2010, NIST STANDARD REFERE, V23, P1
[8]   Study of ejector efficiencies in refrigeration cycles [J].
Liu, Fang ;
Groll, Eckhard A. .
APPLIED THERMAL ENGINEERING, 2013, 52 (02) :360-370
[9]   Oil flooded compression cycle enhancement for two-stage heat pump in cold climate region: System design and theoretical analysis [J].
Luo, Baojun .
ENERGY CONVERSION AND MANAGEMENT, 2016, 115 :52-59
[10]   Solar-assisted auto-cascade heat pump cycle with zeotropic mixture R32/R290 for small water heaters [J].
Lv, Xiaolong ;
Yan, Gang ;
Yu, Jianlin .
RENEWABLE ENERGY, 2015, 76 :167-172