Spectrophotometric, colorimetric and visually detection of Pseudomonas aeruginosa ETA gene based gold nanoparticles DNA probe and endonuclease enzyme

被引:24
作者
Amini, Bahram [1 ]
Kamali, Mehdi [2 ]
Salouti, Mojtaba [3 ]
Yaghmaei, Parichehreh [1 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch IAU, Dept Biol, Tehran, Iran
[2] Baqiyatallah Univ Med Sci, Nanobiotechnol Res Ctr, Tehran, Iran
[3] Islamic Azad Univ, Zanjan Branch, Dept Microbiol, Fac Sci, Zanjan, Iran
关键词
Pseudomonas aeruginosa; Colorimetric assay; ETA gene; Gold nanoparticles; Endonuclease; SALMONELLA SPP; AMPLIFICATION; PCR; SAMPLES;
D O I
10.1016/j.saa.2018.03.056
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Colorimetric DNA detection is preferred over other methods for clinical molecular diagnosis because it does not require expensive equipment. In the present study, the colorimetric method based on gold nanopartides (GNPs) and endonuclease enzyme was used for the detection of P. aeruginosa ETA gene. Firstly, the primers and probe for P. aeruginosa exotoxin A (ETA) gene were designed and checked for specificity by the PCR method. Then, GNPs were synthesized using the citrate reduction method and conjugated with the prepared probe to develop the new nano-biosensor. Next, the extracted target DNA of the bacteria was added to GNP-probe complex to check its efficacy for P. aeruginosa ETA gene diagnosis. A decrease in absorbance was seen when GNP-probe-target DNA cleaved into the small fragments of BamHI endonuclease due to the weakened electrostatic interaction between GNPs and the shortened DNA. The right shift of the absorbance peak from 530 to 562 nm occurred after adding the endonuclease. It was measured using a UV-VIS absorption spectroscopy that indicates the existence of the P. aeruginosa ETA gene. Sensitivity was determined in the presence of different concentrations of target DNA of P. aeruginosa. The results obtained from the optimized conditions showed that the absorbance value has linear correlation with concentration of target DNA (R: 0.9850) in the range of 10-50 ng mL(-1) with the limit detection of 9.899 ng mL(-1). Thus, the specificity of the new method for detection of P. aeruginosa was established in comparison with other bacteria. Additionally, the designed assay was quantitatively applied to detect the P. aeruginosa ETA gene from 10(3) to 10(8) CFU mL(-1) in real samples with a detection limit of 320 CFU (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:421 / 429
页数:9
相关论文
共 25 条
  • [1] Colony to colorimetry in 6 h: ELISA detection of a surface-expressed Pseudomonas aeruginosa virulence factor using immobilized bacteria
    Adawi, Azmi
    Neville, Lewis F.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 74 (01) : 84 - 87
  • [2] DNA probe based colorimetric method for detection of rifampicin resistance of Mycobacterium tuberculosis
    Adikaram, Chamila P.
    Perera, Jennifer
    Wijesundera, Sandya S.
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 96 : 92 - 98
  • [3] Fluorescence bio-barcode DNA assay based on gold and magnetic nanoparticles for detection of Exotoxin A gene sequence
    Amini, Bahram
    Kamali, Mehdi
    Salouti, Mojtaba
    Yaghmaei, Parichehreh
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 92 : 679 - 686
  • [4] Armbruster DA., 2008, CLIN BIOCHEM REV, V29, pS49, DOI DOI 10.3390/S20236922
  • [5] Asghar N., 2018, PROCESS BIOCHEM, V65, P46
  • [6] A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots
    Chen, Rui
    Huang, Xiaolin
    Li, Juan
    Shan, Shan
    Lai, Weihua
    Xiong, Yonghua
    [J]. ANALYTICA CHIMICA ACTA, 2016, 947 : 50 - 57
  • [7] Multiplex PCR and a chromogenic DNA macroarray for the detection of Listeria monocytogens, Staphylococcus aureus, Streptococcus agalactiae, Enterobacter sakazakii, Escherichia coli O157:H7, Vibrio parahaemolyticus, Salmonella spp. and Pseudomonas fluorescens in milk and meat samples
    Chiang, Yu-Cheng
    Tsen, Hau-Yang
    Chen, Hsin-Yen
    Chang, Yu-Hsin
    Lin, Chien-Ku
    Chen, Chih-Yuan
    Pai, Wan-Yu
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 88 (01) : 110 - 116
  • [8] Sensitive detection of endonuclease activity and inhibition using gold nanorods
    Deng, Jing
    Jin, Yan
    Wang, Lin
    Chen, Guozhen
    Zhang, Chengxiao
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 34 (01) : 144 - 150
  • [9] PCR and the detection of Pseudomonas aeruginosa in respiratory samples of CF patients. A literature review
    Deschaght, Pieter
    Van daele, Sabine
    De Baets, Frans
    Vaneechoutte, Mario
    [J]. JOURNAL OF CYSTIC FIBROSIS, 2011, 10 (05) : 293 - 297
  • [10] Driscoll J. A., 2007, INFECT DRUG RESIST, V67, P51