TNRT profiles with the Nucleus Research Platform 8 system

被引:12
作者
Lai, W. K. [1 ]
Dillier, N. [1 ]
Weber, B. P. [1 ]
Lenarz, T. [2 ]
Battmer, R. [2 ]
Gantz, B. [3 ]
Brown, C. [3 ]
Cohen, N. [4 ]
Waltzman, S. [4 ]
Skinner, M. [5 ]
Holden, L. [5 ]
Cowan, R. [6 ,7 ]
Busby, P. [6 ,7 ]
Killian, M. [8 ]
机构
[1] Univ Zurich Hosp, Dept Otorhinolaryngol, CH-8091 Zurich, Switzerland
[2] Hannover Med Sch, Dept Otolaryngol, Hannover, Germany
[3] Univ Iowa, Dept Otolaryngol, Iowa City, IA 52242 USA
[4] NYU, Dept Otolaryngol, Med Ctr, New York, NY 10003 USA
[5] Washington Univ, Sch Med, Dept Otolaryngol, St Louis, MO 63110 USA
[6] Cooperat Res Ctr Cochlear Implant & Hearing Aid I, Melbourne, Vic, Australia
[7] Cooperat Res Ctr Cochlear Implant & Hearing Aid I, Sydney, NSW, Australia
[8] Cochlear Technol Ctr, Mechelen, Belgium
基金
瑞士国家科学基金会;
关键词
Cochlear implant; CI24RE; Neural response telemetry; Evoked compound action potential; TNRT profile; Principal component analysis; NEURAL RESPONSE TELEMETRY; COCHLEAR IMPLANT USERS; ACTION-POTENTIAL THRESHOLDS; C-LEVELS; PROCESSOR; SPEECH; CAPABILITIES; CHILDREN; EAP; NRT;
D O I
10.1080/14992020902962413
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
This study investigates the effect of the Nucleus CI24RE implant's neural response telemetry (NRT) system. which has less internal noise compared to its predecessor, the CI24M/R implant. on the NRT threshold (TNRT) profile across the array. CI24M/R measurements were simulated by ignoring CI24RE Measurements with response amplitudes below 50 uV Comparisons of the estimated TNRTs from the CI24RE measurements and the CI24M/R simulations Suggest that, apart front a constant level difference. the TNRT profiles from the newer implant generally would not have differed very much from those of its predecessor. This view was also reflected by principal component analysis (PCA) results which revealed a 'shift' component similar to that reported by Smoorenburg et al (2002). On the whole, there is no indication that current practices of using the TNRT profiles for assisting with speech processor programming need to be revised for the CI24RE implant.
引用
收藏
页码:645 / 654
页数:10
相关论文
共 16 条
[1]  
Battmer RD, 2004, INT J AUDIOL, V43, pS10
[2]   The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: Data from adults [J].
Brown, CJ ;
Hughes, ML ;
Luk, B ;
Abbas, PJ ;
Wolaver, A ;
Gervais, J .
EAR AND HEARING, 2000, 21 (02) :151-163
[3]   Normative findings of electrically evoked compound action potential measurements uing the neural response telemetry of the nucleus CI24M cochlear implant system [J].
Dees, DC ;
Dillier, N ;
Lai, WK ;
von Wallenberg, E ;
van Dijk, B ;
Akdas, F ;
Aksit, M ;
Batman, C ;
Beynon, A ;
Burdo, S ;
Chanal, JM ;
Collet, L ;
Conway, M ;
Coudert, C ;
Craddock, L ;
Cullington, H ;
Deggouj, N ;
Fraysse, B ;
Grabel, S ;
Kiefer, J ;
Kiss, JG ;
Lenarz, T ;
Mair, A ;
Maune, S ;
Müller-Deile, J ;
Piron, JP ;
Razza, S ;
Tasche, C ;
Thai-Van, H ;
Toth, F ;
Truy, E ;
Uziel, A ;
Smoorenburg, GF .
AUDIOLOGY AND NEURO-OTOLOGY, 2005, 10 (02) :105-116
[4]   Estimation of psychophysical levels using the electrically evoked compound action potential measured with the neural response telemetry capabilities of cochlear corporation's CI24M device [J].
Franck, KH ;
Norton, SJ .
EAR AND HEARING, 2001, 22 (04) :289-299
[5]  
GORDON KA, 2002, ANN OTOL RHINOL LA S, V189, P12
[6]   Comparison of EAP thresholds with MAP levels in the nucleus 24 cochlear implant: Data from children [J].
Hughes, ML ;
Brown, CJ ;
Abbas, PJ ;
Wolaver, AA ;
Gervais, JP .
EAR AND HEARING, 2000, 21 (02) :164-174
[7]  
Kaplan-Neeman Ricky, 2004, Journal of Basic and Clinical Physiology and Pharmacology, V15, P57
[8]   Use of neural response telemetry measures to objectively set the comfort levels in the nucleus 24 cochlear implant [J].
King, John E. ;
Polak, Marek ;
Hodges, Annelle V. ;
Payne, Stacy ;
Telischi, Fred F. .
JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2006, 17 (06) :413-431
[9]  
Lai Chooi-May, 2004, Genet Vaccines Ther, V2, P3, DOI 10.1186/1479-0556-2-3
[10]   Intra-operative recordings of electrically evoked auditory nerve action potentials in young children by use of neural response telemetry with the Nucleus CI24M cochlear implant [J].
Mason, SM ;
Cope, Y ;
Garnham, J ;
O'Donoghue, GM ;
Gibbin, KP .